Cosinor-based rhythmometry
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
A brief overview is provided of cosinor-based techniques for the analysis of time series in chronobiology. Conceived as a regression problem, the method is applicable to non-equidistant data, a major advantage. Another dividend is the feasibility of deriving confidence intervals for parameters of rhythmic components of known periods, readily drawn from the least squares procedure, stressing the importance of prior (external) information. Originally developed for the analysis of short and sparse data series, the extended cosinor has been further developed for the analysis of long time series, focusing both on rhythm detection and parameter estimation. Attention is given to the assumptions underlying the use of the cosinor and ways to determine whether they are satisfied. In particular, ways of dealing with non-stationary data are presented. Examples illustrate the use of the different cosinor-based methods, extending their application from the study of circadian rhythms to the mapping of broad time structures (chronomes).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Time Series Analysis: Forecasting and Control
Geurts, M., Box, G. E. P., & Jenkins, G. M. (1977) · Journal of Marketing Research · doi:10.2307/3150485 · Cited by 19,186
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
Practical Nonparametric Statistics
Groggel, D. J. (2000) · Technometrics · doi:10.1080/00401706.2000.10486067 · Cited by 11,041
Peto, R., Pike, M. C., Armitage, P., Breslow, N. E., Cox, D. R., Howard, S. V., Mantel, N., McPherson, K., Peto, J., & Smith, P. G. (1977) · British Journal of Cancer · doi:10.1038/bjc.1977.1 · Cited by 8,285
Scargle, J. D. (1982) · The Astrophysical Journal · doi:10.1086/160554 · Cited by 7,376
Time Series Analysis Forecasting and Control.
Bartholomew, D. J., Box, G. E. P., & Jenkins, G. M. (1971) · Operational Research Quarterly (1970-1977) · doi:10.2307/3008255 · Cited by 6,716
The wavelet transform, time-frequency localization and signal analysis
Daubechies, I. (1990) · IEEE Transactions on Information Theory · doi:10.1109/18.57199 · Cited by 6,483 · cited 1×
“When data are equidistant or rendered equidistant by averaging and filling data gaps by interpolation, wavelets can be performed [85].”
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
Cited by
Detecting Rhythms in Time Series with RAIN
Thaben, P. F., & Westermark, P. O. (2014) · Journal of Biological Rhythms · doi:10.1177/0748730414553029 · Cited by 706
Light-entrained and brain-tuned circadian circuits regulate ILC3s and gut homeostasis
Godinho-Silva, C., Domingues, R. G., Rendas, M., Raposo, B., Ribeiro, H., da Silva, J. A., Vieira, A., Costa, R. M., Barbosa-Morais, N. L., Carvalho, T., et al. (2019) · Nature · doi:10.1038/s41586-019-1579-3 · Cited by 219
Data Integration Challenges for Machine Learning in Precision Medicine
Martínez-García, M., & Hernández-Lemus, E. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2021.784455 · Cited by 185
Rykov, Y., Thach, T.-Q., Bojic, I., Christopoulos, G., & Car, J. (2021) · JMIR mHealth and uHealth · doi:10.2196/24872 · Cited by 151
Kervezee, L., Cuesta, M., Cermakian, N., & Boivin, D. B. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1720719115 · Cited by 136
“Amplitude and phase (time of peak) were calculated from the cosinor coefficients b and c (37).”
MethodOrigins of human disease: the chrono-epigenetic perspective
Oh, E. S., & Petronis, A. (2021) · Nature Reviews Genetics · doi:10.1038/s41576-021-00348-6 · Cited by 108
24-h activity rhythm and sleep in depressed outpatients
Hori, H., Koga, N., Hidese, S., Nagashima, A., Kim, Y., Higuchi, T., & Kunugi, H. (2016) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2016.02.022 · Cited by 78
Bishehsari, F., Engen, P. A., Voigt, R. M., Swanson, G., Shaikh, M., Wilber, S., Naqib, A., Green, S. J., Shetuni, B., Forsyth, C. B., et al. (2020) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2019.10.011 · Cited by 76
“For Per2::luc analysis, given the established rhythmicity of Per2 in the mouse tissue of approximate 24-hour periodicity,(73) a single cosinor method was used to analyze the data over time as described.(74) The equation for the cosinor fit is as follows: Y(t) 1⁄4 M þ Acos(2pt/s þ f), where M is the mesor (midline stat…”
MethodSaner, N. J., Lee, M. J.-C., Kuang, J., Pitchford, N. W., Roach, G. D., Garnham, A., Genders, A. J., Stokes, T., Schroder, E. A., Huo, Z., et al. (2021) · Molecular Metabolism · doi:10.1016/j.molmet.2020.101110 · Cited by 68
Circadian disruption and cancer- and treatment-related symptoms
Amidi, A., & Wu, L. M. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1009064 · Cited by 59
Banek, C. T., Gauthier, M. M., Baumann, D. C., Van Helden, D., Asirvatham-Jeyaraj, N., Panoskaltsis-Mortari, A., Fink, G. D., & Osborn, J. W. (2018) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00416.2017 · Cited by 58
“To assess diurnal rhythm of mean arterial pressure before and after treatment, hourly averages of a 24-h cycle (protocol days 1 and 14) were analyzed using a single-component cosinor regression (9).”
MethodDiurnal rhythms of wrist temperature are associated with future disease risk in the UK Biobank
Brooks, T. G., Lahens, N. F., Grant, G. R., Sheline, Y. I., FitzGerald, G. A., & Skarke, C. (2023) · Nature Communications · doi:10.1038/s41467-023-40977-5 · Cited by 57
“Diurnal rhythms were computed via cosinor fi ts 66 of the wrist temperatures (Supplementary Fig.”
Debono, M., Mallappa, A., Gounden, V., Nella, A. A., Harrison, R. F., Crutchfield, C. A., Backlund, P. S., Soldin, S. J., Ross, R. J., & Merke, D. P. (2015) · European Journal of Endocrinology · doi:10.1530/eje-15-0064 · Cited by 53
Engel, S., Laufer, S., Miller, R., Niemeyer, H., Knaevelsrud, C., & Schumacher, S. (2019) · Frontiers in Neuroendocrinology · doi:10.1016/j.yfrne.2019.100775 · Cited by 50
Winer, J. R., Lok, R., Weed, L., He, Z., Poston, K. L., Mormino, E. C., & Zeitzer, J. M. (2024) · Alzheimer's Research & Therapy · doi:10.1186/s13195-024-01411-0 · Cited by 44
“Cosinor analyses (fitting a cosine wave to the data) were performed using the cosinor2 package in R [19] and resulted in two metrics of interest: (1) mesor (rhythm-adjusted mean activity) and (2) amplitude (half the difference between peak and nadir of fitted cosine wave).”
MethodHasenmajer, V., Sbardella, E., Sciarra, F., Simeoli, C., Pivonello, C., Ceccato, F., Pofi, R., Minnetti, M., Rizzo, F., Ferrari, D., et al. (2024) · eBioMedicine · doi:10.1016/j.ebiom.2024.105462 · Cited by 29
“29 We employed a mixed effects cosinor model to analyse longitudinal periodic data using the R package “ cosinoRmixedeffects ” , where estimation and hypothesis testing for the non-linear circadian parameters are conducted through bootstrapping.”
Jang, T.-W., Kim, H., Kang, S.-H., Choo, S.-H., Lee, I.-S., & Choi, K.-H. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14101109 · Cited by 21
Metadata
- Authors
- Cornelissen, G.
- Venue
- Theoretical Biology and Medical Modelling
- Published
- 2014-04-11
- Volume
- 11
- Issue
- 1
- Pages
- 16-16
- ISSN
- 1742-4682 (ISSN-L)
- OpenAlex
- W2098342740
- Cited by
- 811
- References
- 71
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.