The DOI matches its Crossref record.
Wearable Conductive Fiber Sensors for Multi-Axis Human Joint Angle Measurements
Open accessAbstract
Background: The practice of continuous, long-term monitoring of human joint motion is one that finds many applications, especially in the medical and rehabilitation fields. There is a lack of acceptable devices available to perform such measurements in the field in a reliable and non-intrusive way over a long period of time. The purpose of this study was therefore to develop such a wearable joint monitoring sensor capable of continuous, day-to-day monitoring. Methods: A novel technique of incorporating conductive fibers into flexible, skin-tight fabrics surrounding a joint is developed. Resistance changes across these conductive fibers are measured, and directly related to specific single or multi-axis joint angles through the use of a non-linear predictor after an initial, one-time calibration. Because these sensors are intended for multiple uses, an automated registration algorithm has been devised using a sensitivity template matched to an array of sensors spanning the joints of interest. In this way, a sensor array can be taken off and put back on an individual for multiple uses, with the sensors automatically calibrating themselves each time. Results: The wearable sensors designed are comfortable, and acceptable for long-term wear in everyday settings. Results have shown the feasibility of this type of sensor, with accurate measurements of joint motion for both a single-axis knee joint and a double axis hip joint when compared to a standard goniometer used to measure joint angles. Self-registration of the sensors was found to be possible with only a few simple motions by the patient. Conclusion: After preliminary experiments involving a pants sensing garment for lower body monitoring, it has been seen that this methodology is effective for monitoring joint motion of the hip and knee. This design therefore produces a robust, comfortable, truly wearable joint monitoring device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrastretchable Fibers with Metallic Conductivity Using a Liquid Metal Alloy Core
Zhu, S., So, J., Mays, R., Desai, S., Barnes, W. R., Pourdeyhimi, B., & Dickey, M. D. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201202405 · Cited by 638
Seyedin, S., Zhang, P., Naebe, M., Qin, S., Chen, J., Wang, X., & Razal, J. M. (2019) · Materials Horizons · doi:10.1039/c8mh01062e · Cited by 421
Knitted Strain Sensor Textiles of Highly Conductive All-Polymeric Fibers
Seyedin, S., Razal, J. M., Innis, P. C., Jeiranikhameneh, A., Beirne, S., & Wallace, G. G. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04892 · Cited by 331
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Sensor Evaluation for Wearable Strain Gauges in Neurological Rehabilitation
Giorgino, T., Tormene, P., Lorussi, F., De Rossi, D., & Quaglini, S. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2019584 · Cited by 100
Metadata
- Authors
- Gibbs, P. T., & Asada, H.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2005-03-02
- Volume
- 2
- Issue
- 1
- ISSN
- 1743-0003
- OpenAlex
- W1855416518
- Cited by
- 169
- References
- 0
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Conductive Fiber Sensors for Multi-Axis Human Joint Angle Measurements. https://app.cochat.ai/papers/10.1186/1743-0003-2-7
- The paper
- Gibbs, P. T., & Asada, H. (2005). Wearable Conductive Fiber Sensors for Multi-Axis Human Joint Angle Measurements. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-2-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.