Cardiovascular magnetic resonance physics for clinicians: part II
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques which create images that represent the phase of the MR signal rather than the magnitude. It is shown how this principle can be used to generate velocity maps by designing gradient waveforms that give rise to a relative phase change that is proportional to velocity. Choice of velocity encoding range and key pitfalls in the use of this technique are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306 · cited 1×
“It has been extensively validated, both in animal models and in clinical studies [68-70].”
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581 · cited 1×
“This contrast agent is used in two of the key CMR applications for the imaging of ischaemic heart disease; myocardial perfusion imaging [15,16] and late gadolinium enhancement (LGE) imaging [17,18].”
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081 · cited 1×
“The turbo or fast spin echo pulse sequence [20, 21] generates multiple echoes by applying multiple 180o pulses after the initial 90o pulse (Figure 22).”
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
The “no-reflow” phenomenon after temporary coronary occlusion in the dog
Kloner, R. A., Ganote, C. E., & Jennings, R. B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107898 · Cited by 1,842 · cited 1×
“MVO is also known as the no-reflow phenomenon [74] and its presence serves as a significant negative predictor of functional recovery post percutaneous coronary intervention (PCI).”
Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
Anderson, L. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2822 · Cited by 1,682 · cited 1×
“For T2*-weighted gradient echo, the image contrast is strongly influenced by the presence of magnetic susceptibility effects and can be used to detect the presence of iron, for example where there is haemorrhage or iron loading of tissue [14].”
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,400 · cited 1×
“This renders the gadolinium safe for in-vivo use in most circumstances although gadoliniumbased contrast agents are contraindicated for use in patients with impaired renal function due to their association with nephrogenic systemic fibrosis (NSF) [39-41].”
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja50215 · Cited by 1,358 · cited 1×
“This contrast agent is used in two of the key CMR applications for the imaging of ischaemic heart disease; myocardial perfusion imaging [15,16] and late gadolinium enhancement (LGE) imaging [17,18].”
MR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150 · cited 2×
“In addition, it is possible to assess intra-myocardial motion by ‘tagging’ the myocardium at end diastole with a line or grid pattern, which then deforms as the heart wall contracts [37].”
Greenwood, J. P., Maredia, N., Younger, J. F., Brown, J. M., Nixon, J., Everett, C. C., Bijsterveld, P., Ridgway, J. P., Radjenovic, A., Dickinson, C. J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61335-4 · Cited by 1,114 · cited 1×
“Myocardial perfusion imaging assesses the blood supply to the myocardium and plays an increasing role in the diagnosis of ischemic heart disease [43].”
Self-citation1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Delayed enhancement cardiovascular magnetic resonance assessment of non-ischaemic cardiomyopathies
Mahrholdt, H., Wagner, A., Judd, R. M., Sechtem, U., & Kim, R. J. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi258 · Cited by 914
Gadolinium-enhanced MR aortography.
Prince, M. R. (1994) · Radiology · doi:10.1148/radiology.191.1.8134563 · Cited by 884 · cited 1×
“By making some assumptions about the physiology of the patient and that the contrast agent mixes evenly with the blood pool during the first pass stage, it is possible to estimate how mixing with the blood pool affects concentration of the contrast medium in the arterial system during the first pass for a given inject…”
Time‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
ACR Guidance Document for Safe MR Practices: 2007
Kanal, E., Barkovich, A. J., Bell, C., Borgstede, J. P., Bradley, W. G., Froelich, J. W., Gilk, T., Gimbel, J. R., Gosbee, J., Kuhni-Kaminski, E., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1616 · Cited by 787
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Principles and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714 · cited 2×
“However, if the magnetic field is not uniform, the transverse magnetisation from different TRs can destructively cancel rather than add together in areas of magnetic field inhomogeneity, making the SSFP technique prone to dark banding artefacts across the image [16].”
Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Nagel, E. C., Klein, C., Paetsch, I., Hettwer, S., Schnackenburg, B., Wegscheider, K., & Fleck, E. (2003) · Circulation · doi:10.1161/01.cir.0000080915.35024.a9 · Cited by 683 · cited 2×
“Semi-quantitative analysis uses a specific property of the time-intensity curve, such as peak height or maximum upslope, as an index of MBF and has been shown to be diagnostically effective [54,55].”
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Lotz, J., Meier, C., Leppert, A., & Galanski, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.3.g02ma11651 · Cited by 673 · cited 5×
“This sensitivity arises due to the motion of spins within the flowing blood along the magnetic field gradients that are applied as part of the gradient echo pulse sequence [23,106].”
InfluentialSchwitter, J., Nanz, D., Kneifel, S., Bertschinger, K., Büchi, M., Knüsel, P. R., Marincek, B., Lüscher, T. F., & von Schulthess, G. K. (2001) · Circulation · doi:10.1161/01.cir.103.18.2230 · Cited by 663 · cited 2×
“Semi-quantitative analysis uses a specific property of the time-intensity curve, such as peak height or maximum upslope, as an index of MBF and has been shown to be diagnostically effective [54,55].”
Kim, R. J., Chen, E.-L., Lima, J. A. C., & Judd, R. M. (1996) · Circulation · doi:10.1161/01.cir.94.12.3318 · Cited by 662 · cited 1×
“The low values of T1 may further be maintained by the slow washout kinetics [76].”
Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597 · cited 2×
“The addition of more rf pulses and modulating gradients makes the line pattern sharper [38].”
"Black blood" T2-weighted inversion-recovery MR imaging of the heart.
Simonetti, O. P., Finn, J. P., White, R. D., Laub, G., & Henry, D. A. (1996) · Radiology · doi:10.1148/radiology.199.1.8633172 · Cited by 560
Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography
Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030614 · Cited by 499 · cited 1×
“The basic principle behind CE-MRA is essentially the same as that of conventional x-ray angiography: A bolus of contrast medium is injected intravenously and imaging is performed during the first passage of the bolus through the vessels of interest [86,87].”
gadolinium-enchanced MR aortography.
Kumar, P. (1994) · Radiology · Cited by 495
Fat Suppression in MR Imaging: Techniques and Pitfalls
Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A. (1999) · RadioGraphics · doi:10.1148/radiographics.19.2.g99mr03373 · Cited by 487 · cited 16×
“It is therefore more common to combine the STIR technique with fast or turbo spin echo pulse sequences in order to reduce the acquisition time to acceptable limits and this technique is often referred to as turboSTIR.”
InfluentialMR imaging: clinical use of the inversion recovery sequence.
Bydder, G. M., & YOUNG, I. R. (1985) · PubMed · Cited by 477
Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State Precession
Carr, J. C., Simonetti, O., Bundy, J., Li, D., Pereles, S., & Finn, J. P. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn44828 · Cited by 468 · cited 1×
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
MR Imaging: Clinical Use of the Inversion Recovery Sequence
Bydder, G. M., & Young, I. R. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198507010-00002 · Cited by 426 · cited 15×
“It is therefore more common to combine the STIR technique with fast or turbo spin echo pulse sequences in order to reduce the acquisition time to acceptable limits and this technique is often referred to as turboSTIR.”
InfluentialImproved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407 · cited 7×
“The signal intensity on PCA images is related to velocity.”
InfluentialRapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 381 · cited 1×
“The use of a low flip angle is important for spoiled gradient echo techniques [12, 13] as it allows the TR to be reduced to much lower values than”
Barkhausen, J., Ruehm, S. G., Goyen, M., Buck, T., Laub, G., & Debatin, J. F. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap12264 · Cited by 380 · cited 1×
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
MR fluoroscopy: Technical feasibility
Riederer, S. J., Tasciyan, T., Farzaneh, F., Lee, J. N., Wright, R. C., & Herfkens, R. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080102 · Cited by 370
Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Sourbron, S. P., & Buckley, D. L. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/r1 · Cited by 361 · cited 9×
“Choice of acquisition pulse sequence In DCE-MRI the image appearance changes significantly between contiguous frames due to the passage of the contrast agent through the heart so multi-shot k-space imaging strategies that fill k-space over multiple cardiac cycles [1] are not applicable.”
InfluentialDirect Cardiac NMR Imaging of Heart Wall and Blood Flow Velocity
van Dijk, P. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198406000-00012 · Cited by 343
Cardiovascular Magnetic Resonance
Pennell, D. J. (2010) · Circulation · doi:10.1161/circulationaha.108.811547 · Cited by 338
Cardiovascular Magnetic Resonance in Patients With Myocardial Infarction
Kim, H. W., Farzaneh-Far, A., & Kim, R. J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.059 · Cited by 338
Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
Gatehouse, P. D., Keegan, J., Crowe, L. A., Masood, S., Mohiaddin, R. H., Kreitner, K.-F., & Firmin, D. N. (2005) · European Radiology · doi:10.1007/s00330-005-2829-3 · Cited by 331 · cited 4×
“More detailed considerations relating to acquisition and analysis of velocity-encoded cine MR image data is beyond the scope of this review but are covered elsewhere [23,24,105].”
InfluentialStuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320 · cited 3×
“The most common approach, performed with the patient free-breathing and using navigator echoes for gating of the respiratory cycle [20,21], is described in detail.”
Cardiac SSFP imaging at 3 Tesla
Schär, M., Kozerke, S., Fischer, S. E., & Boesiger, P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20024 · Cited by 307 · cited 1×
“- 40 possible [35-37].”
Spoiling of transverse magnetization in steady‐state sequences
Zur, Y., Wood, M. L., & Neuringer, L. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210210 · Cited by 306 · cited 1×
“In spoiled gradient echo, this signal is de-phased (or spoiled) either using a spoiler gradient at the end of each TR period, or by using a technique known as rf spoiling [11] so that its contribution to subsequent TR periods is suppressed.”
Factors influencing contrast in fast spin-echo MR imaging
Constable, R. T., Anderson, A. W., Zhong, J., & Gore, J. C. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90001-g · Cited by 304 · cited 2×
“Rapidly repeated rf pulses, such as those used in turbo or fast spin echo techniques, can have the effect of reducing J-coupling, resulting in an increased T2 relaxation time and higher signal intensity from fat [6].”
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Parallel MR Imaging: A User’s Guide
Glockner, J. F., Hu, P., Stanley, D. W., Angelos, L., & King, K. (2005) · Radiographics · doi:10.1148/rg.255045202 · Cited by 269
Evaluation of left ventricular volume and mass with breath-hold cine MR imaging.
Sakuma, H., Fujita, N., Foo, T. K., Caputo, G. R., Nelson, S. J., Hartiala, J., Shimakawa, A., & Higgins, C. B. (1993) · Radiology · doi:10.1148/radiology.188.2.8327681 · Cited by 262 · cited 1×
“This is known as segmented k-space gradient echo imaging, as k-space is segmented into a series of groups of lines [28, 29], and is sometimes referred to as multiple shot imaging.”
Plein, S., Bloomer, T. N., Ridgway, J. P., Jones, T. R., Bainbridge, G. J., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1178 · Cited by 257
Self-citationGerber, B. L., Raman, S. V., Nayak, K., Epstein, F. H., Ferreira, P., Axel, L., & Kraitchman, D. L. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-18 · Cited by 219 · cited 4×
“For a comprehensive and highly informative review of the causes of DRAs see [16].”
InfluentialThiele, H., Nagel, E., Paetsch, I., Schnackenburg, B., Bornstedt, A., Kouwenhoven, M., Wahl, A., Schuler, G., & Fleck, E. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1195 · Cited by 218 · cited 1×
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
Magnetic resonance angiography: current status and future directions
Hartung, M. P., Grist, T. M., & François, C. J. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-19 · Cited by 213 · cited 5×
“Non-contrast-enhanced MRA (NCE-MRA) techniques rely on changes in the MR signal that are caused by the motion of blood through or within the image plane.”
InfluentialSakuma, H., Ichikawa, Y., Suzawa, N., Hirano, T., Makino, K., Koyama, N., CAUTEREN, M. V., & Takeda, K. (2005) · Radiology · doi:10.1148/radiol.2371040830 · Cited by 207 · cited 1×
“Coronary MRA may be performed either using two targeted thin volumes to separately cover the left and right coronary artery systems [20], or to acquire a much larger single 3D volume acquisition of the whole heart, from which reconstructed views of each artery are obtained [103].”
Analysis of myocardial perfusion MRI
Jerosch‐Herold, M., Seethamraju, R. T., Swingen, C. M., Wilke, N. M., & Stillman, A. E. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20065 · Cited by 198 · cited 1×
“Methods for quantitative analysis of perfusion data have been reviewed in detail elsewhere [51,57].”
Myocardial tissue tagging with cardiovascular magnetic resonance
Shehata, M. L., Cheng, S., Osman, N. F., Bluemke, D. A., & Lima, J. A. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-55 · Cited by 193
Bogaert, J. G., Muthurangu, V., Taylor, A. M., & Dymarkowski, S. (2012) · Medical radiology · doi:10.1007/978-3-642-23035-6 · Cited by 185
Bellon, E., Haacke, E., Coleman, P., Sacco, D., Steiger, D., & Gangarosa, R. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.147.6.1271 · Cited by 174
Suspected multiple sclerosis: MR imaging with a thin-section fast FLAIR pulse sequence.
Hashemi, R. H., Bradley, W. G., Chen, D. Y., Jordan, J. E., Queralt, J. A., Cheng, A. E., & Henrie, J. N. (1995) · Radiology · doi:10.1148/radiology.196.2.7617868 · Cited by 174 · cited 3×
“For non-cardiac applications, the two most common instances of the inversion recovery technique are Short TI Inversion Recovery (STIR) [33,34] with the TI chosen to correspond to the null point for fat tissue (Figure 3a), thus resulting in the suppression of signal from fat, and Fluid Attenuated Inversion Recovery (FL…”
An Image-based Approach to Understanding the Physics of MR Artifacts
Morelli, J. N., Runge, V. M., Ai, F., Attenberger, U., Vu, L., Schmeets, S. H., Nitz, W. R., & Kirsch, J. E. (2011) · RadioGraphics · doi:10.1148/rg.313105115 · Cited by 171 · cited 1×
“Explanations of these artefacts are given elsewhere [48,49].”
Implications of SENSE MR in routine clinical practice
van den Brink, J. S., Watanabe, Y., Kuhl, C. K., Chung, T., Muthupillai, R., Van Cauteren, M., Yamada, K., Dymarkowski, S., Bogaert, J., Maki, J. H., et al. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00333-9 · Cited by 160
Lee, V. S., Resnick, D. K., Bundy, J. M., Simonetti, O. P., Lee, P., & Weinreb, J. C. (2002) · Radiology · doi:10.1148/radiol.2223011156 · Cited by 156 · cited 2×
“‘Real-Time’ imaging is achieved by selecting a very high turbofactor [24-27], such that the whole image acquisition is completed in a single cardiac phase in a single heart beat (a single-shot acquisition).”
Mezrich, R. S. (1995) · Radiology · doi:10.1148/radiology.195.2.7724743 · Cited by 154
Paschal, C. B., & Morris, H. D. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10451 · Cited by 146 · cited 2×
“Some of these techniques have been in long-standing widespread use, such as the reduction of image acquisition matrix size and/or field of view in the phase encoding direction [25,26] and the acquisition of data for only just over half of k-space, exploiting the symmetry property of k-space [25,27].”
Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISP
Schreiber, W., Schmitt, M., Kalden, P., Mohrs, O. K., Kreitner, K., & THELEN, M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10209 · Cited by 134 · cited 2×
“They differ from genuine hypoperfusion events in that they typically last only a few heart beats [64] and they can cause the myocardial signal intensity to drop below the baseline (pre-contrast) signal value [65].”
Quantification of left ventricular function with magnetic resonance images acquired in real time
Setser, R. M., Fischer, S., & Lorenz, C. H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200009)12:3<430::aid-jmri8>3.0.co;2-v · Cited by 122
Wagner, S., Auffermann, W., Buser, P. T., Lim, T., Kircher, B. J., Pflugfelder, P. W., & Higgins, C. B. (1989) · American Heart Journal · doi:10.1016/0002-8703(89)90590-5 · Cited by 115 · cited 1×
“Outside the jet there is only a small range of v often qualitatively related to the size and severity of the flow jet and is sometimes used to grade the severity of regurgitation [107].”
Mather, A. N., Lockie, T., Nagel, E. C., Marber, M. S., Perera, D., Redwood, S. R., Radjenovic, A., Saha, A., Greenwood, J. P., & Plein, S. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-33 · Cited by 108 · cited 1×
“In MVO, T1 values may continue to decrease, as the areas occupied by MVO may receive contrast agent via passive diffusion from the neighbouring scar [77].”
Self-citationBody and Cardiovascular MR Imaging at 3.0 T
Lee, V. S., Hecht, E. M., Taouli, B. A., Chen, Q., Prince, K., & Oesingmann, N. (2007) · Radiology · doi:10.1148/radiol.2443060582 · Cited by 90
Clinical e valuation of magnetic resonance imaging in coronary heart disease: The CE-MARC study
Greenwood, J. P., Maredia, N., Radjenovic, A., Brown, J. M., Nixon, J., Farrin, A. J., Dickinson, C. J., Younger, J. F., Ridgway, J. P., Sculpher, M., et al. (2009) · Trials · doi:10.1186/1745-6215-10-62 · Cited by 67 · cited 1×
“A further alternative is to abandon the requirement that each readout pulse has a separate preparation pulse [53].”
Self-citationMichaely, H. J., Nael, K., Schoenberg, S. O., Laub, G. A., Reiser, M. F., Finn, J. P., & Ruehm, S. G. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000192023.96494.af · Cited by 59
Fast, three‐dimensional free‐breathing MR imaging of myocardial infarction: A feasibility study
Saranathan, M., Rochitte, C. E., & Foo, T. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20061 · Cited by 57
Jahnke, C., Nagel, E. C., Gebker, R., Bornstedt, A., Schnackenburg, B., Kozerke, S., Fleck, E., & Paetsch, I. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20877 · Cited by 57
Kellman, P., Chung, Y., Simonetti, O. P., McVeigh, E. R., & Arai, A. E. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20426 · Cited by 56 · cited 1×
“that would improve the contrast between scarred and normal myocardium, as well as scar and blood [84,85].”
Plein, S., Smith, W. H., Ridgway, J. P., Kassner, A., Beacock, D. J., Bloomer, T. N., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1146 · Cited by 52 · cited 2×
“‘Real-Time’ imaging is achieved by selecting a very high turbofactor [24-27], such that the whole image acquisition is completed in a single cardiac phase in a single heart beat (a single-shot acquisition).”
Self-citationMyocardial Viability: Assessment with Three-dimensional MR Imaging in Pigs and Patients
Dewey, M., Laule, M., Taupitz, M., Kaufels, N., Hamm, B., & Kivelitz, D. E. (2006) · Radiology · doi:10.1148/radiol.2393050586 · Cited by 40 · cited 1×
“By collecting the IR prepared signal in a 3D mode, significant savings in imaging time can be achieved [80,81] However, the required readout window is longer compared to 2D and the spatial resolution is significantly reduced too.”
Abbara, S., Migrino, R. Q., Sosnovik, D. E., Leichter, J., Brady, T. J., & Holmvang, G. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.3.1820587 · Cited by 29 · cited 1×
“A fat suppression pulse added to an existing pulse sequence selectively suppresses the MR signal contribution from lipid based tissues [11], thus improving the delineation of non-lipid based structures.”
Cardiovascular Magnetic Resonance
(2010) · Elsevier eBooks · doi:10.1016/c2009-0-48112-1 · Cited by 24
Basic Principles of Cardiovascular Magnetic Resonance
Balaban, R. S., & Peters, D. C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-41561-3.00001-x · Cited by 19
iPAT: Applications for fast and cardiovascular MR imaging
Dietrich, O., Nikolaou, K., Wintersperger, B. J., Flatz, W. H., Nittka, M., Petsch, R., Kiefer, B., & Schoenberg, S. (2002) · Cited by 16
Review of Journal of Cardiovascular Magnetic Resonance 2009
Pennell, D. J., Firmin, D. N., Kilner, P. J., Manning, W. J., Rh, M., Neubauer, S., & Prasad, S. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-15 · Cited by 8
Saleh, R. S., Lohan, D. G., Nael, K., Grover‐McKay, M., & Finn, J. P. (2007) · Applied Radiology · doi:10.37549/ar1563 · Cited by 7
Cardiovascular Magnetic Resonance Contrast Agents
Caravan, P. D. (2010) · Elsevier eBooks · doi:10.1016/b978-0-443-06686-3.00006-0 · Cited by 6
Blood Flow Velocity Assessment
Firmin, D. N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-41561-3.00007-0 · Cited by 4
Cardiovascular Magnetic Resonance Contrast Agents
Gale, E. M., & Caravan, P. D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-41561-3.00004-5 · Cited by 1
Cited by
Coronary microvascular dysfunction: mechanisms and functional assessment
Camici, P. G., d'Amati, G., & Rimoldi, O. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.160 · Cited by 498
T1 Mapping in Characterizing Myocardial Disease: A Comprehensive Review
Puntmann, V. O., Peker, E., Chandrashekhar, Y., & Nagel, E. (2016) · Circulation Research · doi:10.1161/circresaha.116.307974 · Cited by 337
Magnetic Nanomaterials as Contrast Agents for MRI
Caspani, S., Magalhães, R., Araújo, J. P., & Sousa, C. T. (2020) · Materials · doi:10.3390/ma13112586 · Cited by 229
Cardiovascular magnetic resonance artefacts
Ferreira, P. F., Gatehouse, P. D., Mohiaddin, R. H., & Firmin, D. N. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-41 · Cited by 191
“Also, alternatives to these sections are available elsewhere such as the excellent physics articles from Ridgway and Biglands in JCMR 2010 and 2012 [4,5].”
BackgroundRole of Cardiovascular Imaging in the Follow-Up of Patients with Fontan Circulation
Moscatelli, S., Borrelli, N., Sabatino, J., Leo, I., Avesani, M., Montanaro, C., & Di Salvo, G. (2022) · Children · doi:10.3390/children9121875 · Cited by 21
Metadata
- Authors
- Biglands, J. D., Radjenovic, A., & Ridgway, J. P.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 14
- Issue
- 1
- Pages
- 78
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2122678409
- Cited by
- 241
- References
- 84
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.