Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis

Open access
Zhao, Lei, Tian, Zhuang, Fang, Quan·2016·BMC Cardiovascular Disorders

Abstract

BACKGROUND: This study is a systematic review and meta-analysis of the diagnostic value of cardiovascular magnetic resonance (CMR) in cardiac amyloidosis (CA). METHODS: A wide variety of electronic databases were searched for studies of CMR that reported the diagnostic accuracy in patients with suspected CA. Research manuscripts were subjected to further systematic review and meta-analysis. Methodological evaluation was performed under the guidance of the Quality Assessment of Diagnostic Accuracy Studies -2 (QUADAS-2). Heterogeneity was assessed, and a random-effects model was used to assess the diagnostic effects of CMR on pooled sensitivity, pooled specificity, and summary receiver operating characteristics (SROC). RESULTS: Seven studies that reported the performance of CMR for CA were included in the present systematic review, among which five studies (257 patients) that evaluated the diagnostic accuracy of late gadolinium enhancement (LGE) CMR were analyzed in the present meta-analysis. Heterogeneity was observed only in specificity. A summary sensitivity and specificity of 85 % (95 % CI: 77-91 %) and 92 % (95 % CI: 83-97 %) indicated a high diagnostic accuracy of LGE for CA. The AUC of SROC curve was 0.9530, suggesting that LGE is an effective way of diagnosing patients with possible cardiac involvement in amyloidosis. CONCLUSIONS: LGE-CMR seems to have a relatively high diagnostic accuracy for amyloidosis patients with possible cardiac involvement. Combined CMR techniques may provide important information for the selection of suitable therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12872-016-0311-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 160

Metadata

Authors
Zhao, L., Tian, Z., & Fang, Q.
Venue
BMC Cardiovascular Disorders
Published
2016-06-07
Volume
16
Issue
1
Pages
129-129
ISSN
1471-2261 (ISSN-L)
OpenAlex
W2411080321
Cited by
160
References
2
FWCI
0.69
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s12872-016-0311-6
The paper
Zhao, L., Tian, Z., & Fang, Q. (2016). Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis. BMC Cardiovascular Disorders. https://doi.org/10.1186/s12872-016-0311-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.