The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Physiologic upper limit of pore size in the blood-tumor barrier of malignant solid tumors
Open accessAbstract
BACKGROUND: The existence of large pores in the blood-tumor barrier (BTB) of malignant solid tumor microvasculature makes the blood-tumor barrier more permeable to macromolecules than the endothelial barrier of most normal tissue microvasculature. The BTB of malignant solid tumors growing outside the brain, in peripheral tissues, is more permeable than that of similar tumors growing inside the brain. This has been previously attributed to the larger anatomic sizes of the pores within the BTB of peripheral tumors. Since in the physiological state in vivo a fibrous glycocalyx layer coats the pores of the BTB, it is possible that the effective physiologic pore size in the BTB of brain tumors and peripheral tumors is similar. If this were the case, then the higher permeability of the BTB of peripheral tumor would be attributable to the presence of a greater number of pores in the BTB of peripheral tumors. In this study, we probed in vivo the upper limit of pore size in the BTB of rodent malignant gliomas grown inside the brain, the orthotopic site, as well as outside the brain in temporalis skeletal muscle, the ectopic site. METHODS: Generation 5 (G5) through generation 8 (G8) polyamidoamine dendrimers were labeled with gadolinium (Gd)-diethyltriaminepentaacetic acid, an anionic MRI contrast agent. The respective Gd-dendrimer generations were visualized in vitro by scanning transmission electron microscopy. Following intravenous infusion of the respective Gd-dendrimer generations (Gd-G5, N = 6; Gd-G6, N = 6; Gd-G7, N = 5; Gd-G8, N = 5) the blood and tumor tissue pharmacokinetics of the Gd-dendrimer generations were visualized in vivo over 600 to 700 minutes by dynamic contrast-enhanced MRI. One additional animal was imaged in each Gd-dendrimer generation group for 175 minutes under continuous anesthesia for the creation of voxel-by-voxel Gd concentration maps. RESULTS: The estimated diameters of Gd-G7 dendrimers were 11 +/- 1 nm and those of Gd-G8 dendrimers were 13 +/- 1 nm. The BTB of ectopic RG-2 gliomas was more permeable than the BTB of orthotopic RG-2 gliomas to all Gd-dendrimer generations except for Gd-G8. The BTB of both ectopic RG-2 gliomas and orthotopic RG-2 gliomas was not permeable to Gd-G8 dendrimers. CONCLUSION: The physiologic upper limit of pore size in the BTB of malignant solid tumor microvasculature is approximately 12 nanometers. In the physiologic state in vivo the luminal fibrous glycocalyx of the BTB of malignant brain tumor and peripheral tumors is the primary impediment to the effective transvascular transport of particles across the BTB of malignant solid tumor microvasculature independent of tumor host site. The higher permeability of malignant peripheral tumor microvasculature to macromolecules smaller than approximately 12 nm in diameter is attributable to the presence of a greater number of pores underlying the glycocalyx of the BTB of malignant peripheral tumor microvasculature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Cited by
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Polymeric Nanostructures for Imaging and Therapy
Elsabahy, M., Heo, G. S., Lim, S.-M., Sun, G., & Wooley, K. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00135 · Cited by 508
Black, K. C. L., Wang, Y., Luehmann, H. P., Cai, X., Xing, W., Pang, B., Zhao, Y., Cutler, C. S., Wang, L. V., Liu, Y., et al. (2014) · ACS Nano · doi:10.1021/nn406258m · Cited by 365
Dendrimer-Based Drug Delivery Systems for Brain Targeting
Zhu, Y., Liu, C., & Pang, Z. (2019) · Biomolecules · doi:10.3390/biom9120790 · Cited by 220
Tumor-Vasculature-on-a-Chip for Investigating Nanoparticle Extravasation and Tumor Accumulation
Wang, H.-F., Ran, R., Liu, Y., Hui, Y., Zeng, B., Chen, D., Weitz, D. A., & Zhao, C.-X. (2018) · ACS Nano · doi:10.1021/acsnano.8b06846 · Cited by 161
Metadata
- Authors
- Sarin, H., Kanevsky, A. S., Wu, H., Sousa, A. A., Wilson, C. M., Aronova, M. A., Griffiths, G. L., Leapman, R. D., & Vo, H. Q.
- Venue
- Journal of Translational Medicine
- Published
- 2009-06-23
- Volume
- 7
- Issue
- 1
- Pages
- 51-51
- ISSN
- 1479-5876 (ISSN-L)
- OpenAlex
- W2079784321
- Cited by
- 169
- References
- 2
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiologic upper limit of pore size in the blood-tumor barrier of malignant solid tumors. https://app.cochat.ai/papers/10.1186/1479-5876-7-51
- The paper
- Sarin, H., Kanevsky, A. S., Wu, H., Sousa, A. A., Wilson, C. M., Aronova, M. A., Griffiths, G. L., Leapman, R. D., & Vo, H. Q. (2009). Physiologic upper limit of pore size in the blood-tumor barrier of malignant solid tumors. Journal of Translational Medicine. https://doi.org/10.1186/1479-5876-7-51
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.