Cardiovascular magnetic resonance in pregnancy: Insights from the cardiac hemodynamic imaging and remodeling in pregnancy (CHIRP) study
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cardiovascular disease in pregnancy is the leading cause of maternal mortality in North America. Although transthoracic echocardiography (TTE) is the most widely used imaging modality for the assessment of cardiovascular function during pregnancy, little is known on the role of cardiovascular magnetic resonance (CMR). The objective of the Cardiac Hemodynamic Imaging and Remodeling in Pregnancy (CHIRP) study was to compare TTE and CMR in the non-invasive assessment of maternal cardiac remodeling during the peripartum period. METHODS: Between 2010-2012, healthy pregnant women aged 18 to 35 years were prospectively enrolled. All women underwent TTE and CMR during the third trimester and at least 3 months postpartum (surrogate for non-pregnant state). RESULTS: The study population included a total of 34 women (mean age 29 ± 3 years). During the third trimester, TTE and CMR demonstrated an increase in left ventricular end-diastolic volume from 95 ± 11 mL to 115 ± 14 mL and 98 ± 6 mL to 125 ± 5 mL, respectively (p<0.05). By TTE and CMR, there was also an increase in left ventricular (LV) mass during pregnancy from 111 ± 10 g to 163 ± 11 g and 121 ± 5 g to 179 ± 5 g, respectively (p<0.05). Although there was good correlation between both imaging modalities for LV mass, stroke volume, and cardiac output, the values were consistently underestimated by TTE. CONCLUSION: This CMR study provides reference values for cardiac indices during normal pregnancy and the postpartum state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Nagueh, S. F., Middleton, K. J., Kopelen, H. A., Zoghbi, W. A., & Quiñones, M. A. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00344-6 · Cited by 3,029 · cited 2×
“While normal standards of maternal cardiac structure and function are well established for TTE, based on studies conducted since the 1960’s [10-15,17,18,20,41-47] this is the first study to longitudinally assess normal changes in”
BackgroundMethodBellenger, N. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2011 · Cited by 1,040 · cited 3×
“To the best of our knowledge, this is the first study to longitudinally assess CO and SV using CMR in pregnancy, which is known to have improved accuracy and reproducibility for assessment of LV volumes [24].”
BackgroundSerial study of factors influencing changes in cardiac output during human pregnancy
Robson, S. C., Hunter, S., Boys, R. J., & Dunlop, W. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.4.h1060 · Cited by 839 · cited 4×
“The combination of decreased left ventricular (LV) afterload, increased preload, and a concomitant increase in resting heart rate leads to an increase in cardiac output (CO) over the same period [4,9-16].”
BackgroundMethodInfluentialACR Guidance Document for Safe MR Practices: 2007
Kanal, E., Barkovich, A. J., Bell, C., Borgstede, J. P., Bradley, W. G., Froelich, J. W., Gilk, T., Gimbel, J. R., Gosbee, J., Kuhni-Kaminski, E., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1616 · Cited by 787
Pregnancy-Related Mortality in the United States, 1998 to 2005
Berg, C. J., Callaghan, W. M., Syverson, C., & Henderson, Z. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181fdfb11 · Cited by 688
Left Ventricular Volumes and Ejection Fraction by Echocardiography
POMBO, J. F., TROY, B. L., & RUSSELL, R. O. (1971) · Circulation · doi:10.1161/01.cir.43.4.480 · Cited by 647 · cited 13×
“Fok WY, Chan LY, Wong JT, Yu CM, Lau TK. Left ventricular diastolic function during normal pregnancy: assessment by spectral tissue Doppler imaging.”
MethodInfluentialMaceira, A. M., Prasad, S. K., Khan, M., & Pennell, D. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl336 · Cited by 561 · cited 2×
“Whereas quantitative assessment of the RV using TTE is difficult due to its complex geometry, CMR serves as the gold standard for non-invasive assessment of this chamber due to its higher spatial resolution and low intra- and inter-observer variability [42].”
BackgroundMethodTemporal relationships between hormonal and hemodynamic changes in early human pregnancy
Chapman, A. B., Abraham, W. T., Zamudio, S., Coffin, C., Merouani, A., Young, D., Johnson, A., Osorio, F., Goldberg, C., Moore, L. G., et al. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00217.x · Cited by 539 · cited 1×
“resistance (SVR), resulting from peripheral vasodilation and a low-resistance utero-placental circulation [4-6].”
BackgroundCatheterization of the Right Auricle in Man
Cournand, A., & Ranges, H. A. (1941) · Experimental Biology and Medicine · doi:10.3181/00379727-46-12029 · Cited by 450 · cited 1×
“These methods range from the invasive dye-dilution technique in 1915 [18], the Cournand cardiac catheterization technique with the direct Fick method in the late 1940s [19,20], M-mode echocardiography beginning in the 1960s and refined with pulsed-wave Doppler [21], and more recently, Swan-Ganz pulmonary artery cathet…”
Method
Cited by
Lyon, A. R., López-Fernández, T., Couch, L. S., Asteggiano, R., Aznar, M. C., Bergler-Klein, J., Boriani, G., Cardinale, D., Cordoba, R., Cosyns, B., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac244 · Cited by 3,076
Cardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
Cardiovascular Physiology of Pregnancy
Sanghavi, M., & Rutherford, J. D. (2014) · Circulation · doi:10.1161/circulationaha.114.009029 · Cited by 1,188
Dennis, A., Wamil, M., Alberts, J., Oben, J., Cuthbertson, D. J., Wootton, D., Crooks, M., Gabbay, M., Brady, M., Hishmeh, L., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-048391 · Cited by 560
Lyon, A. R., López-Fernández, T., Couch, L. S., Asteggiano, R., Aznar, M. C., Bergler-Klein, J., Boriani, G., Cardinale, D., Cordoba, R., Cosyns, B., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeac106 · Cited by 507
ACOG Practice Bulletin No. 212: Pregnancy and Heart Disease
(2019) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003243 · Cited by 447
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Metadata
- Authors
- Ducas, R. A., Elliott, J. E., Melnyk, S. F., Premecz, S., daSilva, M., Cleverley, K., Wtorek, P., Mackenzie, G. S., Helewa, M. E., & Jassal, D. S.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 16
- Issue
- 1
- Pages
- 1
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2042923739
- Cited by
- 182
- References
- 35
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.