CoChat

Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers

Open access

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO2), oxygen consumption, and microvascular reperfusion and reactivity. The methodologies for assessing StO2 during a VOT, however, are very inconsistent in the literature and, consequently, results vary from study to study, making data comparison difficult and potentially inadequate. Two major aspects concerning the inconsistent methodology are measurement site and probe spacing. To address these issues, we investigated the effects of probe spacing and measurement site using 15 mm and 25 mm probe spacings on the thenar and the forearm in healthy volunteers and quantified baseline, ischemic, reperfusion, and hyperemic VOT-derived StO2 variables. METHODS: StO2 was non-invasively measured in the forearm and thenar in eight healthy volunteers during 3-minute VOTs using two InSpectra tissue spectrometers equipped with a 15 mm probe or a 25 mm probe. VOT-derived StO2 traces were analyzed for base-line, ischemic, reperfusion, and hyperemic parameters. Data were categorized into four groups: 15 mm probe on the forearm (F15 mm), 25 mm probe on the forearm (F25 mm), 15 mm probe on the thenar (T15 mm), and 25 mm probe on the thenar (T25 mm). RESULTS: Although not apparent at baseline, probe spacing and measurement site significantly influenced VOT-derived StO2 variables. For F15 mm, F25 mm, T15 mm, and T25 mm, StO2 ownslope was -6.4 +/- 1.7%/minute, -10.0 +/- 3.2%/minute, -12.5 +/- 3.0%/minute, and -36.7 +/- 4.6%/minute, respectively. StO2 upslope was 105 +/- 34%/minute, 158 +/- 55%/minute, 226 +/- 41%/minute, and 713 +/- 101%/minute, and the area under the hyperemic curve was 7.4 +/- 3.8%.minute, 10.1 +/- 4.9%.minute, 12.6 +/- 4.4%.minute, and 21.2 +/- 2.7%.minute in these groups, respectively. Furthermore, the StO2 parameters of the hyperemic phase of the VOT, such as the area under the curve, significantly correlated to the minimum StO2 during ischemia. CONCLUSIONS: NIRS measurements in combination with a VOT are measurement site-dependent and probe-dependent. Whether this dependence is anatomy-, physiology-, or perhaps technology-related remains to be elucidated. Our study also indicated that reactive hyperemia depends on the extent of ischemic insult.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc8002

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

Metadata

Authors
Bezemer, R., Lima, A., Myers, D., Klijn, E., Heger, M., Goedhart, P. T., Bakker, J., & Ince, C.
Affiliations
  • Erasmus MC (NL)
  • Amsterdam UMC Location University of Amsterdam (NL)
Corresponding author
Bezemer, Rick
Venue
Critical Care
Published
2009-11-30
Volume
13
Issue
S5
Pages
S4-S4
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2148764621
Cited by
103
References
18
Citations by year
2026: 5 · 2025: 3 · 2024: 4 · 2023: 7 · 2022: 7 · 2021: 5 · 2020: 5 · 2019: 11 · 2018: 5 · 2017: 2 · 2016: 10 · 2015: 7 · 2014: 6 · 2013: 6 · 2012: 9
FWCI
5.04
Type
journal article
Language
en
Open access
Licence
Locations
  • Critical Care (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • UvA-DARE (University of Amsterdam) (publishedVersion, other-oa)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
tissue oxygen saturation, vascular occlusion test, near-infrared spectroscopy, probe spacing, measurement site, forearm, microcirculation, reperfusion, hyperemia, ischemia, oxygen consumption, healthy volunteers, methodological consistency, critically ill patients, microvascular reactivity, microvascular reperfusion, measurement reproducibility
MeSH terms
Adult, Female, Forearm, Humans, Male, Oxygen Consumption, Vascular Diseases, Spectroscopy, Near-Infrared, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.