The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Comparative inhalation toxicity of multi-wall carbon nanotubes, graphene, graphite nanoplatelets and low surface carbon black
Open accessAbstract
Background: Carbon nanotubes, graphene, graphite nanoplatelets and carbon black are seemingly chemically identical carbon-based nano-materials with broad technological applications. Carbon nanotubes and carbon black possess different inhalation toxicities, whereas little is known about graphene and graphite nanoplatelets. Methods: In order to compare the inhalation toxicity of the mentioned carbon-based nanomaterials, male Wistar rats were exposed head-nose to atmospheres of the respective materials for 6 hours per day on 5 consecutive days. Target concentrations were 0.1, 0.5, or 2.5 mg/m 3 for multi-wall carbon nanotubes and 0.5, 2.5, or 10 mg/m 3 for graphene, graphite nanoplatelets and low-surface carbon black. Toxicity was determined after end of exposure and after three-week recovery using broncho-alveolar lavage fluid and microscopic examinations of the entire respiratory tract. Results: No adverse effects were observed after inhalation exposure to 10 mg/m 3 graphite nanoplatelets or relatively low specific surface area carbon black. Increases of lavage markers indicative for inflammatory processes started at exposure concentration of 0.5 mg/m 3 for multi-wall carbon nanotubes and 10 mg/m 3 for graphene. Consistent with the changes in lavage fluid, microgranulomas were observed at 2.5 mg/m 3 multi-wall carbon nanotubes and 10 mg/m 3 graphene. In order to evaluate volumetric loading of the lung as the key parameter driving the toxicity, deposited particle volume was calculated, taking into account different methods to determine the agglomerate density. However, the calculated volumetric load did not correlate to the toxicity, nor did the particle surface burden of the lung. Conclusions: The inhalation toxicity of the investigated carbon-based materials is likely to be a complex interaction of several parameters. Until the properties which govern the toxicity are identified, testing by short-term inhalation is the best option to identify hazardous properties in order to avoid unsafe applications or select safer alternatives for a given application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poland, C. A., Duffin, R., Kinloch, I., Maynard, A., Wallace, W. A. H., Seaton, A., Stone, V., Brown, S., MacNee, W., & Donaldson, K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.111 · Cited by 2,645
Respiratory toxicity of multi-wall carbon nanotubes
Muller, J., Huaux, F., Moreau, N., Misson, P., Heilier, J.-F., Delos, M., Arras, M., Fonseca, A., Nagy, J. B., & Lison, D. (2005) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2005.01.008 · Cited by 1,123
Muller, J., Huaux, F., Fonseca, A., Nagy, J. B., Moreau, N., Delos, M., Raymundo-Piñero, E., Béguin, F., Kirsch-Volders, M., Fenoglio, I., et al. (2008) · Chemical Research in Toxicology · doi:10.1021/tx800101p · Cited by 261
Pauluhn, J. (2011) · Toxicology · doi:10.1016/j.tox.2010.10.009 · Cited by 124
Cited by
Müller, K., Bugnicourt, E., Latorre, M., Jorda, M., Echegoyen Sanz, Y., Lagaron, J., Miesbauer, O., Bianchin, A., Hankin, S., Bölz, U., et al. (2017) · Nanomaterials · doi:10.3390/nano7040074 · Cited by 746
Toxicity of metal and metal oxide nanoparticles: a review
Sengul, A. B., & Asmatulu, E. (2020) · Environmental Chemistry Letters · doi:10.1007/s10311-020-01033-6 · Cited by 681
Assessment of the toxic potential of graphene family nanomaterials
Guo, X., & Mei, N. (2014) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2014.01.009 · Cited by 421
Biomedical Uses for 2D Materials Beyond Graphene: Current Advances and Challenges Ahead
Kurapati, R., Kostarelos, K., Prato, M., & Bianco, A. (2016) · Advanced Materials · doi:10.1002/adma.201506306 · Cited by 417
Physicochemical characteristics of nanomaterials that affect pulmonary inflammation
Braakhuis, H. M., Park, M. V., Gosens, I., De Jong, W. H., & Cassee, F. R. (2014) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-11-18 · Cited by 358
Metadata
- Authors
- Ma-Hock, L., Strauss, V., Treumann, S., Küttler, K., Wohlleben, W., Hofmann, T., Gröters, S., Wiench, K., van Ravenzwaay, B., & Landsiedel, R.
- Venue
- Particle and Fibre Toxicology
- Published
- 2013-06-17
- Volume
- 10
- Issue
- 1
- Pages
- 23-23
- ISSN
- 1743-8977 (ISSN-L)
- OpenAlex
- W2131621090
- Cited by
- 202
- References
- 4
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative inhalation toxicity of multi-wall carbon nanotubes, graphene, graphite nanoplatelets and low surface carbon black. https://app.cochat.ai/papers/10.1186/1743-8977-10-23
- The paper
- Ma-Hock, L., Strauss, V., Treumann, S., Küttler, K., Wohlleben, W., Hofmann, T., Gröters, S., Wiench, K., van Ravenzwaay, B., & Landsiedel, R. (2013). Comparative inhalation toxicity of multi-wall carbon nanotubes, graphene, graphite nanoplatelets and low surface carbon black. Particle and Fibre Toxicology. https://doi.org/10.1186/1743-8977-10-23
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.