Routine resite of peripheral intravenous devices every 3 days did not reduce complications compared with clinically indicated resite: a randomised controlled trial
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Peripheral intravenous device (IVD) complications were traditionally thought to be reduced by limiting dwell time. Current recommendations are to resite IVDs by 96 hours with the exception of children and patients with poor veins. Recent evidence suggests routine resite is unnecessary, at least if devices are inserted by a specialised IV team. The aim of this study was to compare the impact of peripheral IVD 'routine resite' with 'removal on clinical indication' on IVD complications in a general hospital without an IV team. METHODS: A randomised, controlled trial was conducted in a regional teaching hospital. After ethics approval, 362 patients (603 IVDs) were randomised to have IVDs replaced on clinical indication (185 patients) or routine change every 3 days (177 patients). IVDs were inserted and managed by the general hospital medical and nursing staff; there was no IV team. The primary endpoint was a composite of IVD complications: phlebitis, infiltration, occlusion, accidental removal, local infection, and device-related bloodstream infection. RESULTS: IVD complication rates were 68 per 1,000 IVD days (clinically indicated) and 66 per 1,000 IVD days (routine replacement) (P = 0.86; HR 1.03; 95% CI, 0.74-1.43). Time to first complication per patient did not differ between groups (KM with log rank, P = 0.53). There were no local infections or IVD-related bloodstream infections in either group. IV therapy duration did not differ between groups (P = 0.22), but more (P = 0.004) IVDs were placed per patient in the routine replacement (mean, 1.8) than the clinical indication group (mean, 1.5), with significantly higher hospital costs per patient (P < 0.001). CONCLUSIONS: Resite on clinical indication would allow one in two patients to have a single cannula per course of IV treatment, as opposed to one in five patients managed with routine resite; overall complication rates appear similar. Clinically indicated resite would achieve savings in equipment, staff time and patient discomfort. There is growing evidence to support the extended use of peripheral IVDs with removal only on clinical indication. REGISTRATION NUMBER: Australian New Zealand Clinical Trials Registry (ANZCTR) Number ACTRN12608000421336.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549 · cited 1×
“Serious adverse outcomes are fortunately rare, with IVD-related bloodstream infection reported in a recent meta-analysis of 110 studies to occur in 0.1% of devices and 0.5 per 1,000 device days [ 2 ].”
BackgroundInfluentialGuidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
On the regression analysis of multivariate failure time data
PRENTICE, R. L., WILLIAMS, B. J., & PETERSON, A. V. (1981) · Biometrika · doi:10.1093/biomet/68.2.373 · Cited by 1,333 · cited 1×
“, same patient multiple failure-time data) within the Cox model, we also used the Prentice-Williams-Peterson conditional risk-set method [26].”
MethodGuidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
How should cost data in pragmatic randomised trials be analysed?
Thompson, S. G. (2000) · BMJ · doi:10.1136/bmj.320.7243.1197 · Cited by 772 · cited 1×
“Cost differences were calculated using arithmetic means and the t-test [27].”
MethodMaki, D. G., & Ringer, M. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-10-845 · Cited by 497
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Clinically-indicated replacement versus routine replacement of peripheral venous catheters
Webster, J., Osborne, S., Rickard, C. M., & New, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007798.pub3 · Cited by 313
Self-citationIs Routine Replacement of Peripheral Intravenous Catheters Necessary?
Bregenzer, T., Conen, D., Sakmann, P., & Widmer, A. F. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.2.151 · Cited by 201 · cited 1×
“Welldesigned cohort studies with modern catheter materials suggest that the daily risk of phlebitis is relatively stable after the first 24 or 48 hours [3,21,28-31].”
BackgroundWebster, J., Clarke, S., Paterson, D., Hutton, A., Dyk, S. V., Gale, C., & Hopkins, T. (2008) · BMJ · doi:10.1136/bmj.a339 · Cited by 190
Cited by
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Accepted but Unacceptable: Peripheral IV Catheter Failure
Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E. (2015) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000100 · Cited by 445
Rickard, C. M., Webster, J., Wallis, M. C., Marsh, N., McGrail, M. R., French, V., Foster, L., Gallagher, P., Gowardman, J. R., Zhang, L., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61082-4 · Cited by 428
Self-citationClinically-indicated replacement versus routine replacement of peripheral venous catheters
Webster, J., Osborne, S., Rickard, C. M., & New, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007798.pub3 · Cited by 313
Self-citationShort-term Peripheral Venous Catheter–Related Bloodstream Infections: A Systematic Review
Mermel, L. A. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/cix562 · Cited by 253
Short Peripheral Intravenous Catheters and Infections
Hadaway, L. (2012) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e31825af099 · Cited by 211
Marsh, N., Webster, J., Ullman, A. J., Mihala, G., Cooke, M., Chopra, V., & Rickard, C. M. (2020) · Journal of Advanced Nursing · doi:10.1111/jan.14565 · Cited by 186
“Additional information was provided from authors for nine studies (Bugden et al., 2016; Forni et al., 2012; Keogh et al., 2016; Marsh, et al., 2018; Rickard et al., 2010, 2012; Van Donk, 2009; Webster et al., 2007, 2008).”
BackgroundInfluentialSelf-citationMiliani, K., Taravella, R., Thillard, D., Chauvin, V., Martin, E., Edouard, S., Astagneau, P., & on behalf of the CATHEVAL Study Group (2017) · PLOS ONE · doi:10.1371/journal.pone.0168637 · Cited by 175
“Similarly, incidence rates of infiltration reach up to 30% of inserted PVCs [4,9].”
Influential
Metadata
- Authors
- Rickard, C. M., McCann, D., Munnings, J., & McGrail, M. R.
- Venue
- BMC Medicine
- Published
- 2010-09-10
- Volume
- 8
- Issue
- 1
- Pages
- 53-53
- ISSN
- 1741-7015 (ISSN-L)
- OpenAlex
- W2119660112
- Cited by
- 160
- References
- 25
- FWCI
- 9.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.