The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Abstract
Background Reliance on physiological monitors to continuously “watch” patients and to alert the nurse when a serious rhythm problem occurs is standard practice on monitored units. Alarms are intended to alert clinicians to deviations from a predetermined “normal” status. However, alarm fatigue may occur when the sheer number of monitor alarms overwhelms clinicians, possibly leading to alarms being disabled, silenced, or ignored. Purpose Excessive numbers of monitor alarms and fear that nurses have become desensitized to these alarms was the impetus for a unit-based quality improvement project. Methods Small tests of change to improve alarm management were conducted on a medical progressive care unit. The types and frequency of monitor alarms in the unit were assessed. Nurses were trained to individualize patients’ alarm parameter limits and levels. Monitor software was modified to promote audibility of critical alarms. Results Critical monitor alarms were reduced 43% from baseline data. The reduction of alarms could be attributed to adjustment of monitor alarm defaults, careful assessment and customization of monitor alarm parameter limits and levels, and implementation of an interdisciplinary monitor policy. Discussion Although alarms are important and sometimes life-saving, they can compromise patients’ safety if ignored. This unit-based quality improvement initiative was beneficial as a starting point for revamping alarm management throughout the institution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Association of Critical-Care Nurses: Standards for Nursing Care of the Critically Ill
Notes, L. S. (1990) · Critical Care Nursing Quarterly · doi:10.1097/00002727-199009000-00013 · Cited by 676
Drew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F. (2004) · Circulation · doi:10.1161/01.cir.0000145144.56673.59 · Cited by 609
Poor prognosis for existing monitors in the intensive care unit
Tsien, C. L., & Fackler, J. C. (1997) · Critical Care Medicine · doi:10.1097/00003246-199704000-00010 · Cited by 309
Atzema, C., Schull, M. J., Borgundvaag, B., Slaughter, G. R. D., & Lee, C. K. (2006) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2005.05.015 · Cited by 98 · cited 1×
“An interdisciplinary alarm management task force was created and charged with (1) evaluating excessive equipment alarms that obscure and desensitize clinicians, (2) standardizing the hospital’s approach to alarm management, (3) assessing the reliability of secondary or adjunct alarm notification devices, (4) determini…”
BackgroundNurses? reactions to alarms in a neonatal intensive care unit
Bitan, Y., Meyer, J., Shinar, D., & Zmora, E. (2004) · Cognition Technology & Work · doi:10.1007/s10111-004-0162-2 · Cited by 87
Mondor, T. A., & Finley, G. A. (2003) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03017788 · Cited by 59
Clinical Alarms: Improving Efficiency and Effectiveness
Phillips, J. K., & Barnsteiner, J. (2005) · Critical Care Nursing Quarterly · doi:10.1097/00002727-200510000-00003 · Cited by 45
Human Factors in Design Safety and Management
de Waard, D., Brookhuis, K., van Egmond, R., & Boersema, T. (2005) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 16
Cited by
Early prediction of circulatory failure in the intensive care unit using machine learning
Hyland, S. L., Faltys, M., Hüser, M., Lyu, X., Gumbsch, T., Esteban, C., Bock, C., Horn, M., Moor, M., Rieck, B., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0789-4 · Cited by 477
Horsky, J., Schiff, G. D., Johnston, D., Mercincavage, L., Bell, D., & Middleton, B. (2012) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.09.002 · Cited by 289
How to develop machine learning models for healthcare
Chen, P.-H. C., Liu, Y., & Peng, L. (2019) · Nature Materials · doi:10.1038/s41563-019-0345-0 · Cited by 274
Alarm fatigue: impacts on patient safety
Ruskin, K. J., & Hueske-Kraus, D. (2015) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000260 · Cited by 226
Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183
“Widening alarm parameter default settings was evaluated in 5 studies: 1 single intervention randomized controlled trial (RCT),(36) and 4 multipleintervention, quasi-experimental studies.(31,35,37,38) In the RCT, using a lower SpO2 limit of 85% instead of the standard 90% resulted in 61% fewer alarms.”
BackgroundMethodResultInfluential
Metadata
- Authors
- Graham, K. C., & Cvach, M.
- Venue
- American Journal of Critical Care
- Publisher
- AACN Publishing
- Published
- 2010-01-01
- Volume
- 19
- Issue
- 1
- Pages
- 28-34
- ISSN
- 1062-3264 (ISSN-L)
- 1937-710X
- OpenAlex
- W2162191950
- Cited by
- 459
- References
- 8
- FWCI
- 19.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms. https://app.cochat.ai/papers/10.4037/ajcc2010651
- The paper
- Graham, K. C., & Cvach, M. (2010). Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms. American Journal of Critical Care. https://doi.org/10.4037/ajcc2010651
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.