Cardiovascular magnetic resonance physics for clinicians: part II
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques which create images that represent the phase of the MR signal rather than the magnitude. It is shown how this principle can be used to generate velocity maps by designing gradient waveforms that give rise to a relative phase change that is proportional to velocity. Choice of velocity encoding range and key pitfalls in the use of this technique are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306 · cited 1×
“It has been extensively validated, both in animal models and in clinical studies [68-70].”
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581 · cited 1×
“This contrast agent is used in two of the key CMR applications for the imaging of ischaemic heart disease; myocardial perfusion imaging [15,16] and late gadolinium enhancement (LGE) imaging [17,18].”
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081 · cited 1×
“The turbo or fast spin echo pulse sequence [20, 21] generates multiple echoes by applying multiple 180o pulses after the initial 90o pulse (Figure 22).”
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
The “no-reflow” phenomenon after temporary coronary occlusion in the dog
Kloner, R. A., Ganote, C. E., & Jennings, R. B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107898 · Cited by 1,842 · cited 1×
“MVO is also known as the no-reflow phenomenon [74] and its presence serves as a significant negative predictor of functional recovery post percutaneous coronary intervention (PCI).”
Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
Anderson, L. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2822 · Cited by 1,682 · cited 1×
“For T2*-weighted gradient echo, the image contrast is strongly influenced by the presence of magnetic susceptibility effects and can be used to detect the presence of iron, for example where there is haemorrhage or iron loading of tissue [14].”
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,400 · cited 1×
“This renders the gadolinium safe for in-vivo use in most circumstances although gadoliniumbased contrast agents are contraindicated for use in patients with impaired renal function due to their association with nephrogenic systemic fibrosis (NSF) [39-41].”
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja50215 · Cited by 1,358 · cited 1×
“This contrast agent is used in two of the key CMR applications for the imaging of ischaemic heart disease; myocardial perfusion imaging [15,16] and late gadolinium enhancement (LGE) imaging [17,18].”
MR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150 · cited 2×
“In addition, it is possible to assess intra-myocardial motion by ‘tagging’ the myocardium at end diastole with a line or grid pattern, which then deforms as the heart wall contracts [37].”
Cited by
Coronary microvascular dysfunction: mechanisms and functional assessment
Camici, P. G., d'Amati, G., & Rimoldi, O. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.160 · Cited by 498
T1 Mapping in Characterizing Myocardial Disease: A Comprehensive Review
Puntmann, V. O., Peker, E., Chandrashekhar, Y., & Nagel, E. (2016) · Circulation Research · doi:10.1161/circresaha.116.307974 · Cited by 337
Magnetic Nanomaterials as Contrast Agents for MRI
Caspani, S., Magalhães, R., Araújo, J. P., & Sousa, C. T. (2020) · Materials · doi:10.3390/ma13112586 · Cited by 229
Cardiovascular magnetic resonance artefacts
Ferreira, P. F., Gatehouse, P. D., Mohiaddin, R. H., & Firmin, D. N. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-41 · Cited by 191
“Also, alternatives to these sections are available elsewhere such as the excellent physics articles from Ridgway and Biglands in JCMR 2010 and 2012 [4,5].”
BackgroundRole of Cardiovascular Imaging in the Follow-Up of Patients with Fontan Circulation
Moscatelli, S., Borrelli, N., Sabatino, J., Leo, I., Avesani, M., Montanaro, C., & Di Salvo, G. (2022) · Children · doi:10.3390/children9121875 · Cited by 21
Metadata
- Authors
- Biglands, J. D., Radjenovic, A., & Ridgway, J. P.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 14
- Issue
- 1
- Pages
- 78
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2122678409
- Cited by
- 241
- References
- 84
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.