CoChat

Noninvasive monitoring of deterioration in skeletal muscle function with forearm cast immobilization and the prevention of deterioration

Open access
Motobe, Mayuko, Murase, Norio, Osada, Takuya, Homma, Toshiyuki, Ueda, Chihoko, Nagasawa, Takeshi, Kitahara, Aya, Ichimura, Shiro, Kurosawa, Yuko, Katsumura, Toshihito, Hoshika, Akinori, Hamaoka, Takafumi · 2004 · Dynamic Medicine
Cited by 72

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BackgroundIn this research inactivity was simulated by immobilizing the forearm region in a plaster cast. Changes in skeletal muscle oxidative function were measured using near-infrared spectroscopy (NIRS), and the preventative effect of the training protocol on deterioration of skeletal muscle and the clinical utility of NIRS were examined.MethodsFourteen healthy adult men underwent immobilization of the forearm of the non-dominant arm by plaster cast for 21 days. Eight healthy adult subjects were designated as the immobilization group (IMM) and six were designated as the immobilization + training group (IMM+TRN). Grip strength, forearm circumference and dynamic handgrip exercise endurance were measured before and after the 21-day immobilization period. Using NIRS, changes in oxidative function of skeletal muscles were also evaluated. Muscle oxygen consumption recovery was recorded after the completion of 60 seconds of 40% maximum voluntary contraction (MVC) dynamic handgrip exercise 1 repetition per 4 seconds and the recovery time constant (TcVO2mus) was calculated.ResultsTcVO2mus for the IMM was 59.7 ± 5.5 seconds (average ± standard error) before immobilization and lengthened significantly to 70.4 ± 5.4 seconds after immobilization (p < 0.05). For the IMM+TRN, TcVO2mus was 78.3 ± 6.2 seconds before immobilization and training and shortened significantly to 63.1 ± 5.6 seconds after immobilization and training (p < 0.05).ConclusionsThe training program used in this experiment was effective in preventing declines in muscle oxidative function and endurance due to immobilization. The experimental results suggest that non-invasive monitoring of skeletal muscle function by NIRS would be possible in a clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1476-5918-3-2

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Motobe, M., Murase, N., Osada, T., Homma, T., Ueda, C., Nagasawa, T., Kitahara, A., Ichimura, S., Kurosawa, Y., Katsumura, T., Hoshika, A., & Hamaoka, T.
Venue
Dynamic Medicine
Published
2004-02-06
Volume
3
Issue
1
Pages
2-2
ISSN
1476-5918 (ISSN-L)
OpenAlex
W2117946817
Cited by
72
References
8
FWCI
0.11
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.