Cardiovascular magnetic resonance myocardial feature tracking detects quantitative wall motion during dobutamine stress
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Dobutamine stress cardiovascular magnetic resonance (DS-CMR) is an established tool to assess hibernating myocardium and ischemia. Analysis is typically based on visual assessment with considerable operator dependency. CMR myocardial feature tracking (CMR-FT) is a recently introduced technique for tissue voxel motion tracking on standard steady-state free precession (SSFP) images to derive circumferential and radial myocardial mechanics.We sought to determine the feasibility and reproducibility of CMR-FT for quantitative wall motion assessment during intermediate dose DS-CMR. METHODS: 10 healthy subjects were studied at 1.5 Tesla. Myocardial strain parameters were derived from SSFP cine images using dedicated CMR-FT software (Diogenes MRI prototype; Tomtec; Germany). Right ventricular (RV) and left ventricular (LV) longitudinal strain (EllRV and EllLV) and LV long-axis radial strain (ErrLAX) were derived from a 4-chamber view at rest. LV short-axis circumferential strain (EccSAX) and ErrSAX; LV ejection fraction (EF) and volumes were analyzed at rest and during dobutamine stress (10 and 20 μg · kg⁻¹· min⁻¹). RESULTS: In all volunteers strain parameters could be derived from the SSFP images at rest and stress. EccSAX values showed significantly increased contraction with DSMR (rest: -24.1 ± 6.7; 10 μg: -32.7 ± 11.4; 20 μg: -39.2 ± 15.2; p < 0.05). ErrSAX increased significantly with dobutamine (rest: 19.6 ± 14.6; 10 μg: 31.8 ± 20.9; 20 μg: 42.4 ± 25.5; p < 0.05). In parallel with these changes; EF increased significantly with dobutamine (rest: 56.9 ± 4.4%; 10 μg: 70.7 ± 8.1; 20 μg: 76.8 ± 4.6; p < 0.05). Observer variability was best for LV circumferential strain (EccSAX ) and worst for RV longitudinal strain (EllRV) as determined by 95% confidence intervals of the difference. CONCLUSIONS: CMR-FT reliably detects quantitative wall motion and strain derived from SSFP cine imaging that corresponds to inotropic stimulation. The current implementation may need improvement to reduce observer-induced variance. Within a given CMR lab; this novel technique holds promise of easy and fast quantification of wall mechanics and strain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430 · cited 1×
“Deformation assessment of tagged lines within the myocardium may overcome these limitations however requires acquisition of additional tagging sequences and post processing [3].”
BackgroundStanton, T., Leano, R., & Marwick, T. H. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.862334 · Cited by 924 · cited 1×
“Stanton and colleagues demonstrated that automated echocardiography speckle-tracking derived global EllLV is a superior predictor of outcome compared to either EF or wall motion score index; and suggested that EllLV may even become the optimal method to assess global left ventricular systolic function [23].”
MethodNagel, E., Lehmkuhl, H. B., Bocksch, W., Klein, C., Vogel, U., Frantz, E., Ellmer, A., Dreysse, S., & Fleck, E. (1999) · Circulation · doi:10.1161/01.cir.99.6.763 · Cited by 792 · cited 1×
“Dobutamine stress imaging was performed as previously described [7].”
MethodSelf-citationHudsmith†, L., Petersen†, S., Francis, J., Robson, M., & Neubauer, S. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500295516 · Cited by 627
Assessment of Passive Elastic Stiffness for Isolated Heart Muscle and the Intact Heart
MIRSKY, I., & PARMLEY, W. W. (1973) · Circulation Research · doi:10.1161/01.res.33.2.233 · Cited by 400 · cited 2×
“Natural radial strain values were calculated according to the following equation: loge (ESWT/EDWT) as previously validated [10].”
MethodResultHor, K. N., Gottliebson, W. M., Carson, C., Wash, E., Cnota, J., Fleck, R., Wansapura, J., Klimeczek, P., Al-Khalidi, H. R., Chung, E. S., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.006 · Cited by 379 · cited 2×
“Hor et al have recently shown that CMR-FT provides similar results compared to HARP myocardial tagging in a patient population with Duchenne muscular dystrophy [5].”
BackgroundResultIbrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Myocardial tissue tagging with cardiovascular magnetic resonance
Shehata, M. L., Cheng, S., Osman, N. F., Bluemke, D. A., & Lima, J. A. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-55 · Cited by 193
Kuijpers, D., Ho, K. Y. J. A. M., van Dijkman, P. R. M., Vliegenthart, R., & Oudkerk, M. (2003) · Circulation · doi:10.1161/01.cir.0000060544.41744.7c · Cited by 164 · cited 1×
“Adding quantitative analysis to DS-CMR in CAD may not only increase diagnostic accuracy as compared to visual analysis for the detection of ischemia during high-dose dobutamine stress [17] but may also detect quantitative changes in myocardial strain already detectable at lower stress levels; thereby increasing feasib…”
MethodMaret, E., Tödt, T., Brudin, L. H., Nylander, E., Swahn, E., Ohlsson, J. L., & Engvall, J. E. (2009) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-7-53 · Cited by 142
Thiele, H., Paetsch, I., Schnackenburg, B., Bornstedt, A., Grebe, O. C., Wellnhofer, E., Schuler, G. C., Fleck, E., & Nagel, E. C. (2002) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120013298 · Cited by 134
Self-citationSchuster, A., Paul, M., Bettencourt, N., Morton, G., Chiribiri, A., Ishida, M., Hussain, S. T., Jogiya, R., Kutty, S., Bigalke, B., et al. (2011) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.10.137 · Cited by 125 · cited 1×
“CMR-FT is also useful for the assessment of myocardial viability [19].”
BackgroundSelf-citationBansal, M., Jeffriess, L., Leano, R., Mundy, J. A., & Marwick, T. H. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2009.09.025 · Cited by 104 · cited 1×
“This has also been reported by echocardiography based speckle tracking studies and our results are similar [21].”
ResultBeerbaum, P., Barth, P., Kropf, S., Sarikouch, S., Kelter‐Klöpping, A., Franke, D., Gutberlet, M., & Kühne, T. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21948 · Cited by 95 · cited 1×
“This might also be explained by difficulties in endocardial tracking due to difficulty in accurately following the tricuspid valve annulus motion with the CMR-FT software; and RV trabeculations that also lead to greater variability in RV volumetric assessment [22].”
BackgroundSelf-citationMorton, G., Schuster, A., Perera, D., & Nagel, E. C. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq256 · Cited by 44 · cited 1×
“It has evolved into a comprehensive clinical tool with the unique capability of assessing myocardial function; viability and perfusion in a single examination [1].”
BackgroundSelf-citation
Cited by
Tissue Tracking Technology for Assessing Cardiac Mechanics
Claus, P., Omar, A. M. S., Pedrizzetti, G., Sengupta, P. P., & Nagel, E. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.11.001 · Cited by 439
Self-citationStrain imaging using cardiac magnetic resonance
Scatteia, A., Baritussio, A., & Bucciarelli-Ducci, C. (2017) · Heart Failure Reviews · doi:10.1007/s10741-017-9621-8 · Cited by 366
Augustine, D., Lewandowski, A. J., Lazdam, M., Rai, A., Francis, J., Myerson, S., Noble, A., Becher, H., Neubauer, S., Petersen, S. E., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-8 · Cited by 285
Kowallick, J. T., Kutty, S., Edelmann, F., Chiribiri, A., Villa, A., Steinmetz, M., Sohns, J. M., Staab, W., Bettencourt, N., Unterberg-Buchwald, C., et al. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0060-6 · Cited by 264
Self-citationBuss, S. J., Breuninger, K., Lehrke, S., Voss, A., Galuschky, C., Lossnitzer, D., Andre, F., Ehlermann, P., Franke, J., Taeger, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jeu181 · Cited by 262
Metadata
- Authors
- Schuster, A., Kutty, S., Padiyath, A., Parish, V., Gribben, P., Danford, D. A., Makowski, M. R., Bigalke, B., Beerbaum, P., & Nagel, E.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 13
- Issue
- 1
- Pages
- 58
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2111840618
- Cited by
- 158
- References
- 18
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.