The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
High-density surface EMG maps from upper-arm and forearm muscles
Open accessAbstract
Background: sEMG signal has been widely used in different applications in kinesiology and rehabilitation as well as in the control of human-machine interfaces. In general, the signals are recorded with bipolar electrodes located in different muscles. However, such configuration may disregard some aspects of the spatial distribution of the potentials like location of innervation zones and the manifestation of inhomogineties in the control of the muscular fibers. On the other hand, the spatial distribution of motor unit action potentials has recently been assessed with activation maps obtained from High Density EMG signals (HD-EMG), these lasts recorded with arrays of closely spaced electrodes. The main objective of this work is to analyze patterns in the activation maps, associating them with four movement directions at the elbow joint and with different strengths of those tasks. Although the activation pattern can be assessed with bipolar electrodes, HD-EMG maps could enable the extraction of features that depend on the spatial distribution of the potentials and on the load-sharing between muscles, in order to have a better differentiation between tasks and effort levels. Methods: An experimental protocol consisting of isometric contractions at three levels of effort during flexion, extension, supination and pronation at the elbow joint was designed and HD-EMG signals were recorded with 2D electrode arrays on different upper-limb muscles. Techniques for the identification and interpolation of artifacts are explained, as well as a method for the segmentation of the activation areas. In addition, variables related to the intensity and spatial distribution of the maps were obtained, as well as variables associated to signal power of traditional single bipolar recordings. Finally, statistical tests were applied in order to assess differences between information extracted from single bipolar signals or from HD-EMG maps and to analyze differences due to type of task and effort level. Results: Significant differences were observed between EMG signal power obtained from single bipolar configuration and HD-EMG and better results regarding the identification of tasks and effort levels were obtained with the latter. Additionally, average maps for a population of 12 subjects were obtained and differences in the co-activation pattern of muscles were found not only from variables related to the intensity of the maps but also to their spatial distribution. Conclusions: Intensity and spatial distribution of HD-EMG maps could be useful in applications where the identification of movement intention and its strength is needed, for example in robotic-aided therapies or for devices like powered- prostheses or orthoses. Finally, additional data transformations or other features are necessary in order to improve the performance of tasks identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring nominal scale agreement among many raters.
Fleiss, J. L. (1971) · Psychological Bulletin · doi:10.1037/h0031619 · Cited by 8,733
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Algorithmic Stability and Sanity-Check Bounds for Leave-One-Out Cross-Validation
Kearns, M., & Ron, D. (1999) · Neural Computation · doi:10.1162/089976699300016304 · Cited by 407
Cited by
Gesture recognition by instantaneous surface EMG images
Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., & Li, J. (2016) · Scientific Reports · doi:10.1038/srep36571 · Cited by 595
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Rojas-Martínez, M., Mañanas, M. A., & Alonso, J. F.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2012-12
- Volume
- 9
- Issue
- 1
- Pages
- 85-85
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2014734344
- Cited by
- 181
- References
- 3
- FWCI
- 2.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-density surface EMG maps from upper-arm and forearm muscles. https://app.cochat.ai/papers/10.1186/1743-0003-9-85
- The paper
- Rojas-Martínez, M., Mañanas, M. A., & Alonso, J. F. (2012). High-density surface EMG maps from upper-arm and forearm muscles. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-9-85
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.