CoChat

Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevance

Open access
Karbing, Dan S, Kjærgaard, Søren, Smith, Bram W, Espersen, Kurt, Allerød, Charlotte, Andreassen, Steen, Rees, Stephen E · 2007 · Critical Care
Cited by 177

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Introduction: Previous studies have shown through theoretical analyses that the ratio of the partial pressure of oxygen in arterial blood (PaO 2) to the inspired oxygen fraction (FiO 2) varies with the FiO 2 level. The aim of the present study was to evaluate the relevance of this variation both theoretically and experimentally using mathematical model simulations, comparing these ratio simulations with PaO 2/FiO 2 ratios measured in a range of different patients. Methods: The study was designed as a retrospective study using data from 36 mechanically ventilated patients and 57 spontaneously breathing patients studied on one or more occasions. Patients were classified into four disease groups (normal, mild hypoxemia, acute lung injury and acute respiratory distress syndrome) according to their PaO 2/FiO 2 ratio. On each occasion the patients were studied using four to eight different FiO 2 values, achieving arterial oxygen saturations in the range 85–100%. At each FiO 2 level, measurements were taken of ventilation, of arterial acid–base and of oxygenation status. Two mathematical models were fitted to the data: a one-parameter 'effective shunt' model, and a two-parameter shunt and ventilation/perfusion model. These models and patient data were used to investigate the variation in the PaO 2/FiO 2 ratio with FiO 2, and to quantify how many patients changed disease classification due to variation in the PaO 2/FiO 2 ratio. An F test was used to assess the statistical difference between the two models' fit to the data. A confusion matrix was used to quantify the number of patients changing disease classification. Results: The two-parameter model gave a statistically better fit to patient data (P < 0.005). When using this model to simulate variation in the PaO 2/FiO 2 ratio, disease classification changed in 30% of the patients when changing the FiO 2 level. Conclusion: The PaO 2/FiO 2 ratio depends on both the FiO 2 level and the arterial oxygen saturation level. As a minimum, the FiO 2 level at which the PaO 2/FiO 2 ratio is measured should be defined when quantifying the effects of therapeutic interventions or when specifying diagnostic criteria for acute lung injury and acute respiratory distress syndrome. Alternatively, oxygenation problems could be described using parameters describing shunt and ventilation/perfusion mismatch.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc6174

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Karbing, D. S., Kjærgaard, S., Smith, B. W., Espersen, K., Allerød, C., Andreassen, S., & Rees, S. E.
Venue
Critical Care
Published
2007-11-07
Volume
11
Issue
6
Pages
R118-R118
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2041780055
Cited by
177
References
3
FWCI
3.12
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.