Cardiac output monitoring: an integrative perspective
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Cardiac output monitoring in the critically ill patient is standard practice in order to ensure tissue oxygenation [ 1 ] and has been traditionally accomplished using the pulmonary artery catheter (PAC). In recent years, however, the value of PAC has been questioned with some suggesting that its use might not only be unnecessary but also potentially harmful [ 1 ]. This notion, together with the availability of new less invasive cardiac output measuring devices, has markedly decreased the widespread use of the PAC [ 2 ]. Today, various devices are available to measure or estimate cardiac output using different methods. Some of these less invasive devices track stroke volume (SV) continuously and provide dynamic indices of fluid responsiveness, others allow assessment of volumetric preload variables, and some also provide continuous measurement of central venous saturation via the use of proprietary catheters that are attached to the same monitor. All these variables - together with cardiac output - may result in an improved hemodynamic assessment of the critically ill patient. However, it is important to appreciate that each device has its inherent limitations and that no cardiac output monitoring device can change patient outcome unless its use is coupled with an intervention that by itself has been associated with improved patient outcomes. Therefore, the concept of hemodynamic optimization is increasingly recognized as a cornerstone in the management of critically ill patients and has been shown to be associated with improved outcome in the perioperative [ 3 ] and in the intensive care unit (ICU) [ 4 ] setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2 retracted
Boldt, J., Lenz, M., Kumle, B., et al. (1998) · Intensive Care Medicine · doi:10.1007/s001340050536 · Cited by 148 · cited 1×
“Although the majority of physicians use CVP in order to guide fl uid therapy [34], several studies have shown lack of correlation between CVP and SV [35,36].”
BackgroundRetractedMayer, J., Boldt, J., Poland, R., Peterson, A. J., & Manecke, G. R. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.03.003 · Cited by 142 · cited 1×
“This has resulted in an improved performance primarily in perioperative setting [15, 16].”
BackgroundRetractedEarly goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · cited 2×
“As far as its clinical utility is concerned, ScvO2 has been used as a resuscitation endpoint in patients with severe sepsis and septic shock [43].”
BackgroundMethodThe Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516 · cited 1×
“The different functional hemodynamic variables have been shown to be able to predict fluid responsiveness in various studies [39], whereas static preload variables have not [40].”
BackgroundMarik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272 · cited 1×
“The different functional hemodynamic variables have been shown to be able to predict fluid responsiveness in various studies [39], whereas static preload variables have not [40].”
BackgroundHarvey, S., Harrison, D. A., Singer, M., Ashcroft, J., Jones, C. M., Elbourne, D., Brampton, W., Williams, D., Young, D., & Rowan, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67061-4 · Cited by 1,126
Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800 · cited 1×
“Although the majority of physicians use CVP in order to guide fluid therapy [34], several studies have shown lack of correlation between CVP and SV [35, 36].”
BackgroundPearse, R., Dawson, D., Fawcett, J., Rhodes, A., Grounds, R. M., & Bennett, E. D. (2005) · Critical Care · doi:10.1186/cc3887 · Cited by 698 · cited 1×
“Th e LiDCOTMplus system, in combination with a hemodynamic treatment protocol (targeting an oxygen delivery > 600 ml/min/m2, was shown to be associated with reduced complications and length of hospital stay in patients after major general surgery [14].”
BackgroundPrognostic Value of Extravascular Lung Water in Critically Ill Patients
Sakka, S. G., Klein, M., Reinhart, K., & Meier‐Hellmann, A. (2002) · CHEST Journal · doi:10.1378/chest.122.6.2080 · Cited by 672 · cited 1×
“EVLW on the other hand can be used to diff erentiate between cardiac versus non-cardiac pulmonary edema, and has been identifi ed as an independent predictor of survival in critically ill patients [38].”
Background
Cited by
Consensus guidelines for enhanced recovery after gastrectomy
Mortensen, K., Nilsson, M., Slim, K., Schäfer, M., Mariette, C., Braga, M., Carli, F., Demartines, N., Griffin, S. M., Lassen, K., et al. (2014) · British Journal of Surgery · doi:10.1002/bjs.9582 · Cited by 767
Metadata
- Authors
- Alhashemi, J. A., Cecconi, M., & Hofer, C. K.
- Venue
- Critical Care
- Published
- 2011
- Volume
- 15
- Issue
- 2
- Pages
- 214
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2031965614
- Cited by
- 202
- References
- 41
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac output monitoring: an integrative perspective. https://app.cochat.ai/papers/10.1186/cc9996
- The paper
- Alhashemi, J. A., Cecconi, M., & Hofer, C. K. (2011). Cardiac output monitoring: an integrative perspective. Critical Care. https://doi.org/10.1186/cc9996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.