Deposition and biokinetics of inhaled nanoparticles
Open accessThe DOI matches its Crossref record; 114 of the 115 references it cites were found in a registry or an index.
Abstract
Particle biokinetics is important in hazard identification and characterization of inhaled particles. Such studies intend to convert external to internal exposure or biologically effective dose, and may help to set limits in that way. Here we focus on the biokinetics of inhaled nanometer sized particles in comparison to micrometer sized ones.The presented approach ranges from inhaled particle deposition probability and retention in the respiratory tract to biokinetics and clearance of particles out of the respiratory tract. Particle transport into the blood circulation (translocation), towards secondary target organs and tissues (accumulation), and out of the body (clearance) is considered. The macroscopically assessed amount of particles in the respiratory tract and secondary target organs provides dose estimates for toxicological studies on the level of the whole organism. Complementary, microscopic analyses at the individual particle level provide detailed information about which cells and subcellular components are the target of inhaled particles. These studies contribute to shed light on mechanisms and modes of action eventually leading to adverse health effects by inhaled nanoparticles.We review current methods for macroscopic and microscopic analyses of particle deposition, retention and clearance. Existing macroscopic knowledge on particle biokinetics and microscopic views on particle organ interactions are discussed comparing nanometer and micrometer sized particles. We emphasize the importance for quantitative analyses and the use of particle doses derived from real world exposures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Concept of quantitative nanoparticle biokinetics. Nanoparticles (NP) are administered at time t = 0. From this time point on, the entire urinary and fecal excretions are collected separately. Animals are euthanized at times t1, t2, t3, etc., and organs and tissues of interest as well as the entire remaining carcass are sampled (100% balanced sampling). Samples require special preparation before chemical analysis, e.g. by inductive-coupled-plasma mass spectroscopy (ICP-MS). When nanoparticles are radio-labeled, samples will be analyzed directly, without any further preparation. Reprinted with permission from [21].](https://figures.cochat.ai/paper-figures/ee788260efb2475485b7a3373db0cd2b/deposition-and-biokinetics-of-inhaled-nanoparticles-figure-1.jpg)
![Figure 2 Micrographs of horse trachea fixed by immersion in non-polar fixative (A, B). Note that the lung lining layer (aqueous phase [asterix] and surfactant film at the air liquid interface [arrow]), has been preserved with this fixation technique. EP = epithelium, CI = cilia. Bars: (A) = 2 μm, (B) = 0.2 μm. Reprinted with permission from [21].](https://figures.cochat.ai/paper-figures/13b7448107bc43cfab649db639f065c4/deposition-and-biokinetics-of-inhaled-nanoparticles-figure-2.jpg)

![Figure 4 Elemental microanalysis of a particle in lung tissue by electron spectroscopic imaging (ESI, three window method), demonstrating that the nanoparticles (arrows) consists of titanium, adapted from [21]. The first image (A), taken at 0 eV, shows the structural details; it is slightly shifted as compared to the images used for elemental microanalyses (B-D). For elemental microanalysis, three images are taken: two below the element-specific edge in order to extrapolate a background image, at ΔE = 390eV (not shown) and ΔE = 440eV (B), respectively, and one image within the maximum of the element specific signal at ΔE = 464eV (L2,3 edge of titanium) (C). The net titanium signal (D) is calculated by subtraction of the extrapolated background image from the titanium specific signal. ESI images have reversed contrast as solely inelastically scattered electrons are used with an energy loss producing a dark field image. Hence, the obtained image reflects the titanium distribution in white pixels. Bar: 500 nm.](https://figures.cochat.ai/paper-figures/d771db9f64944c1baa1ac78574e99548/deposition-and-biokinetics-of-inhaled-nanoparticles-figure-4.jpg)
![Figure 5 Multistage tissue sampling design for EFTEM analysis of nanoparticles, adapted from [21]. Stage 1 - Lung slices: exhaustive cutting of agar embedded lung lobes (with random start) into equally thick slices [38], followed by systematic sampling of slices, e.g. every second (with random start) and Epon embedding. Stage 2 - Tissue blocks and ultrathin sections: systematic sampling (with random start) of tissue blocks from lung slices using a point counting test system and cutting of ultrathin (≤ 50 nm) sections, which are placed on 600-mesh hexagonal copper grids and stained with lead citrate and uranyl acetate. Stage 3 - Quadrats on ultrathin sections: generation of a virtual field, completely contained within the ultrathin section, at 80× magnification. Field subdivision into a predetermined number of uniform quadrats and systematic subsampling of quadrats thereof (marked in grey). Stage 4 - Fields for nanoparticle analysis: Subsampling of a group of seven adjacent fields, delimited by the hexagonal TEM grid bars, within each quadrat at 6300× magnification, using a point counting test system. Tissue analysis within these hexagonal fields for (i) the presence of particles with matching nanoparticle characteristics and (ii) particle localization within the compartments of interest. Stages 3 and 4 can equally be applied on ultrathin sections of cell pellets. Alternative to stages 3 and 4 - Fields for nanoparticle analysis are sampled by picking a random hexagonal field on the ultrathin section as starting point at 80× magnification. From there on systematic tissue analysis in horizontal and vertical direction, using the automated goniometer of the microscope.](https://figures.cochat.ai/paper-figures/79380803d2db477d8c788e4be496c2ff/deposition-and-biokinetics-of-inhaled-nanoparticles-figure-5.jpg)
![Figure 6 The respiratory tract (A) and particle deposition in a normal adult mouth breathing male human subject at rest, as a function of particle size (B). Data of bronchi are the sum of the deposition in bronchi and bronchioles. Adapted from [105] and [39] and reprinted with permission from [21].](https://figures.cochat.ai/paper-figures/c62fd67bcc274d018f65e1fb61af1b13/deposition-and-biokinetics-of-inhaled-nanoparticles-figure-6.jpg)
![Figure 7 Components of the inner surface of the lungs (A); particle deposition and immediate wetting (B) and complete displacement (C) of the deposited particle (white sphere) into the lung lining layer by surfactant. Reprinted with permission from [21].](https://figures.cochat.ai/paper-figures/85ff1ed521b549e59ce1dbbdff93e195/deposition-and-biokinetics-of-inhaled-nanoparticles-figure-7.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Lung clearance of particulate matter depends on the site of deposition as well as material characteristics including solubility and bioreactivity [9, 10].”
From Effects from a 90-day inhalation toxicity study with cerium oxide and barium sulfate nanoparticles in rats (2017) · cites this paper as [9]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In contrast, only 20% of 20-nm-sized NPs and about 30% of 70-nm-sized NP deposited during inhalation or instillation can be lavaged – see Fig. 2 [54–59].”
From Particle toxicology and health - where are we? (2019) · cites this paper as [57]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Nano-sized particles (< 100 nm) deposit in the whole respiratory tract, ending up in the alveolar region where its deposition is dominated by processes of diffusion [7–9].”
From Effects from a 90-day inhalation toxicity study with cerium oxide and barium sulfate nanoparticles in rats (2017) · cites this paper as [9]
The cited source says what the claim attributes to it.
In the citing paper
“In the alveolar space the most relevant route of particle clearance is phagocytosis by alveolar macrophages and subsequent elimination primarily via the mucociliary escalator or secondarily via the lymphatic system [9, 10].”
From Effects from a 90-day inhalation toxicity study with cerium oxide and barium sulfate nanoparticles in rats (2017) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891 · cited 1×
“Cardiovascular effects observed in these studies triggered the discussion on increased transport of inhaled ultrafine particles from the epithelial surface towards the blood circulation and subsequently to target organs, like the heart, liver and brain, eventually adversely affecting the functions of these organs [69].”
BackgroundCedervall, T., Lynch, I., Lindman, S., Berggård, T., Thulin, E., Nilsson, H., Dawson, K. A., & Linse, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608582104 · Cited by 3,281 · cited 1×
“Microparticles would be excluded from this transport because of their larger size [70-72].”
BackgroundThe unbiased estimation of number and sizes of arbitrary particles using the disector
Sterio, D. C. (1984) · Journal of Microscopy · doi:10.1111/j.1365-2818.1984.tb02501.x · Cited by 2,519 · cited 1×
“[ 35-37 ]). We have implemented this technique to count micrometer sized particles and airway macrophages in lungs by light microscopy (e.g.”
MethodPolymer conjugates as anticancer nanomedicines
Duncan, R. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1958 · Cited by 1,962 · cited 1×
“as diagnostic tools or therapeutics in medicine [6,7] health risk assessment is necessary.”
BackgroundHuman Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Protein-nanoparticle interactions
Lynch, I., & Dawson, K. A. (2008) · Nano Today · doi:10.1016/s1748-0132(08)70014-8 · Cited by 1,727
Laden, F., Schwartz, J., Speizer, F. E., & Dockery, D. W. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200503-443oc · Cited by 1,416 · cited 1×
“[ 1-5 ]). Also, for nanoparticles with anticipated beneficial use, e.g.”
BackgroundGeiser, M., Rothen-Rutishauser, B., Kapp, N., Schürch, S., Kreyling, W., Schulz, H., Semmler, M., Hof, V. I., Heyder, J., & Gehr, P. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8006 · Cited by 1,407
Self-citationLaden, F., Neas, L. M., Dockery, D. W., & Schwartz, J. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108941 · Cited by 1,296 · cited 1×
“[ 1-5 ]). Also, for nanoparticles with anticipated beneficial use, e.g.”
BackgroundUnbiased Stereology: Three-Dimensional Measurement in Microscopy
Howard, C. V., & Reed, M. (1998) · Cited by 1,149
Research works printed but not linked: 3
- [14]Weibel ER Otis AB Morphometric and stereological methods in respiratory physiology including fixation techniques Techniques in the life sciences 1984 Ireland: Elsevier Scientific Publishers 1 35
- [94]Semmler-Behnke M Fertsch S Schmid O Wenk A Kreyling WG Uptake of 1.4 mm versus 18 mm gold particles by secondary target organs is size dependent in control and pregnants rats after intertracheal or intravenoiz application Euro Nanoforum - Nanotechnology in Industrial Applications 2007 102 104 http://www.euronanoforum2007.de/download/Proceedings%20ENF2007.pdf
- [101]Kuempel ED Tran CL Castranova V Bailer AJ Lung dosimetry and risk assessment of nanoparticles: evaluating and extending current models in rats and humans Inhal Toxicol 2006 18 717 724 10.1080/08958370600747887 16774860 · DOI
Cited by
Items 401–500 of 751
Wei, S., Qi, Y., Ma, L., Liu, Y., Li, G., Sang, N., Liu, S., & Liu, Y. (2020) · Environmental Science Nano · doi:10.1039/d0en00281j · Cited by 17
Characterizations of Size-segregated Ultrafine Particles in Diesel Exhaust
Lim, J., Lim, C.-S., & Jung, S. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200356 · Cited by 17
“…11 of 16 Volume 21 | Issue 5 | 200356 ultrafine ranges of 7,8-BQ and 3-Nphe are expected to be more harmful than the larger particles (Ruckerl et al., 2011; Bakand et al., 2012) as the smaller UFPs can be deposited deeply into the human lung (Oberdörster et al., 2004; Geiser and Kreyling, 2010).”
Meldrum, K., Evans, S. J., Vogel, U. B., Tran, L., Doak, S. H., & Clift, M. J. D. (2022) · Nanotoxicology · doi:10.1080/17435390.2022.2051627 · Cited by 19
Jordakieva, G., Grabovac, I., Valic, E., Schmidt, K., Graff, A., Schuster, A., Hoffmann‐Sommergruber, K., Oberhuber, C., Scheiner, O., Goll, A., et al. (2018) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-018-0187-8 · Cited by 19
“Although UFPs readily cross the alveolo-capillary barrier the chosen circulating inflammatory markers (serum cytokine levels and haemostatic factors, as well as biochemical parameters), did not indicate any systemic reaction neither after 4 h of exposure nor 24 h after occupational UFP exposure [23, 45, 46], except fo…”
BackgroundLung Scintigraphy in the Assessment of Aerosol Deposition and Clearance
Sánchez-Crespo, A. (2018) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2018.10.015 · Cited by 18
Toxicity and Regulatory Concerns for Nanoformulations in Medicine
Gaur, N., Sharma, N., Dahiya, A., Yadav, P., Ojha, H., Goyal, R. K., & Sharma, R. K. (2020) · Wiley eBooks · doi:10.1002/9781119592990.ch13 · Cited by 19
Recent approaches of toxicity-related attributes of NMs: A systematic review
Chaudhari, N. B., Shinde, S., Havelikar, U. A., Desai, S. A., & Patel, V. P. (2025) · Nano Trends · doi:10.1016/j.nwnano.2025.100160 · Cited by 19
Liu, Q., Yang, L., Li, C., Han, L., Wilmot, J., Yang, G., Leinardi, R., Zhou, Q., Schröppel, A., Kutschke, D., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx8586 · Cited by 23
Vergaro, V., Civallero, M., Citti, C., Cosenza, M., Baldassarre, F., Cannazza, G., Pozzi, S., Sacchi, S., Fanizzi, F. P., & Ciccarella, G. (2018) · Cancers · doi:10.3390/cancers10020031 · Cited by 17
“Imaging is a powerful technique for the study of cellular interactions with extracellular substrates, including particles [38,39].”
BackgroundA system to assess the stability of airborne nanoparticle agglomerates under aerodynamic shear
Ding, Y., & Riediker, M. (2015) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2015.06.001 · Cited by 16
Bergamaschi, E. (2012) · Journal of Nanomaterials · doi:10.1155/2012/564121 · Cited by 18
“Metal nanoparticles like cobalt [13], iron oxide [14] and zinc oxide, silver [15] can release metal ions, and the role of particle dissolution in biological media, as well as its prevention by doping particle surface, has paid attention for the clearance of the particle out of the deposition sites and for the effects…”
BackgroundDing, Y., Stahlmecke, B., Jiménez, A. S., Tuinman, I. L., Kaminski, H., Kuhlbusch, T. A. J., van Tongeren, M., & Riediker, M. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1114999 · Cited by 16
“Nanoparticles have been shown to cause adverse health effects in human bodies via inhalation and subsequent translocation to secondary organs (Oberdoerster et al. 2004; Geiser and Kreyling 2010).”
BackgroundŻuberek, M., Stępkowski, T. M., Kruszewski, M. K., & Grzelak, A. (2018) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2018.02.004 · Cited by 17
Schmitz, C., Welck, J., Tavernaro, I., Grinberg, M., Rahnenführer, J., Kiemer, A. K., van Thriel, C., Hengstler, J. G., & Kraegeloh, A. (2019) · Nanotoxicology · doi:10.1080/17435390.2019.1650971 · Cited by 16
“However, Geiser and Kreyling (2010) have estimated that in vivo an alveolar surface cell maximally receives between 120 and 2400 NPs per hour, corresponding to a delivered dose of maximally 6 1010 NPs per 24 h and 106 cells.”
BackgroundThe method of depositing CeO2 nanoparticles onto a DPPC monolayer affects surface tension behaviour
Diez, M. M., Buckley, A. J., Tetley, T. D., & Smith, R. R. (2019) · NanoImpact · doi:10.1016/j.impact.2019.100186 · Cited by 16
Malinowska, K., Sicińska, P., Michałowicz, J., & Bukowska, B. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.139137 · Cited by 17
Edebeli, J., Spirig, C., Fluck, S., Fierz, M., & Anet, J. (2023) · International Journal of Public Health · doi:10.3389/ijph.2023.1605879 · Cited by 17
“As not all particle sizes are deposited in the lungs [9, 23, 38], LDSA measurements that target the dominant fraction of ambient particles with high deposition and penetration efficiency in the lungs, such as with low-cost diffusion chargers, will be more appropriate [26–29].”
BackgroundOosterwijk, M. T. T., le Feber, M., & Burello, E. (2016) · Nanotoxicology · doi:10.3109/17435390.2015.1132344 · Cited by 16
Suslova, K. G., Khokhryakov, V. F., Sokolova, A. B., & Miller, S. C. (2012) · Health Physics · doi:10.1097/hp.0b013e318234899a · Cited by 15
“The biokinetics of (238)PuO2 were found to be substantially different from similar experiments conducted in dogs using monodisperse aerosols of (239)PuO2 (Guilmette et al. 1980, 1987). The average retention for 1.7 Km AMAD aerosols of (238)PuO2 in the lung (Mewhinney and Diel 1983) are compared with the retention func…”
BackgroundResultInfluentialNanotechnological approaches toward cancer chemotherapy
Rajagopalan, R., & Yakhmi, J. V. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-46144-3.00008-8 · Cited by 21
Pulmonary Pharmacokinetics of Polymer Lung Surfactants Following Pharyngeal Administration in Mice
Kim, S., Fesenmeier, D. J., Park, S., Torregrosa‐Allen, S. E., Elzey, B. D., & Won, Y. (2022) · Biomacromolecules · doi:10.1021/acs.biomac.2c00221 · Cited by 15
Holzwarth, U., Bulgheroni, A., Gibson, P. N., Kozempel, J., Cotogno, G., Abbas, K., Simonelli, F., & Cydzik, I. (2012) · Journal of Nanoparticle Research · doi:10.1007/s11051-012-0880-y · Cited by 15
“…this area is of utmost importance (Weiss and Diabate 2011; Oberdörster et al. 2005), and intense research efforts are under way to assess the possible toxicity of nanomaterials, mostly NPs (e.g. Geiser and Kreyling 2010; De Louise et al. 2009; Mailänder and Landfester 2009; Ju-Nam and Lead 2008).”
BackgroundHenry, F. S., & Tsuda, A. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01161.2014 · Cited by 16
Montigaud, Y., Périnel, S., Dubus, J. ‐., Leclerc, L., Suau, M., Goy, C., Clotagatide, A., Prévôt, N., & Pourchez, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-42103-2 · Cited by 15
Chaudhary, K. R., Singh, K., & Singh, C. (2023) · Current Drug Delivery · doi:10.2174/0115672018265571231011093546 · Cited by 13
Kondej, D., & Sosnowski, T. R. (2019) · Journal of Nanomaterials · doi:10.1155/2019/9457683 · Cited by 14
“Retention time of carbon nanomaterials in the lungs is above 48 h [6, 11] which facilitates their penetration to the epithelial cells, blood, and lymph [12, 13].”
BackgroundMcKinley, J. M., Mueller, U. A., Atkinson, P. M., Ofterdinger, U., Jackson, C., Cox, S. F., Doherty, R., Fogarty, D. G., Egozcue, J. J., & Pawlowsky‐Glahn, V. (2020) · Applied Computing and Geosciences · doi:10.1016/j.acags.2020.100024 · Cited by 18
Reisgen, M., Thomas, K., Beilmann, V., Markert, A., Gerhards, B., Krichel, T., Schmidt, K., Kraus, T., Martin, C., Brand, P., et al. (2020) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000001905 · Cited by 14
“Particles of this size usually are not deposited in upper airways but rather travel with the air stream deeply into the lower airways up to the alveoli.(40,41)”
BackgroundCao, H., Li, B., Liu, K., Pan, L., Cui, Z. Q., Zhao, W., Zhang, H., Niu, K., Tang, N., Sun, J., et al. (2021) · Environmental Research · doi:10.1016/j.envres.2021.111356 · Cited by 15
Zhang, Y., Bello, A., Ryan, D., Demokritou, P., & Bello, D. (2022) · Nanomaterials · doi:10.3390/nano12040715 · Cited by 14
“Another factor to consider is that nanoparticles deposited in the deep lungs are cleared slowly and, as a result, may continue to induce OS [15,35,36].”
BackgroundAnderson, C. F., Wang, Q., Stern, D., Leonard, E. K., Sun, B., Fergie, K. J., Choi, C.-Y., Spangler, J. B., Villano, J., Pekosz, A. S., et al. (2022) · Matter · doi:10.1016/j.matt.2022.11.027 · Cited by 16
“After 24 h, excised lungs show a strong fluorescence signal throughout the distal lungs, suggesting migration and long-term retention of filaments, which may likely be afforded by their filamentous shape (Figure S18).(54,55) Histology of lung tissue sections taken at the 24-h time point indicates no obvious signs of s…”
BackgroundYamanda, S., Kobayashi, S., Hanagama, M., Sato, H., Suzuki, S., Ueda, S., Takahashi, T., & Yanai, M. (2016) · Internal Medicine · doi:10.2169/internalmedicine.55.6952 · Cited by 14
“The size of these earth elements in the atmosphere is usually 5 to 30 micrometers and most of them become trapped in the upper respiratory tract, but only those smaller than 5 micrometers reach the bronchioles and alveoli (3).”
BackgroundOn-field and laboratory measurement of nanoparticle emission in the wake of gasoline vehicle
Banerjee, T., & Christian, R. A. (2017) · Atmospheric Pollution Research · doi:10.1016/j.apr.2017.05.007 · Cited by 14
Assessment on Toxicity of Nanomaterials
Yang, L., Luo, X., & Luo, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814837-2.00009-3 · Cited by 17
Airborne ultrafine particle concentrations and brain cancer incidence in Canada’s two largest cities
Lloyd, M., Olaniyan, T., Ganji, A., Xu, J., Simon, L., Zhang, M., Saeedi, M., Yamanouchi, S., Wang, A., Burnett, R. T., et al. (2024) · Environment International · doi:10.1016/j.envint.2024.109088 · Cited by 14
Gosens, I., Minnema, J., Boere, A. J. F., Duistermaat, E., Fokkens, P. H. B., Vidmar, J., Loeschner, K., Bokkers, B. G. H., Costa, A. L., Peters, R., et al. (2024) · Particle and Fibre Toxicology · doi:10.1186/s12989-024-00588-4 · Cited by 16
“Nanomaterials seem to translocate from the site of intake to the blood, reach secondary organs and may accumulate there [1–5].”
BackgroundJedličková, A., Kristeková, D., Husáková, Z., Coufalík, P., Vrlíková, L., Smutná, T., Capandová, M., Alexa, L., Lusková, D., Křůmal, K., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c14571 · Cited by 14
Mines, L. W. D., Park, J. H., Mudunkotuwa, I. A., Anthony, T., Grassian, V. H., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1164828 · Cited by 13
“2009), can translocate from the respiratory system to other parts of the body (Oberd€orster et al. 1994; Geiser and Kreyling 2010), and have unique surface characteristics (Grassian et al.”
BackgroundKinetic time courses of inhaled silver nanoparticles in rats
Andriamasinoro, S. N., Dieme, D., Marie, C., Serventi, A. M., Debia, M., Haddad, S., & Bouchard, M. (2021) · Archives of Toxicology · doi:10.1007/s00204-021-03191-0 · Cited by 15
“2011; Geiser and Kreyling 2010).”
Bai, Y., Laenen, A., Haufroid, V., Nawrot, T. S., & Nemery, B. (2019) · Environment International · doi:10.1016/j.envint.2019.01.044 · Cited by 13
“This results in the presence of inclusions containing carbonaceous aggregates in the cytoplasm of macrophages (Alexis et al., 2006; Geiser, 2010).”
BackgroundSilver nanoparticle uptake in the human lung assessed through in-vitro and in-silico methods
Jalink, K., Cheng, S. S. Y., Ireland, S. B., & Meunier, M. A. F. L. (2019) · Environmental Pollution · doi:10.1016/j.envpol.2019.113880 · Cited by 14
de Lagarde, V. M., Rogez-Florent, T., Cazier, F., Dewaële, D., Cazier, F., Ollivier, A., Janona, M., Achard, S., André, V., Monteil, C., et al. (2022) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2022.113637 · Cited by 14
Movia, D., Cristo, L. D., Alnemari, R., McCarthy, J. E., Moustaoui, H., de la Chapelle, M. L., Spadavecchia, J., Volkov, Y., & Prina‐Mello, A. (2017) · Journal of Interdisciplinary Nanomedicine · doi:10.1002/jin2.25 · Cited by 17
“Risk assessment studies indeed include investigatory research on the effects of inhaled NPs (Borm & Kreyling, 2004; Geiser & Kreyling, 2010; Jud, Clift, Petri-Fink, & Rothen-Rutishauser, 2013; Klein et al., 2012; Rogueda & Traini, 2007).”
BackgroundDing, X., He, R., Zhang, T., Mei, L., Zhu, S., Wang, C., Liao, Y., Wang, D., Wang, H., Guo, J., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04255 · Cited by 15
Wu, M., Zhao, Z., Zhang, P., Wang, X., Liu, X., Ni, K., He, C., & Pan, B. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.167880 · Cited by 12
Air pollution and diseases: signaling, G protein-coupled and Toll like receptors
Cattani‐Cavalieri, I., Ostrom, K. F., Margolis, J., Ostrom, R. S., & Schmidt, M. (2025) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2025.108920 · Cited by 18
Ermolin, M. S., Fedotov, P. S., Карандашев, В. К., Dzhenloda, R. K., Ivaneev, A. I., Burkat, T. V., & Burkat, V. S. (2020) · Journal of Analytical Chemistry · doi:10.1134/s1061934820090105 · Cited by 12
Modeling indoor exposure to PM2.5 and black carbon in densely populated urban slums
Anand, A., & Phuleria, H. C. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107940 · Cited by 12
Induction of Inflammasome-dependent Pyroptosis by Carbon Black Nanoparticles
Reisetter, A. C., Stebounova, L. V., Grassian, V. H., & Monick, M. M. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.n111.238519 · Cited by 13
Maiseyeu, A., Yang, H.-Y., Ramanathan, G., Yin, F., Bard, R. L., Morishita, M., Dvonch, J. T., Wang, L., Spino, C., Mukherjee, B., et al. (2014) · Inhalation Toxicology · doi:10.3109/08958378.2013.850761 · Cited by 15
“Nevertheless, it is estimated that between 15–30% of inhaled coarse PM will reach small airways (Geiser and Kreyling, 2010).”
Double Shroud Delivery of Silica Precursor for Reducing Hexavalent Chromium in Welding Fume
Wang, J., Kalivoda, M., Guan, J., Theodore, A., Sharby, J., Wu, C., Paulson, K., & Es-Said, O. S. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.733576 · Cited by 12
Canales, C. S. C., Cazorla, J. I. M., Cazorla, R. M. M., dos Santos, A. M., Duarte, J. L., Nunes, L. O. C., Reis, T. C., Salvador, L. C., Santos‐Filho, N. A., Sábio, R. M., et al. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202503964 · Cited by 11
Kuhn, J., Vallabani, N. V. S., Montes, A. M., Juárez-Facio, A. T., Introna, M., Steimer, S. S., Patel, A., Manem, D. B., Tsyupa, B., Mancini, A., et al. (2025) · Environmental Research · doi:10.1016/j.envres.2025.121027 · Cited by 12
A Correlative Analysis of Gold Nanoparticles Internalized by A549 Cells
Böse, K., Koch, M., Cavelius, C., Kiemer, A. K., & Kraegeloh, A. (2013) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.201300308 · Cited by 11
Carsí, M., & Alonso, M. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105849 · Cited by 12
Turner, A. L., Brokamp, C., Wolfe, C., Reponen, T. A., & Ryan, P. (2022) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202108-947oc · Cited by 11
Bessa, M. J., Brandão, F., Fokkens, P. H. B., Leseman, D. L. A. C., Boere, A. J. F., Cassee, F. R., Salmatonidis, A., Viana, M., Monfort, E., Fraga, S., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23084278 · Cited by 11
Seiffert, S. B., Vennemann, A., Nordhorn, I. D., Kröger, S., Wiemann, M., & Kärst, U. (2022) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.1c00433 · Cited by 11
Improving Equitability and Inclusion for Testing and Detection of Lead Poisoning in US Children
Sobin, C. A., Gutiérrez-Vega, M., Flores‐Montoya, M. G., Rio, M. D., Alvarez, J. M., Obeng, A., Avila, J., & Hettiarachchi, G. M. (2023) · Milbank Quarterly · doi:10.1111/1468-0009.12596 · Cited by 14
Fischer, T., Tschernig, T., Drews, F., Brix, K., Meier, C., Simon, M. C., Kautenburger, R., & Schneider, M. (2020) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.11.024 · Cited by 11
Possible role of nano-sized particles in chronic tonsillitis and tonsillar carcinoma: a pilot study
Zeleník, K., Kukutschová, J., Dvořáčková, J., Bielniková, H., Peikertová, P., Čábalová, L., & Komínek, P. (2012) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-012-2069-5 · Cited by 11
“It is known from studies in animals that NPs due to their small size can be easily translocated within the body, can cross cell membranes, and can interact with subcellular structures such as mitochondria, where they have been shown to cause oxidative damage and to impair the functioning of cells in cultures [10, 11].”
BackgroundVanaki, S. M., Holmes, D. W., Suara, K. A., Jayathilake, P. G., & Brown, R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103595 · Cited by 13
Kermanizadeh, A., Jacobsen, N. R., Mroczko, A., Brown, D., & Stone, V. (2021) · Nanotoxicology · doi:10.1080/17435390.2021.2020350 · Cited by 10
“Alongside the kidneys, the liver might be responsible for the clearance of NPs from the blood (Geiser and Kreyling 2010; Semmler-Behnke et al. 2008).”
BackgroundHussain, M., Alam, K., Madl, P., & HOFMANN, W. (2012) · Environmental Monitoring and Assessment · doi:10.1007/s10661-012-2942-0 · Cited by 10
“Studies have shown that particle size and the associated surface area indeed make a difference, thereby not only significantly extending the retention time of inhaled nanosized particles in comparison with their larger siblings, but moreover releasing the adsorbed toxic freight and thus exposing biological tissues to…”
BackgroundDetection of nano- and micro-sized particles in routine biopsy material - pilot study
Dvořáčková, J., Bielniková, H., Kukutschová, J., Peikertová, P., Filip, P., Zeleník, K., Komínek, P., Uvírová, M., Přádná, J., Cermakova, Z., et al. (2012) · Biomedical Papers · doi:10.5507/bp.2012.104 · Cited by 10
Breitner, E. K., Burns, K. E., Hussain, S. M., & Comfort, K. K. (2018) · Nanotechnology · doi:10.1088/1361-6528/aabb9d · Cited by 12
Taşıt Freni Aşınma Parçacık Emisyonlarının Mikroyapısı ve Kimyasal Analizi
Güney, B., & Öz, A. (2020) · European Journal of Science and Technology · doi:10.31590/ejosat.744098 · Cited by 10
NanoSafety - Risk governance of manufactured nanoparticles
Fleischer, T., Jahnel, J., & Seitz, S. B. (2012) · Cited by 13
Meldrum, K., Moura, J. A., Doak, S. H., & Clift, M. J. D. (2022) · Nanomaterials · doi:10.3390/nano12193431 · Cited by 10
“For the quasi-ALI exposure method, this approach allows an accessible ALI exposure approach for when there are no aerosol exposure systems available [57].”
MethodHepatic toxicity assessment of cationic liposome exposure in healthy and chronic alcohol fed mice
Kermanizadeh, A., Jacobsen, N. R., Roursgaard, M., Loft, S. H., & Möller, P. (2017) · Heliyon · doi:10.1016/j.heliyon.2017.e00458 · Cited by 12
“, 2009) and alongside the kidneys might be responsible for the clearance of NMs from the blood (Geiser and Kreyling, 2010; Semmler-Behnke et al., 2008).”
BackgroundInfluentialWiemann, M., Vennemann, A., Venzago, C., Lindner, G., Schuster, T., & Krueger, N. (2021) · Nanomaterials · doi:10.3390/nano11030628 · Cited by 10
Shatkin, J. A., & Oberdörster, G. (2016) · Particle and Fibre Toxicology · doi:10.1186/s12989-016-0170-4 · Cited by 11
“Deposition fraction for CNC having largest dimension ~100-300 nm [13] = ~15 % ([19, 20]) Total alveolar surface area of human lung = 634,620 cm(2) at functional residual capacity [FRC] Mouse alveolar surface area = 526 cm(2) at FRC.”
Pioneering advancements of 2D graphene: energy and electronics applications
Alaraj, A. M., Esmaeil, A. A., Khamis, M. A., Zian, N. M., Sameh, F., Abdeldaiem, A. M., Abdelaal, E. H., Hamouda, W. J., Ghazal, S. R., El-Sayegh, H. E., et al. (2025) · Optical and Quantum Electronics · doi:10.1007/s11082-025-08534-0 · Cited by 11
Han, Z., Wang, L., Li, X., Dai, Y., Guan, X., Su, Z., Li, X., Wang, X., Li, T., & Xu, M. (2026) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2026.120007 · Cited by 11
Shifting identities of metal oxide nanoparticles: Focus on inflammation
Bhattacharya, K., Farcal, L. R., & Fadeel, B. (2014) · MRS Bulletin · doi:10.1557/mrs.2014.220 · Cited by 9
Estimation of Titanium Dioxide Intake by Diet and Stool Assessment among US Healthy Adults
Putra, C., Bello, D., Tucker, K. L., Kelleher, S. L., & Mangano, K. M. (2022) · Journal of Nutrition · doi:10.1093/jn/nxac061 · Cited by 10
Javaid, A., Imran, M., Latif, S., Hussain, N., Iqbal, H. M. N., & Bilal, M. (2022) · Journal of Materials Science · doi:10.1007/s10853-022-07679-7 · Cited by 11
“[218] Geiser M, Kreyling WG (2010) Deposition and biokinetics of inhaled nanoparticles.”
Backgroundde Lagarde, V. M., Chevalier, L., Méausoone, C., Cazier, F., Dewaële, D., Cazier, F., Janona, M., Logie, C., Achard, S., André, V., et al. (2022) · Environmental Toxicology and Pharmacology · doi:10.1016/j.etap.2023.104327 · Cited by 10
Markiewicz, K. H., Misztalewska‐Turkowicz, I., Niemirowicz, K., Bucki, R., Majcher, A. M., & Wilczewska, A. Z. (2016) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2016.12.014 · Cited by 9
Savolainen, K., & Pietroiusti, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809199-9.00005-7 · Cited by 9
Characterization of nanoparticles in aerosolized photocatalytic and regular cement
Batsungnoen, K., Hopf, N. B., Suárez, G., & Riediker, M. (2019) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1578334 · Cited by 9
A study of atherothrombotic biomarkers in welders
Ellingsen, D. G., Chashchin, M. V., Seljeflot, I., Berlinger, B., Chashchin, V., Stockfelt, L., & Thomassen, Y. (2019) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-019-01441-4 · Cited by 10
Montigaud, Y., Périnel, S., Plantier, L., Leclerc, L., Goy, C., Clotagatide, A., Prévôt, N., & Pourchez, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-54479-2 · Cited by 9
“However, anatomical and physiological features ( e.g . diameter and branching of airways, breathing frequency, tidal volume, etc.) 32,33 also represent key factors in regional deposition.”
Feasibility and Challenges of Human Health Risk Assessment for Engineered Nanomaterials
Aschberger, K., Christensen, F. M., Rasmussen, K., & Jensen, K. A. (2016) · Wiley eBooks · doi:10.1002/9781119275855.ch21 · Cited by 11
Lee, C. E., Raduka, A., Gao, N., Hussain, A., & Rezaee, F. (2024) · Tissue Barriers · doi:10.1080/21688370.2023.2300579 · Cited by 9
Particulate matter concentrations and human exposure approaches in the world microenvironments
Lazaridis, M. (2024) · Air Quality Atmosphere & Health · doi:10.1007/s11869-024-01653-9 · Cited by 8
Saraji-Bozorgzad, M. R., Bendl, J., Jeong, S., Padoan, S., Mudan, A., Etzien, U., Giocastro, B., Schade, J., Käfer, U., Streibel, T., et al. (2025) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2025.180254 · Cited by 8
Garcés, M., Marchini, T., Cáceres, L., Calabró, V., Mebert, A. M., Tuttolomondo, M. V., Vico, T. A., Vanasco, V., Tesán, F., Salgueiro, J., et al. (2021) · Toxicology · doi:10.1016/j.tox.2021.153020 · Cited by 8
Li, Y., Yu, B., Yin, L., Li, X., & Nima, Q. (2024) · Journal of Global Health · doi:10.7189/jogh.14.04039 · Cited by 11
“Third, soluble constituents (e.g. metal) and/or nano-sized particles may be able to penetrate the alveolar membrane into the bloodstream and directly affect the vascular endothelium [54–57].”
BackgroundNanomedicines via the pulmonary route: a promising strategy to reach the target?
Guérin, M., & Lepeltier, É. (2024) · Drug Delivery and Translational Research · doi:10.1007/s13346-024-01590-1 · Cited by 10
“Further barriers that need to be crossed before reaching the alveolar region is the surfactant (Surface Active Agent) located at the air–liquid interface and the mucus composing the liquid layer of the alveolar walls [53].”
Applications of Nanomaterials for Water Quality
der Bruggen, B. V. (2013) · doi:10.4155/9781909453074 · Cited by 10
Aerosol Dosimetry Modeling Using Computational Fluid Dynamics
Nordlund, M., & Kuczaj, A. K. (2015) · Methods in pharmacology and toxicology · doi:10.1007/978-1-4939-2778-4_16 · Cited by 8
Fingerprint of Lung Fluid Ultrafine Particles, a Novel Marker of Acute Lung Inflammation
Bar‐Shai, A., Alcalay, Y., Sagiv, A., Rotem-Green, M., Feigelson, S. W., Alon, R., & Fireman, E. M. (2015) · Respiration · doi:10.1159/000430824 · Cited by 8
Hinkley, G. K., & Roberts, S. M. (2013) · Particle technology series · doi:10.1007/978-3-319-00714-4_5 · Cited by 8
Nanotoxicology and Regulatory Affairs
Beer, C. (2016) · Advances in delivery science and technology · doi:10.1007/978-1-4939-3634-2_12 · Cited by 9
Departamento de Biología, F. D. C. B., Gelvez, I. M., Vargas, M. J. Q., Departamento de Química, F. D. C. B., Parra, A. Q., & Departamento de Química, F. D. C. B. (2016) · Revista Internacional de Contaminación Ambiental · doi:10.20937/rica.2016.32.04.07 · Cited by 8
Veith, L., Vennemann, A., Breitenstein, D., Engelhard, C., Hagenhoff, B., & Wiemann, M. (2018) · Nanomaterials · doi:10.3390/nano8080571 · Cited by 8
The Potential Human Health and Environmental Issues of Nanomaterials
Li, Z., Cong, H., Yan, Z., Liu, A., & Yu, B. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813351-4.00060-2 · Cited by 10
Ambient aerosols and human health: working towards a combined analytical and toxicological approach
Zimmermann, R. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5456-7 · Cited by 8
Metadata
- Authors
- Geiser, M., & Kreyling, W. G.
- Affiliations
- University of Bern (CH)
- Helmholtz Munich (DE)
- Corresponding author
- Geiser, Marianne
- Venue
- Particle and Fibre Toxicology
- Published
- 2010
- Volume
- 7
- Issue
- 1
- Pages
- 2
- ISSN
- 1743-8977 (ISSN-L)
- PMC
- PMC2826283
- OpenAlex
- W2020623049
- Cited by
- 747
- References
- 111
- Citations by year
- 2026: 44 · 2025: 37 · 2024: 44 · 2023: 36 · 2022: 39 · 2021: 56 · 2020: 51 · 2019: 50 · 2018: 40 · 2017: 57 · 2016: 48 · 2015: 52 · 2014: 54 · 2013: 45 · 2012: 48
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Particle and Fibre Toxicology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- BORIS (University Library Bern) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Site cant be reached (submittedVersion, cc-by)
- Open Access CRIS of the University of Bern
- Funders
- National Science Foundation (310030)
- Deutsche Forschungsgemeinschaft (SPP1313)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (105419, 120763, 3200B0, 310030)
- National Institutes of Health
- National Heart, Lung, and Blood Institute (HL 070542, R01HL070542)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- inhaled nanoparticles, particle deposition, particle clearance, dose estimation, subcellular targeting, exposure assessment, hazard characterization
- MeSH terms
- Air Pollutants, Animals, Animals, Laboratory, Electron Probe Microanalysis, Lung, Metabolic Clearance Rate, Particle Size, Respiratory System, Inhalation Exposure, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.