Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO2), oxygen consumption, and microvascular reperfusion and reactivity. The methodologies for assessing StO2 during a VOT, however, are very inconsistent in the literature and, consequently, results vary from study to study, making data comparison difficult and potentially inadequate. Two major aspects concerning the inconsistent methodology are measurement site and probe spacing. To address these issues, we investigated the effects of probe spacing and measurement site using 15 mm and 25 mm probe spacings on the thenar and the forearm in healthy volunteers and quantified baseline, ischemic, reperfusion, and hyperemic VOT-derived StO2 variables. METHODS: StO2 was non-invasively measured in the forearm and thenar in eight healthy volunteers during 3-minute VOTs using two InSpectra tissue spectrometers equipped with a 15 mm probe or a 25 mm probe. VOT-derived StO2 traces were analyzed for base-line, ischemic, reperfusion, and hyperemic parameters. Data were categorized into four groups: 15 mm probe on the forearm (F15 mm), 25 mm probe on the forearm (F25 mm), 15 mm probe on the thenar (T15 mm), and 25 mm probe on the thenar (T25 mm). RESULTS: Although not apparent at baseline, probe spacing and measurement site significantly influenced VOT-derived StO2 variables. For F15 mm, F25 mm, T15 mm, and T25 mm, StO2 ownslope was -6.4 +/- 1.7%/minute, -10.0 +/- 3.2%/minute, -12.5 +/- 3.0%/minute, and -36.7 +/- 4.6%/minute, respectively. StO2 upslope was 105 +/- 34%/minute, 158 +/- 55%/minute, 226 +/- 41%/minute, and 713 +/- 101%/minute, and the area under the hyperemic curve was 7.4 +/- 3.8%.minute, 10.1 +/- 4.9%.minute, 12.6 +/- 4.4%.minute, and 21.2 +/- 2.7%.minute in these groups, respectively. Furthermore, the StO2 parameters of the hyperemic phase of the VOT, such as the area under the curve, significantly correlated to the minimum StO2 during ischemia. CONCLUSIONS: NIRS measurements in combination with a VOT are measurement site-dependent and probe-dependent. Whether this dependence is anatomy-, physiology-, or perhaps technology-related remains to be elucidated. Our study also indicated that reactive hyperemia depends on the extent of ischemic insult.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The differences between monitors are likely to be in part associated with the measurement site and spacing of the probes. 16,17”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [16]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“It has been suggested that the ischemic stimulus is more extensive in the muscle compared with the subdermal tissue; 16 therefore, the greater dynamic range reported by the MOXY may be related to the SR method enabling a greater muscle contribution than the SRS despite the smaller source:detector separation in the MOXY.”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microvascular Blood Flow Is Altered in Patients with Sepsis
De Backer, D., Creteur, J., Preiser, J.-C., Dubois, M.-J., & Vincent, J.-L. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200109-016oc · Cited by 1,473
The microcirculation is the motor of sepsis.
İnce, C. (2005) · Critical Care · doi:10.1186/cc3753 · Cited by 804 · cited 1×
“Introduction It is now well established that tissue oxygen utilization and regional microcirculatory oxygen transport properties are severely affected during sepsis and shock [1-9].”
Self-citationMicrocirculatory oxygenation and shunting in sepsis and shock
Ince, C., & Sinaasappel, M. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00031 · Cited by 542 · cited 1×
“Introduction It is now well established that tissue oxygen utilization and regional microcirculatory oxygen transport properties are severely affected during sepsis and shock [1-9].”
Self-citationTrzeciak, S., McCoy, J. V., Phillip Dellinger, R., Arnold, R. C., Rizzuto, M., Abate, N. L., Shapiro, N. I., Parrillo, J. E., Hollenberg, S. M., & on behalf of the Microcirculatory Alterations in Resuscitation and Shock (MARS) investigators (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1193-6 · Cited by 488
The prognostic value of muscle StO2 in septic patients
Creteur, J., Carollo, T., Soldati, G., Buchele, G., De Backer, D., & Vincent, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0739-3 · Cited by 355 · cited 6×
“…StO 2 variables as reported in the literature, however, varied widely between the studies using a 15 mm probe and the studies using a 25 mm probe [9-12, 14 , 16-18 The potential mechanisms by which the VOT-derived StO 2 traces might be different when measured by the 15 mm or 25 mm probes could…”
InfluentialBoerma, E. C., Mathura, K. R., van der Voort, P. H., Spronk, P. E., & Ince, C. (2005) · Critical Care · doi:10.1186/cc3809 · Cited by 308 · cited 1×
“Introduction It is now well established that tissue oxygen utilization and regional microcirculatory oxygen transport properties are severely affected during sepsis and shock [1-9].”
Self-citationFink, M. P. (2001) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70161-5 · Cited by 302 · cited 1×
“It is now well established that tissue oxygen utilization and regional microcirculatory oxygen transport properties are severely affected during sepsis and shock [1-9].”
Impairments in microvascular reactivity are related to organ failure in human sepsis
Doerschug, K. C., Delsing, A. S., Schmidt, G. A., & Haynes, W. G. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01237.2006 · Cited by 242
Microvascular function and rheologic changes in hyperdynamic sepsis
Astiz, M. E., DeGent, G. E., Lin, R. Y., & Rackow, E. C. (1995) · Critical Care Medicine · doi:10.1097/00003246-199502000-00011 · Cited by 208 · cited 1×
“Introduction It is now well established that tissue oxygen utilization and regional microcirculatory oxygen transport properties are severely affected during sepsis and shock [1-9].”
Gómez, H., Torres, A., Polanco, P., Kim, H. K., Zenker, S., Puyana, J. C., & Pinsky, M. R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1145-1 · Cited by 206 · cited 6×
“Both probes have been used in various studies with varying results [ 9-12 ].”
Influential
Cited by
Items 101–105 of 105
Park, S., Mathew, J., Leifer, E., Osgood, S., Gomez, C., Ackerman, H. C., & Kanthi, Y. M. (2026) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae4862
Şavluk, Ö. F., Yılmaz, A. A., Tomrukçu, F., Yavuz, Y., Işıldak, F. U., Genç, F. A., Arıcı, Ş., Karakuş, Ö. S., Corbacioglu, S., Gürcü, M. E., et al. (2026) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2026.05.001
Schwartz, J. L., Khan, A., & Bentley, R. F. (2026) · Physiological Reports · doi:10.14814/phy2.71085
“Further, NIRS-VOT parameters have also been shown to be unaffected by limb dominance (Bezemer et al., 2009).”
Metadata
- Authors
- Bezemer, R., Lima, A., Myers, D., Klijn, E., Heger, M., Goedhart, P. T., Bakker, J., & Ince, C.
- Affiliations
- Erasmus MC (NL)
- Amsterdam UMC Location University of Amsterdam (NL)
- Corresponding author
- Bezemer, Rick
- Venue
- Critical Care
- Published
- 2009-11-30
- Volume
- 13
- Issue
- S5
- Pages
- S4-S4
- ISSN
- 1364-8535 (ISSN-L)
- PMC
- PMC2786106
- OpenAlex
- W2148764621
- Semantic Scholar
- 3f0ec5507416f2a8098fd2dd25787173ef7790e5
- Cited by
- 103
- References
- 18
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 4 · 2023: 7 · 2022: 7 · 2021: 5 · 2020: 5 · 2019: 11 · 2018: 5 · 2017: 2 · 2016: 10 · 2015: 7 · 2014: 6 · 2013: 6 · 2012: 9
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Critical Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- UvA-DARE (University of Amsterdam) (publishedVersion, other-oa)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- tissue oxygen saturation, vascular occlusion test, near-infrared spectroscopy, probe spacing, measurement site, forearm, microcirculation, reperfusion, hyperemia, ischemia, oxygen consumption, healthy volunteers, methodological consistency, critically ill patients, microvascular reactivity, microvascular reperfusion, measurement reproducibility
- MeSH terms
- Adult, Female, Forearm, Humans, Male, Oxygen Consumption, Vascular Diseases, Spectroscopy, Near-Infrared, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.