Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cytokine responses of human lung cells (BEAS-2B) treated with micron-sized and nanoparticles of metal oxides compared to soil dusts

Open access
Veranth, John M, Kaser, Erin G, Veranth, Martha M, Koch, Michael, Yost, Garold S·2007·Particle and Fibre Toxicology

Abstract

BACKGROUND: The induction of cytokines by airway cells in vitro has been widely used to assess the effects of ambient and occupational particles. This study measured cytotoxicity and the release of the proinflammatory cytokines IL-6 and IL-8 by human bronchial epithelial cells treated with manufactured nano- and micron-sized particles of Al2O3, CeO2, Fe2O3, NiO, SiO2, and TiO2, with soil-derived particles from fugitive dust sources, and with the positive controls LPS, TNF-alpha, and VOSO4. RESULTS: The nano-sized particles were not consistently more potent than an equal mass of micron-sized particles of the same nominal composition for the induction of IL-6 and IL-8 secretion in the in vitro models used in this study. The manufactured pure oxides were much less potent than natural PM2.5 particles derived from soil dust, and the cells were highly responsive to the positive controls. The nano-sized particles in the media caused artifacts in the measurement of IL-6 by ELISA due to adsorption of the cytokine on the high-surface-area particles. The potency for inducing IL-6 secretion by BEAS-2B cells did not correlate with the generation of reactive oxygen species in cell-free media. CONCLUSION: Direct comparisons of manufactured metal oxide nanoparticles and previously studied types of particles and surrogate proinflammatory agonists showed that the metal oxide particles have low potency to induce IL-6 secretion in BEAS-2B cells. Particle artifacts from non-biological effects need to be considered in experiments of this type, and the limitations inherent in cell culture studies must be considered when interpreting in vitro results. This study suggests that manufactured metal oxide nanoparticles are not highly toxic to lung cells compared to environmental particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-8977-4-2

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 251

Metadata

Authors
Veranth, J. M., Kaser, E. G., Veranth, M. M., Koch, M., & Yost, G. S.
Venue
Particle and Fibre Toxicology
Published
2007
Volume
4
Issue
1
Pages
2
ISSN
1743-8977 (ISSN-L)
OpenAlex
W2136669735
Cited by
251
References
1
FWCI
12.79
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cytokine responses of human lung cells (BEAS-2B) treated with micron-sized and nanoparticles of metal oxides compared to soil dusts. https://app.cochat.ai/papers/10.1186/1743-8977-4-2
The paper
Veranth, J. M., Kaser, E. G., Veranth, M. M., Koch, M., & Yost, G. S. (2007). Cytokine responses of human lung cells (BEAS-2B) treated with micron-sized and nanoparticles of metal oxides compared to soil dusts. Particle and Fibre Toxicology. https://doi.org/10.1186/1743-8977-4-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.