Myocardial tissue tagging with cardiovascular magnetic resonance
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Cardiovascular magnetic resonance (CMR) is currently the gold standard for assessing both global and regional myocardial function. New tools for quantifying regional function have been recently developed to characterize early myocardial dysfunction in order to improve the identification and management of individuals at risk for heart failure. Of particular interest is CMR myocardial tagging, a non-invasive technique for assessing regional function that provides a detailed and comprehensive examination of intra-myocardial motion and deformation. Given the current advances in gradient technology, image reconstruction techniques, and data analysis algorithms, CMR myocardial tagging has become the reference modality for evaluating multidimensional strain evolution in the human heart. This review presents an in depth discussion on the current clinical applications of CMR myocardial tagging and the increasingly important role of this technique for assessing subclinical myocardial dysfunction in the setting of a wide variety of myocardial disease processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 4×
“SENSE is the most widespread parallel imaging technique.”
InfluentialWriting Group Members, Rosamond, W., Flegal, K., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S. M., Ho, M., Howard, V., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.187998 · Cited by 3,711
Hypertrophic Cardiomyopathy: A Systematic Review
Maron, B. J. (2002) · JAMA · doi:10.1001/jama.287.10.1308 · Cited by 2,224 · cited 1×
“Underlying histological changes include myofibrillar disarray and abnormal intramural coronary vasculature [63].”
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142 · cited 2×
“Recently, parallel imaging techniques, such as simultaneous acquisition of spatial harmonics (SMASH) [13] and sensitivity encoding (SENSE) [14] have been proposed for speeding up the image acquisition.”
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430 · cited 1×
“[7] introduced a magnetic resonance based noninvasive imaging method for tracking myocardial motion: myocardial tissue tagging.”
Noninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252 · cited 1×
“Doppler imaging [3]and Speckle tracking [4] are two novel echocardiographic techniques that have been introduced for strain quantification.”
Self-citationMR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150 · cited 2×
“Axel L, Dougherty L: MR imaging of motion with spatial modulation of magnetization.”
Nelson, G. S., Berger, R. D., Fetics, B. J., Talbot, M., Spinelli, J. C., Hare, J. M., & Kass, D. A. (2000) · Circulation · doi:10.1161/01.cir.102.25.3053 · Cited by 758 · cited 1×
“Moreover, several additional metrics have been derived [72-74] and employed to determine the optimal LV pacing region for CRT [75] and predict the response to therapy.”
Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging
Osman, N. F., Kerwin, W. S., McVeigh, E. R., & Prince, J. L. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1048::aid-mrm9>3.0.co;2-m · Cited by 588 · cited 1×
“Motion quantification techniques are divided into: a) differential optical flow-based methods that track motion by assessment of the temporal and spatial changes of image intensity; b) tag segmentation methods based on tracking of tag lines as in Findtags [15] and SPAMMVU [16] analysis; and, c) phase-based analysis me…”
MethodSelf-citationEdvardsen, T., Gerber, B. L., Garot, J., Bluemke, D. A., Lima, J. A. C., & Smiseth, O. A. (2002) · Circulation · doi:10.1161/01.cir.0000019907.77526.75 · Cited by 523 · cited 1×
“Currently, cardiovascular magnetic resonance (CMR) tagging remains the reference standard for assessment of regional function [5].”
Self-citation
Cited by
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Self-citationKawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Self-citationDrafts, B. C., Twomley, K. M., D'Agostino, R., Lawrence, J., Avis, N., Ellis, L. R., Thohan, V., Jordan, J., Melin, S. A., Torti, F. M., et al. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.11.017 · Cited by 391
Peng, P., Lekadir, K., Gooya, A., Shao, L., Petersen, S. E., & Frangi, A. F. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0521-4 · Cited by 281
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
Smiseth, O. A., Rider, O., Cvijic, M., Valkovič, L., Remme, E. W., & Voigt, J.-U. (2025) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2024.07.011 · Cited by 231
Schuster, A., Kutty, S., Padiyath, A., Parish, V., Gribben, P., Danford, D. A., Makowski, M. R., Bigalke, B., Beerbaum, P., & Nagel, E. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-58 · Cited by 158
Metadata
- Authors
- Shehata, M. L., Cheng, S., Osman, N. F., Bluemke, D. A., & Lima, J. A.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2009-01
- Volume
- 11
- Issue
- 1
- Pages
- 55
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2103725003
- Cited by
- 193
- References
- 59
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.