The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
An investigation of sound levels on intensive care units with reference to the WHO guidelines
Open accessAbstract
Introduction: Patients in intensive care units (ICUs) suffer from sleep deprivation arising from nursing interventions and ambient noise. This may exacerbate confusion and ICU-related delirium. The World Health Organization (WHO) suggests that average hospital sound levels should not exceed 35 dB with a maximum of 40 dB overnight. We monitored five ICUs to check compliance with these guidelines. Methods: Sound levels were recorded in five adult ICUs in the UK. Two sound level monitors recorded concurrently for 24 hours at the ICU central stations and adjacent to patients. Sample values to determine levels generated by equipment and external noise were also recorded in an empty ICU side room. Results: Average sound levels always exceeded 45 dBA and for 50% of the time exceeded between 52 and 59 dBA in individual ICUs. There was diurnal variation with values decreasing after evening handovers to an overnight average minimum of 51 dBA at 4 AM. Peaks above 85 dBA occurred at all sites, up to 16 times per hour overnight and more frequently during the day. WHO guidelines on sound levels could be only achieved in a side room by switching all equipment off. Conclusion: All ICUs had sound levels greater than WHO recommendations, but the WHO recommended levels are so low they are not achievable in an ICU. Levels adjacent to patients are higher than those recorded at central stations. Unit-wide noise reduction programmes or mechanical means of isolating patients from ambient noise, such as earplugs, should be considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for community noise
Berglund, B., Lindvall, T., & Schwela, D. (1999) · Cited by 1,693
FREEDMAN, N. S., GAZENDAM, J., LEVAN, L., PACK, A. I., & SCHWAB, R. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.2.9912128 · Cited by 694
Gabor, J. Y., Cooper, A. B., Crombach, S. A., Lee, B., Kadikar, N., Bettger, H. E., & Hanly, P. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2201090 · Cited by 532
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 459
Sleep Deprivation in Critical Illness: Its Role in Physical and Psychological Recovery
Kamdar, B. B., Needham, D. M., & Collop, N. A. (2012) · Journal of Intensive Care Medicine · doi:10.1177/0885066610394322 · Cited by 457
Patient Perception of Sleep Quality and Etiology of Sleep Disruption in the Intensive Care Unit
FREEDMAN, N. S., KOTZER, N., & SCHWAB, R. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9806141 · Cited by 427
Noise levels in Johns Hopkins Hospital
Busch-Vishniac, I. J., West, J. E., Barnhill, C., Hunter, T., Orellana, D., & Chivukula, R. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.2118327 · Cited by 416
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Evans, G. W., & Johnson, D. (2000) · Journal of Applied Psychology · doi:10.1037//0021-9010.85.5.779 · Cited by 391
Delirium epidemiology in critical care (DECCA): an international study
Salluh, J. I., Soares, M., Teles, J. M., Ceraso, D., Raimondi, N., Nava, V. S., Blasquez, P., Ugarte, S., Ibanez-Guzman, C., Centeno, J. V., et al. (2010) · Critical Care · doi:10.1186/cc9333 · Cited by 373
Van Rompaey, B., Elseviers, M. M., Van Drom, W., Fromont, V., & Jorens, P. G. (2012) · Critical Care · doi:10.1186/cc11330 · Cited by 298
Noise, stress, and annoyance in a pediatric intensive care unit
Morrison, W. E., Haas, E. C., Shaffner, D. H., Garrett, E. S., & Fackler, J. C. (2003) · Critical Care Medicine · doi:10.1097/00003246-200301000-00018 · Cited by 281
Stressors in ICU: patients’ evaluation
Novaes, M. A. F. P., Aronovich, A., Ferraz, M. B., & Knobel, E. (1997) · Intensive Care Medicine · doi:10.1007/s001340050500 · Cited by 242
Identification and Modification of Environmental Noise in an ICU Setting
Kahn, D. M., Cook, T. E., Carlisle, C. C., Nelson, D. L., Kramer, N. R., & Millman, R. P. (1998) · Chest · doi:10.1378/chest.114.2.535 · Cited by 235
Environmental Noise as a Cause of Sleep Disruption in an Intermediate Respiratory Care Unit
Aaron, J. N., Carlisle, C. C., Carskadon, M. A., Meyer, T. J., Hill, N. S., & Millman, R. P. (1996) · Sleep · doi:10.1093/sleep/19.9.707 · Cited by 232
Witterseh, T., Wyon, D. P., & Clausen, G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00305.x · Cited by 227
Noise-induced stress as a predictor of burnout in critical care nurses.
Topf, M., & Dillon, E. (1988) · PubMed · Cited by 214
Improving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context
Görges, M., Markewitz, B. A., & Westenskow, D. R. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31819bdfbb · Cited by 211
The influence of white noise on sleep in subjects exposed to ICU noise
Stanchina, M. L., Abu-Hijleh, M., Chaudhry, B. K., Carlisle, C. C., & Millman, R. P. (2005) · Sleep Medicine · doi:10.1016/j.sleep.2004.12.004 · Cited by 201
Hu, R.-F., Jiang, X.-Y., Zeng, Y.-M., Chen, X.-Y., & Zhang, Y.-H. (2010) · Critical Care · doi:10.1186/cc8965 · Cited by 198
Characterizing noise and perceived work environment in a neurological intensive care unit
Ryherd, E. E., Waye, K. P., & Ljungkvist, L. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2822661 · Cited by 192
Experiences of critically ill patients in the ICU
Hofhuis, J. G. M., Spronk, P. E., van Stel, H. F., Schrijvers, A. J. P., Rommes, J. H., & Bakker, J. (2008) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2008.03.004 · Cited by 187
Patients' perceptions of intensive care
Simini, B. (1999) · The Lancet · doi:10.1016/s0140-6736(99)02728-2 · Cited by 166
Sleep Disruption due to Hospital Noises: A Prospective Evaluation
Buxton, O. M., Ellenbogen, J. M., Wang, W., Carballeira, A., O'Connor, S., Cooper, D., Gordhandas, A. J., McKinney, S. M., & Solet, J. M. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-12-201208070-00472 · Cited by 163
de Miranda, S., Pochard, F., Chaize, M., Mégarbane, B., Cuvelier, A., Bèle, N., Gonzalez‐Bermejo, J., Aboab, J., Lautrette, A., Lemiale, V., et al. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181feb824 · Cited by 156
Centile-based early warning scores derived from statistical distributions of vital signs
Tarassenko, L., Clifton, D. A., Pinsky, M. R., Hravnak, M., Woods, J. R., & Watkinson, P. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.03.006 · Cited by 133
Benefits of Quiet Time for Neuro-Intensive Care Patients
Dennis, C., Lee, R., Woodard, E. K., Szalaj, J. J., & Walker, C. A. (2010) · Journal of Neuroscience Nursing · doi:10.1097/jnn.0b013e3181e26c20 · Cited by 120
Earplugs improve patients’ subjective experience of sleep in critical care
Scotto, C. J., McClusky, C., Spillan, S., & Kimmel, J. (2009) · Nursing in Critical Care · doi:10.1111/j.1478-5153.2009.00344.x · Cited by 119
Patient monitoring alarms in the ICU and in the operating room
Schmid, F., Goepfert, M. S., & Reuter, D. A. (2013) · Critical Care · doi:10.1186/cc12525 · Cited by 102
Sleep disturbances in critically ill patients in ICU : how much do we know?
Boyko, Y., Ørding, H., & Jennum, P. (2012) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2012.02672.x · Cited by 100
Reducing Hospital Noise: A Review of Medical Device Alarm Management
Konkani, A., Oakley, B. A., & Bauld, T. J. (2012) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-46.6.478 · Cited by 90
Personal and environmental predictors of patient disturbance due to hospital noise.
Topf, M. (1985) · Journal of Applied Psychology · doi:10.1037/0021-9010.70.1.22 · Cited by 73
Managing alarm fatigue in cardiac care
Solet, J. M., & Barach, P. R. (2012) · Progress in Pediatric Cardiology · doi:10.1016/j.ppedcard.2011.12.014 · Cited by 67
Sleep promotion in the intensive care unit—A survey of nurses’ interventions
Eliassen, K. M., & Hopstock, L. A. (2011) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2011.03.001 · Cited by 64
Uğraş, G. A., & Öztekin, S. D. (2007) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.212.299 · Cited by 59
Gaussian process regression in vital-sign early warning systems
Clifton, L., Clifton, D. A., Pimentel, M. A. F., Watkinson, P., & Tarassenko, L. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347400 · Cited by 34
Reineck, L. A., Wallace, D. J., Barnato, A. E., & Kahn, J. M. (2013) · Critical Care · doi:10.1186/cc13033 · Cited by 31
Boehm, H., & Morast, S. (2009) · AJN American Journal of Nursing · doi:10.1097/01.naj.0000362015.55128.54 · Cited by 27
Probabilistic Patient Monitoring with Multivariate, Multimodal Extreme Value Theory
Hugueny, S., Clifton, D. A., & Tarassenko, L. (2011) · Communications in computer and information science · doi:10.1007/978-3-642-18472-7_16 · Cited by 22
The Impact of Noise in the Intensive Care Unit
Pugh, R. J., Jones, C., & Griffiths, R. (2007) · Springer eBooks · doi:10.1007/978-0-387-49518-7_85 · Cited by 17
Metadata
- Authors
- Darbyshire, J. L., & Young, J. D.
- Venue
- Critical Care
- Published
- 2013-09-03
- Volume
- 17
- Issue
- 5
- Pages
- R187-R187
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2115638287
- Cited by
- 311
- References
- 40
- FWCI
- 35.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.