The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Gait rehabilitation machines based on programmable footplates
Open accessAbstract
BACKGROUND: Gait restoration is an integral part of rehabilitation of brain lesioned patients. Modern concepts favour a task-specific repetitive approach, i.e. who wants to regain walking has to walk, while tone-inhibiting and gait preparatory manoeuvres had dominated therapy before. Following the first mobilization out of the bed, the wheelchair-bound patient should have the possibility to practise complex gait cycles as soon as possible. Steps in this direction were treadmill training with partial body weight support and most recently gait machines enabling the repetitive training of even surface gait and even of stair climbing. RESULTS: With treadmill training harness-secured and partially relieved wheelchair-mobilised patients could practise up to 1000 steps per session for the first time. Controlled trials in stroke and SCI patients, however, failed to show a superior result when compared to walking exercise on the floor. Most likely explanation was the effort for the therapists, e.g. manually setting the paretic limbs during the swing phase resulting in a too little gait intensity. The next steps were gait machines, either consisting of a powered exoskeleton and a treadmill (Lokomat, AutoAmbulator) or an electromechanical solution with the harness secured patient placed on movable foot plates (Gait Trainer GT I). For the latter, a large multi-centre trial with 155 non-ambulatory stroke patients (DEGAS) revealed a superior gait ability and competence in basic activities of living in the experimental group. The HapticWalker continued the end effector concept of movable foot plates, now fully programmable and equipped with 6 DOF force sensors. This device for the first time enables training of arbitrary walking situations, hence not only the simulation of floor walking but also for example of stair climbing and perturbations. CONCLUSION: Locomotor therapy is a fascinating new tool in rehabilitation, which is in line with modern principles of motor relearning promoting a task-specific repetitive approach. Sophisticated technical developments and positive randomized controlled trials form the basis of a growing acceptance worldwide to the benefits or our patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1965) · PubMed · Cited by 14,925
Functional evaluation : Barthel index
Mahonery, F. I. (1965) · Medical Entomology and Zoology · Cited by 12,762
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
The cochrane database of systematic reviews
Geddes, J. (1996) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(96)90063-x · Cited by 5,989
The Cochrane Database of Systematic Reviews
Handoll, H. H. (2004) · The British Journal of Hand Therapy · doi:10.1177/175899830400900201 · Cited by 1,513
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Mahoney, F. I., & Barthel, D. W. (2013) · PsycTESTS Dataset · doi:10.1037/t02366-000 · Cited by 887
(2006) · Springer eBooks · doi:10.1007/0-387-28287-4 · Cited by 717
Mobility after stroke: Reliability of measures of impairment and disability
Collen, F. M., Wade, D. T., & Bradshaw, C. M. (1990) · International Disability Studies · doi:10.3109/03790799009166594 · Cited by 669
Cited by
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Assistive mobility devices focusing on Smart Walkers: Classification and review
Martins, M. M., Santos, C. P., Frizera-Neto, A., & Ceres, R. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2011.11.015 · Cited by 260
Borggraefe, I., Schaefer, J. S., Klaiber, M., Dabrowski, E., Ammann-Reiffer, C., Knecht, B., Berweck, S., Heinen, F., & Meyer-Heim, A. (2010) · European Journal of Paediatric Neurology · doi:10.1016/j.ejpn.2010.01.002 · Cited by 169
Cao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
Metadata
- Authors
- Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., & Krüger, J.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2007-02-09
- Volume
- 4
- Issue
- 1
- Pages
- 2-2
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2150151850
- Cited by
- 256
- References
- 34
- FWCI
- 10.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gait rehabilitation machines based on programmable footplates. https://app.cochat.ai/papers/10.1186/1743-0003-4-2
- The paper
- Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., & Krüger, J. (2007). Gait rehabilitation machines based on programmable footplates. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-4-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.