CoChat

Autoantibodies to Ezrin are an early sign of pancreatic cancer in humans and in genetically engineered mouse models

Open access
Capello, Michela, Cappello, Paola, Linty, Federica Caterina, Chiarle, Roberto, Sperduti, Isabella, Novarino, Anna, Salacone, Paola, Mandili, Giorgia, Naccarati, Alessio, Sacerdote, Carlotta, Beghelli, Stefania, Bersani, Samantha, Barbi, Stefano, Bassi, Claudio, Scarpa, Aldo, Nisticò, Paola, Giovarelli, Mirella, Vineis, Paolo, Milella, Michele, Novelli, Francesco · 2013 · Journal of Hematology & Oncology
Cited by 43

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Pancreatic Ductal Adenocarcinoma (PDAC) is a highly aggressive malignancy with only a 5% 5-year survival rate. Reliable biomarkers for early detection are still lacking. The goals of this study were (a) to identify early humoral responses in genetically engineered mice (GEM) spontaneously developing PDAC; and (b) to test their diagnostic/predictive value in newly diagnosed PDAC patients and in prediagnostic sera. Methods and results: The serum reactivity of GEM from inception to invasive cancer, and in resectable or advanced human PDAC was tested by two-dimensional electrophoresis Western blot against proteins from murine and human PDAC cell lines, respectively. A common mouse-to-human autoantibody signature, directed against six antigens identified by MALDI-TOF mass spectrometry, was determined. Of the six antigens, Ezrin displayed the highest frequency of autoantibodies in GEM with early disease and in PDAC patients with resectable disease. The diagnostic value of Ezrin-autoantibodies to discriminate PDAC from controls was further shown by ELISA and ROC analyses (P < 0.0001). This observation was confirmed in prediagnostic sera from the EPIC prospective study in patients who eventually developed PDAC (with a mean time lag of 61.2 months between blood drawing and PDAC diagnosis). A combination of Ezrin-autoantibodies with CA19.9 serum levels and phosphorylated α-Enolase autoantibodies showed an overall diagnostic accuracy of 0.96 ± 0.02. Conclusions: Autoantibodies against Ezrin are induced early in PDAC and their combination with other serological markers may provide a predictive and diagnostic signature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1756-8722-6-67

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 43

Metadata

Authors
Capello, M., Cappello, P., Linty, F. C., Chiarle, R., Sperduti, I., Novarino, A., Salacone, P., Mandili, G., Naccarati, A., Sacerdote, C., Beghelli, S., Bersani, S., Barbi, S., Bassi, C., Scarpa, A., Nisticò, P., Giovarelli, M., Vineis, P., Milella, M., & Novelli, F.
Venue
Journal of Hematology & Oncology
Published
2013-09-06
Volume
6
Issue
1
Pages
67-67
ISSN
1756-8722 (ISSN-L)
OpenAlex
W2172080880
Cited by
43
References
4
FWCI
1.58
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.