CoChat

Sources of error in emergency ultrasonography

Open access
Pinto, Antonio, Pinto, Fabio, Faggian, Angela, Rubini, Giuseppe, Caranci, Ferdinando, Macarini, Luca, Genovese, Eugenio Annibale, Brunese, Luca · 2013 · Critical Ultrasound Journal
Cited by 162

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

BACKGROUND: To evaluate the common sources of diagnostic errors in emergency ultrasonography. METHODS: The authors performed a Medline search using PubMed (National Library of Medicine, Bethesda, Maryland) for original research and review publications examining the common sources of errors in diagnosis with specific reference to emergency ultrasonography. The search design utilized different association of the following terms : (1) emergency ultrasonography, (2) error, (3) malpractice and (4) medical negligence. This review was restricted to human studies and to English-language literature. Four authors reviewed all the titles and subsequent the abstract of 171 articles that appeared appropriate. Other articles were recognized by reviewing the reference lists of significant papers. Finally, the full text of 48 selected articles was reviewed. RESULTS: Several studies indicate that the etiology of error in emergency ultrasonography is multi-factorial. Common sources of error in emergency ultrasonography are: lack of attention to the clinical history and examination, lack of communication with the patient, lack of knowledge of the technical equipment, use of inappropriate probes, inadequate optimization of the images, failure of perception, lack of knowledge of the possible differential diagnoses, over-estimation of one's own skill, failure to suggest further ultrasound examinations or other imaging techniques. CONCLUSIONS: To reduce errors in interpretation of ultrasonographic findings, the sonographer needs to be aware of the limitations of ultrasonography in the emergency setting, and the similarities in the appearances of various physiological and pathological processes. Adequate clinical informations are essential. Diagnostic errors should be considered not as signs of failure, but as learning opportunities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/2036-7902-5-s1-s1

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 22

  1. Caranci F, Cicala D, Cappabianca S, Briganti F, Brunese L, Fonio P: Orbital fractures: role of imaging. Semin Ultrasound CT MR 2012, 33(5):385–91. 10.1053/j.sult.2012.06.007 · doi:10.1053/j.sult.2012.06.007
  2. Mandato Y, Reginelli A, Galasso R, Iacobellis F, Berritto D, Cappabianca S: Errors in the radiological evaluation of the alimentary tract: part I. Semin Ultrasound CT MR 2012, 33(4):300–7. 10.1053/j.sult.2012.01.011 · doi:10.1053/j.sult.2012.01.011
  3. Caranci F, Brunese L, Reginelli A, Napoli M, Fonio P, Briganti F: Neck neoplastic conditions in the emergency setting: role of multidetector computed tomography. Semin Ultrasound CT MR 2012, 33(5):443–8. 10.1053/j.sult.2012.06.011 · doi:10.1053/j.sult.2012.06.011
  4. Martensson M, Olsson M, Segall B, Fraser AG, Winter R, Brodin LA: High incidence of defective ultrasound transducers in use in routine clinical practice. European Journal of Echocardiography 2009, 10: 389–394. 10.1093/ejechocard/jen295 · doi:10.1093/ejechocard/jen295
  5. Feldman MK, Katyal S, Blackwood MS: US Artifacts. RadioGraphics 2009, 29: 1179–1189. 10.1148/rg.294085199 · DOI · Paper page
  6. Macones AJ, Lev-Toaff AS, Macones GA, Jaffe JW, Williams VB: Legal aspects of obstetric sonography. AJR Am J Roentgenol 1989, 153: 1251–1254. 10.2214/ajr.153.6.1251 · doi:10.2214/ajr.153.6.1251
  7. Niccoli Asabella A, Renna MA, Stabile Ianora AA, Rubini D, Rubini G: Role of imaging techniques in the evaluation of chyluria. Recenti Prog Med 2012, 103(11):555–8.
  8. Cuccurullo V, Cioce F, Sica A, Iasiello F, Capasso R, Gatta G, Rubini G: Gastroenteric diseases in the third millennium: a rational approach to optimal imaging technique and patient selection. Recenti Prog Med 2012, 103(11):426–30.
  9. Mazzei MA, Guerrini S, Cioffi Squitieri N, Genovese EA, Mazzei FG, Volterrani L: Diagnosis of acute mesenteric ischemia/infarction in the era of multislice CT. Recenti Prog Med 2012, 103(11):435–7.
  10. Leopold GR: Responsibilities associated with obstetric sonography. AJR Am J Roentgenol 1989, 153: 1255–1257. 10.2214/ajr.153.6.1255 · doi:10.2214/ajr.153.6.1255
  11. Gegor CL: Obstetric ultrasound: who should perform sonograms? Birth 1992, 19: 92–99. 10.1111/j.1523-536X.1992.tb00385.x · doi:10.1111/j.1523-536x.1992.tb00385.x
  12. West RW: Radiology malpractice in the emergency room setting. Emerg Radiol 2000, 7: 14–8. 10.1007/s101400050004 · doi:10.1007/s101400050004
  13. Enderson BL, Reath DB, Meadors J, Dallas W, DeBoo JM, Maull KI: The tertiary trauma survey; a prospective study of missed injury. J Trauma 1990, 30: 666–9. 10.1097/00005373-199006000-00002 · doi:10.1097/00005373-199006000-00002
  14. Frawley PA: Missed injuries in the multiply traumatized. Aust NZ J Surg 1993, 63: 935–9. 10.1111/j.1445-2197.1993.tb01722.x · doi:10.1111/j.1445-2197.1993.tb01722.x
  15. Buduhan G, McRitchie DI: Missed injuries in patients with multiple trauma. J Trauma 2000, 49: 600–5. 10.1097/00005373-200010000-00005 · doi:10.1097/00005373-200010000-00005
  16. Stone PC, Hilton CF: Medicolegal aspects of emergency department radiology. Radiol Clin North Am 1992, 30: 495–501.
  17. Scardapane A, Pagliarulo V, Ianora AA, Pagliarulo A, Angelelli G: Contrast-enhanced multislice pneumo-CT-cystography in the evaluation of urinary bladder neoplasms. Eur J Radiol 2008, 66(2):246–52. 10.1016/j.ejrad.2007.06.005 · doi:10.1016/j.ejrad.2007.06.005
  18. Fontanarosa A, Scialpi M, Macarini L, Genovese EA, Stabile Ianora AA, Rubini G: Perineural tumor spread from the ophthalmic branch of the trigeminal nerve: a case report. Recenti Prog Med 2012, 103(11):539–41.
  19. Reginelli A, Mandato Y, Cavaliere C, Pizza NL, Russo A, Cappabianca S, Brunese L, Rotondo A, Grassi R: Three-dimensional anal endosonography in depicting anal-canal anatomy. Radiol Med 2012, 117(5):759–71. 10.1007/s11547-011-0768-4 · doi:10.1007/s11547-011-0768-4
  20. Ong CL: Pitfalls of gynaecological ultrasonography. Singapore Med J 2004, 45: 289–294.
  21. Newman-Toker DE, Camargo CA Jr, Hsieh YH, Pelletier AJ, Edlow JA: Disconnect between charted vestibular diagnoses and emergency department management decisions: a cross-sectional analysis from a nationally representative sample. Acad Emerg Med 2009, 16: 970–7. 10.1111/j.1553-2712.2009.00523.x · doi:10.1111/j.1553-2712.2009.00523.x
  22. Hughes DR, Kube E, Gable BD, Madore FE, Bahner DP: The sonographic digital portfolio: a longitudinal ultrasound image tracking program. Crit Ultrasound J 2012, 4: 15. 10.1186/2036-7902-4-15 · doi:10.1186/2036-7902-4-15

Cited by

See all 162

Metadata

Authors
Pinto, A., Pinto, F., Faggian, A., Rubini, G., Caranci, F., Macarini, L., Genovese, E. A., & Brunese, L.
Venue
Critical Ultrasound Journal
Published
2013-07-15
Volume
5
Issue
S1
Pages
S1-S1
ISSN
  • 2036-3176 (ISSN-L)
  • 2036-7902
OpenAlex
W2139748468
Cited by
162
References
29
FWCI
2.19
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.