Continuous glucose monitors prove highly accurate in critically ill children
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Introduction: Hyperglycemia is associated with increased morbidity and mortality in critically ill patients and strict glycemic control has become standard care for adults. Recent studies have questioned the optimal targets for such management and reported increased rates of iatrogenic hypoglycemia in both critically ill children and adults. The ability to provide accurate, real-time continuous glucose monitoring would improve the efficacy and safety of this practice in critically ill patients. The aim of our study is to determine if a continuous, interstitial glucose monitor will correlate with blood glucose values in critically ill children. Methods: We evaluated 50 critically ill children age 6 weeks to 16 years old with a commercially available continuous glucose monitor (CGM; Medtronic Guardian ® ). CGM values and standard blood glucose (BG) values were compared. During the study, no changes in patient management were made based on CGM readings alone. Results: Forty-seven patients had analyzable CGM data. A total of 1,555 CGM and routine BG measurements were compared using Clarke error grid and Bland-Altman analysis. For all readings, 97.9% were within clinically acceptable agreement. The mean absolute relative difference between CGM and BG readings was 15.3%. For the 1,555 paired CGM and BG measurements, there is a statistically significant linear relationship between CGM values and BG ( P <.0001). A high degree of clinical agreement existed in three subpopulation analyses based on age, illness severity, and support measures. This included some of our smallest patients (that is, <12 months old), those who required vasopressors, and those who were treated for critical illness hyperglycemia. Conclusions: In one of the largest studies to date, in a highly vulnerable ICU population, CGM values have a clinically acceptable correlation with the BG values now used diagnostically and therapeutically. Our data contest the theoretical concerns posed by some regarding CGM use in the ICU. The existing medical evidence may now support a role for CGM devices in the identification and management of hyperglycemia in diverse ICU settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119 · cited 1×
“Several recent, large multi-center randomized controlled trials (RCTs), including the Glucontrol, VISEP, and NICE-SUGAR trials, have been plagued with unacceptably high rates of hypoglycemia in strict control arms [5-7].”
BackgroundIntensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639
Intensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921 · cited 1×
“Several recent, large multi-center randomized controlled trials (RCTs), including the Glucontrol, VISEP, and NICE-SUGAR trials, have been plagued with unacceptably high rates of hypoglycemia in strict control arms [5-7].”
BackgroundPreiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911 · cited 1×
“Several recent, large multi-center randomized controlled trials (RCTs), including the Glucontrol, VISEP, and NICE-SUGAR trials, have been plagued with unacceptably high rates of hypoglycemia in strict control arms [5-7].”
BackgroundVlasselaers, D., Milants, I., Desmet, L., Wouters, P. J., Vanhorebeek, I., van den Heuvel, I., Mesotten, D., Casaer, M. P., Meyfroidt, G., Ingels, C., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60044-1 · Cited by 554 · cited 4×
“would be preferable to keep the risk of hypoglycaemia to a minimum [4].”
BackgroundInfluential
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Self-citationContinuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Validation of the continuous glucose monitoring sensor in preterm infants
Beardsall, K., Vanhaesebrouck, S., Ogilvy-Stuart, A. L., Vanhole, C., vanWeissenbruch, M., Midgley, P., Thio, M., Cornette, L., Ossuetta, I., Palmer, C. R., et al. (2013) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/archdischild-2012-301661 · Cited by 82
Management of type 1 diabetes in the hospital setting
Mendez, C. E., & Umpierrez, G. E. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0919-7 · Cited by 34
Metadata
- Authors
- Bridges, B. C., Preissig, C. M., Maher, K. O., & Rigby, M. R.
- Venue
- Critical Care
- Published
- 2010-10-06
- Volume
- 14
- Issue
- 5
- Pages
- R176-R176
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2128156839
- Cited by
- 69
- References
- 5
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.