Global and regional left ventricular myocardial deformation measures by magnetic resonance feature tracking in healthy volunteers: comparison with tagging and relevance of gender
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Feature tracking software offers measurements of myocardial strain, velocities and displacement from cine cardiovascular magnetic resonance (CMR) images. We used it to record deformation parameters in healthy adults and compared values to those obtained by tagging. METHODS: We used TomTec 2D Cardiac Performance Analysis software to derive global, regional and segmental myocardial deformation parameters in 145 healthy volunteers who had steady state free precession (SSFP) cine left ventricular short (basal, mid and apical levels) and long axis views (horizontal long axis, vertical long axis and left ventricular out flow tract) obtained on a 1.5 T Siemens Sonata scanner. 20 subjects also had tagged acquisitions and we compared global and regional deformation values obtained from these with those from Feature Tracking. RESULTS: For globally averaged measurements of strain, only those measured circumferentially in short axis slices showed reasonably good levels of agreement between FT and tagging (limits of agreement -0.06 to 0.04). Longitudinal strain showed wide limits of agreement (-0.16 to 0.03) with evidence of overestimation of strain by FT relative to tagging as the mean of both measures increased. Radial strain was systematically overestimated by FT relative to tagging with very wide limits of agreement extending to as much as 100% of the mean value (-0.01 to 0.23). Reproducibility showed similar relative trends with acceptable global inter-observer variability for circumferential measures (coefficient of variation 4.9%) but poor reproducibility in the radial direction (coefficient of variation 32.3%). Ranges for deformation parameters varied between basal, mid and apical LV levels with higher levels at base compared to apex, and between genders by both FT and tagging. CONCLUSIONS: FT measurements of circumferential but not longitudinally or radially directed global strain showed reasonable agreement with tagging and acceptable inter-observer reproducibility. We record provisional ranges of FT deformation parameters at global, regional and segmental levels. They show evidence of variation with gender and myocardial region in the volunteers studied, but have yet to be compared with tagging measurements at the segmental level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Myocardial Strain Measurement With 2-Dimensional Speckle-Tracking Echocardiography
Marwick, T. H., Leano, R. L., Brown, J., Sun, J.-P., Hoffmann, R., Lysyansky, P., Becker, M., & Thomas, J. D. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.007 · Cited by 529
Edvardsen, T., Gerber, B. L., Garot, J., Bluemke, D. A., Lima, J. A. C., & Smiseth, O. A. (2002) · Circulation · doi:10.1161/01.cir.0000019907.77526.75 · Cited by 523
Moore, C. C., Lugo-Olivieri, C. H., McVeigh, E. R., & Zerhouni, E. A. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe17453 · Cited by 421
Hor, K. N., Gottliebson, W. M., Carson, C., Wash, E., Cnota, J., Fleck, R., Wansapura, J., Klimeczek, P., Al-Khalidi, H. R., Chung, E. S., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.006 · Cited by 379
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Popović, Z. B., Kwon, D. H., Mishra, M., Buakhamsri, A., Greenberg, N. L., Thamilarasan, M., Flamm, S. D., Thomas, J. D., Lever, H. M., & Desai, M. Y. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.011 · Cited by 252
Saito, K., Okura, H., Watanabe, N., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.05.021 · Cited by 247
Ng, A. C. T., Delgado, V., Bertini, M., Antoni, M. L., van Bommel, R. J., van Rijnsoever, E. P. M., van der Kley, F., Ewe, S. H., Witkowski, T., Auger, D., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr084 · Cited by 224
Cited by
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Kawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Myocardial strain imaging: review of general principles, validation, and sources of discrepancies
Amzulescu, M. S., De Craene, M., Langet, H., Pasquet, A., Vancraeynest, D., Pouleur, A. C., Vanoverschelde, J. L., & Gerber, B. L. (2019) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jez041 · Cited by 472
Tissue Tracking Technology for Assessing Cardiac Mechanics
Claus, P., Omar, A. M. S., Pedrizzetti, G., Sengupta, P. P., & Nagel, E. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.11.001 · Cited by 439
Strain imaging using cardiac magnetic resonance
Scatteia, A., Baritussio, A., & Bucciarelli-Ducci, C. (2017) · Heart Failure Reviews · doi:10.1007/s10741-017-9621-8 · Cited by 366
Right Ventricular Systolic Dysfunction in Young Adults Born Preterm
Lewandowski, A. J., Bradlow, W. M., Augustine, D., Davis, E. F., Francis, J., Singhal, A., Lucas, A., Neubauer, S., McCormick, K., & Leeson, P. (2013) · Circulation · doi:10.1161/circulationaha.113.002583 · Cited by 264
Self-citationBuss, S. J., Breuninger, K., Lehrke, S., Voss, A., Galuschky, C., Lossnitzer, D., Andre, F., Ehlermann, P., Franke, J., Taeger, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jeu181 · Cited by 262
Galderisi, M., Cardim, N., D'Andrea, A., Bruder, O., Cosyns, B., Davin, L., Donal, E., Edvardsen, T., Freitas, A., Habib, G., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu323 · Cited by 258
Self-citationMyocardial strain measurement with feature-tracking cardiovascular magnetic resonance: normal values
Taylor, R. J., Moody, W. E., Umar, F., Edwards, N. C., Taylor, T. J., Stegemann, B., Townend, J. N., Hor, K. N., Steeds, R. P., Mazur, W., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev006 · Cited by 251
Eitel, I., Stiermaier, T., Lange, T., Rommel, K.-P., Koschalka, A., Kowallick, J. T., Lotz, J., Kutty, S., Gutberlet, M., Hasenfuß, G., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.11.034 · Cited by 217
“Similar to tracking “speckles” with speckle-tracking echocardiography, the FT software follows “features” that represent distinctive patterns related to the endocardial or epicardial contour to quantify myocardial strain frame to frame over the whole heart cycle (11,33).”
Andre, F., Steen, H., Matheis, P., Westkott, M., Breuninger, K., Sander, Y., Kammerer, R., Galuschky, C., Giannitsis, E., Korosoglou, G., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0123-3 · Cited by 217
“Reference values from prior studies were derived from images acquired on Siemens or GE scanners [10,11] whereas our SSFP datasets were acquired on a Philips system.”
BackgroundMethodOnishi, T., Saha, S. K., Delgado-Montero, A., Ludwig, D. R., Onishi, T., Schelbert, E. B., Schwartzman, D., & Gorcsan, J. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.018 · Cited by 173
Metadata
- Authors
- Augustine, D., Lewandowski, A. J., Lazdam, M., Rai, A., Francis, J., Myerson, S., Noble, A., Becher, H., Neubauer, S., Petersen, S. E., & Leeson, P.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 15
- Issue
- 1
- Pages
- 8
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2169460103
- Cited by
- 285
- References
- 21
- FWCI
- 14.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.