The influence of oxygen tension on the structure and function of isolated liver sinusoidal endothelial cells
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Liver sinusoidal endothelial cells (LSECs) are specialized scavenger cells, with crucial roles in maintaining hepatic and systemic homeostasis. Under normal physiological conditions, the oxygen tension encountered in the hepatic sinusoids is in general considerably lower than the oxygen tension in the air; therefore, cultivation of freshly isolated LSECs under more physiologic conditions with regard to oxygen would expect to improve cell survival, structure and function. In this study LSECs were isolated from rats and cultured under either 5% (normoxic) or 20% (hyperoxic) oxygen tensions, and several morpho-functional features were compared. RESULTS: Cultivation of LSECs under normoxia, as opposed to hyperoxia improved the survival of LSECs and scavenger receptor-mediated endocytic activity, reduced the production of the pro-inflammatory mediator, interleukin-6 and increased the production of the anti-inflammatory cytokine, interleukin-10. On the other hand, fenestration, a characteristic feature of LSECs disappeared gradually at the same rate regardless of the oxygen tension. Expression of the cell-adhesion molecule, ICAM-1 at the cell surface was slightly more elevated in cells maintained at hyperoxia. Under normoxia, endogenous generation of hydrogen peroxide was drastically reduced whereas the production of nitric oxide was unaltered. Culture decline in high oxygen-treated cultures was abrogated by administration of catalase, indicating that the toxic effects observed in high oxygen environments is largely caused by endogenous production of hydrogen peroxide. CONCLUSION: Viability, structure and many of the essential functional characteristics of isolated LSECs are clearly better preserved when the cultures are maintained under more physiologic oxygen levels. Endogenous production of hydrogen peroxide is to a large extent responsible for the toxic effects observed in high oxygen environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regulation of Mammalian O 2 Homeostasis by Hypoxia-Inducible Factor 1
Semenza, G. L. (1999) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.15.1.551 · Cited by 1,914 · cited 1×
“Thus, hypoxic conditions (5–15 mmHg O2) are characterized by a shift to more anaerobic metabolic processes in the cells, or to the expression of signalling molecules that promote oxygen delivery, such as pro-angiogenic switches [5].”
BackgroundFormation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
Cited by
Liver sinusoidal endothelial cells: Physiology and role in liver diseases
Poisson, J., Lemoinne, S., Boulanger, C., Durand, F., Moreau, R., Valla, D., & Rautou, P.-E. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2016.07.009 · Cited by 1,047
“Fourth, in the normal liver, LSECs are exposed to an oxygen pressure decreasing along the liver lobule from 90 to 30 mmHg [66]; oxygen level is thus lower than in atmospheric conditions where oxygen pressure is 160 mmHg; actually, LSEC are particularly sensitive to hyperoxia and to the resulting oxidative stress [67];…”
BackgroundKeeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Liver Sinusoidal Endothelial Cells
Sørensen, K. K., Simon‐Santamaria, J., McCuskey, R. S., & Smedsrød, B. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140078 · Cited by 257
Self-citationThe scavenger endothelial cell: a new player in homeostasis and immunity
Sørensen, K. K., McCourt, P., Berg, T., Crossley, C., Couteur, D. L., Wake, K., & Smedsrød, B. (2012) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00686.2011 · Cited by 233
Self-citationLiver tissue engineering in the evaluation of drug safety
Dash, A., Inman, W., Hoffmaster, K., Sevidal, S., Kelly, J., Obach, R. S., Griffith, L. G., & Tannenbaum, S. R. (2009) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425250903160664 · Cited by 158
“The baseline metabolism and functions occur typically in environments ranging from 30 to 90 mmHg O2, a value significantly lower than atmospheric oxygen tension (160 mmHg O2) [141].”
Background
Metadata
- Authors
- Martinez, I., Nedredal, G. I., Øie, C. I., Warren, A., Johansen, O., Le Couteur, D. G., & Smedsrød, B.
- Venue
- Comparative Hepatology
- Published
- 2008-05-05
- Volume
- 7
- Issue
- 1
- Pages
- 4-4
- ISSN
- 1476-5926 (ISSN-L)
- OpenAlex
- W2071844086
- Cited by
- 76
- References
- 2
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.