The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Obituary: pulmonary artery catheter 1970 to 2013
Open accessAbstract
The birth of the intermittent injectate-based conventional pulmonary artery catheter (fondly nicknamed PAC) was proudly announced in the New England Journal of Medicine in 1970 by his parents HJ Swan and William Ganz. PAC grew rapidly, reaching manhood in 1986 where, in the US, he was shown to influence the management of over 40% of all ICU patients. His reputation, however, was tarnished in 1996 when Connors and colleagues suggested that he harmed patients. This was followed by randomized controlled trials demonstrating he was of little use. Furthermore, reports surfaced suggesting that he was unreliable and inaccurate. It also became clear that he was poorly understood and misinterpreted. Pretty soon after that, a posse of rivals (bedside echocardiography, pulse contour technology) moved into the neighborhood and claimed they could assess cardiac output more easily, less invasively and no less reliably. To make matter worse, dynamic assessment of fluid responsiveness (pulse pressure variation, stroke volume variation and leg raising) made a mockery of his 'wedge' pressure. While a handful of die-hard followers continued to promote his mission, the last few years of his existence were spent as a castaway until his death in 2013. His cousin (the continuous cardiac output PAC) continues to eke a living mostly in cardiac surgery patients who need central access anyway. This paper reviews the rise and fall of the conventional PAC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Singh, J. P., Evans, J. C., Levy, D., Larson, M. G., Freed, L. A., Fuller, D. L., Lehman, B., & Benjamin, E. J. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)01064-9 · Cited by 1,339
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Self-citationConnors, A. F., McCaffree, D. R., & Gray, B. A. (1983) · New England Journal of Medicine · doi:10.1056/nejm198302033080508 · Cited by 365 · cited 2×
“It was therefore widely believed that the data obtained from the PAC would allow a better understanding of the patients hemodynamic profile and that this would lead to therapeutic interventions which would improve patient outcomes [15].”
Background
Cited by
Garan, A. R., Kanwar, M., Thayer, K. L., Whitehead, E., Zweck, E., Hernandez-Montfort, J., Mahr, C., Haywood, J. L., Harwani, N. M., Wencker, D., et al. (2020) · JACC: Heart Failure · doi:10.1016/j.jchf.2020.08.012 · Cited by 405
Jones, B. E., Ying, J., Stevens, V., Haroldsen, C., He, T., Nevers, M., Christensen, M. A., Nelson, R. E., Stoddard, G. J., Sauer, B. C., et al. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.7495 · Cited by 122
Questionable benefit of the pulmonary artery catheter after cardiac surgery in high-risk patients
Chiang, Y., Hosseinian, L., Rhee, A., Itagaki, S., Cavallaro, P., & Chikwe, J. (2015) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2014.07.017 · Cited by 71
Metadata
- Authors
- Marik, P. E.
- Venue
- Annals of Intensive Care
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 3
- Issue
- 1
- Pages
- 38
- ISSN
- 2110-5820 (ISSN-L)
- OpenAlex
- W1972457707
- Cited by
- 180
- References
- 3
- Type
- other
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Obituary: pulmonary artery catheter 1970 to 2013. https://app.cochat.ai/papers/10.1186/2110-5820-3-38
- The paper
- Marik, P. E. (2013). Obituary: pulmonary artery catheter 1970 to 2013. Annals of Intensive Care. https://doi.org/10.1186/2110-5820-3-38
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.