Endoscopic ultrasonography with fine-needle aspiration for histological diagnosis of solid pancreatic masses: a meta-analysis of diagnostic accuracy studies
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous studies have demonstrated that endoscopic ultrasound-fine needle aspiration (EUS-FNA) is a reliable tool for diagnosing pancreatic lesions; however, the reported sensitivity and specificity vary greatly across studies. The aim of this study was to pool the existing literature and assess the overall performance of EUS-FNA in the diagnosis of solid pancreatic lesions. METHODS: A systematic search of MEDLINE, Cochrane Database for Systematic Reviews, and EMBASE was performed to identify original and review articles published between January 1995 and January 2014 that reported the accuracy of EUS-FNA in the diagnosis of pancreatic masses. Quality of the included studies was assessed using the quality assessment of diagnosis accuracy studies score tool. Meta-DiSc software was used to calculate the pooled sensitivity and specificity, positive and negative likelihood ratios, and to construct the summary receiver operating characteristics curve. RESULTS: Twenty studies involving a total of 2,761 patients were included in the study. The pooled sensitivity and specificity of EUS-FNA in the diagnosis of solid pancreatic lesions were 90.8 % [95 % confidence interval (CI), 89.4-92 %] and 96.5 % (95 % CI, 94.8-97.7 %), respectively. The positive and negative likelihood ratios were 14.8 (95 % CI, 8.0-27.3) and 0.12 (95 % CI, 0.09-0.16), respectively. The overall diagnostic accuracy was 91.0 %. CONCLUSIONS: Our findings suggest that EUS-FNA has high sensitivity and specificity in the diagnosis of solid pancreatic lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Murray, T., Ward, E., Samuels, A., Tiwari, R. C., Ghafoor, A., Feuer, E. J., & Thun, M. J. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.1.10 · Cited by 4,186
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Warshaw, A. L., & Castillo, C. F.-D. (1992) · New England Journal of Medicine · doi:10.1056/nejm199202133260706 · Cited by 1,198
Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment
Wiersema, M., Vilmann, P., Giovannini, M., Chang, K., & Wiersema, L. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70164-1 · Cited by 1,131 · cited 1×
“Operator experience has been proposed as one of the most significant factors that affect the accuracy of EUS-FNA [7, 26, 29], which is a demonstrated significant predictor of diagnostic accuracy in pancreatic lesions in the multivariable model [30].”
BackgroundChang, K. J., Nguyen, P., Erickson, R. A., Durbin, T. E., & Katz, K. D. (1997) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(97)70149-4 · Cited by 568 · cited 8×
“As shown in Table 2, actual complications of EUS-FNA procedures occurred in 35 of 1,760 patients in 15 studies that mentioned complications [7, 8, 10–13, 15, 16, 19, 20, 22, 23, 25, 26], mainly abdominal pain, pancreatitis, hematoma, bleeding at needle sites and fever (not accompanied by other symptoms).”
BackgroundInfluentialEndosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses
Harewood, G. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04133-3 · Cited by 414
Voss, M., Hammel, P., Molas, G., Palazzo, L., Dancour, A., O'Toole, D., Terris, B., Degott, C., Bernades, P., & Ruszniewski, P. (2000) · Gut · doi:10.1136/gut.46.2.244 · Cited by 376
Agarwal, B., Abu-Hamda, E., Molke, K. L., Correa, A. M., & Ho, L. (2004) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2004.04177.x · Cited by 328 · cited 7×
“Raut et al. 2003 [16] 4/233 2 Duodenal perforation (n = 2), abdominal pain (n = 1), pancreatitis (n = 1) Afify et al. 2003 [17] Unknown - - Agarwal et al. 2004 [18] 2/81 2.5 Abdominal pain (n = 2) Ryozawa et al. 2005 [19] 0 0 No complications reported Eloubeidi et al. 2007 [20] 11/547 2 Acute…”
BackgroundInfluentialEndoscopic Ultrasonography–Guided Fine-Needle Aspiration Biopsy of Suspected Pancreatic Cancer
Gress, F., Gottlieb, K., Sherman, S., & Lehman, G. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-6-200103200-00010 · Cited by 316 · cited 1×
“…et al. 1997 [23] 1/44 2 Fever (n = 1) Bentz et al. 1998 [24] Unknown - - Voss et al. 2000 [12] 5/90 5 Bleeding (n = 4), abdominal pain (n = 1) Gress et al. 2001 [13] 3/102 2.9 Gastric mucosal bleeding (n = 2), pancreatitis (n = 1) Ylagan et al. 2002 [14] 1/91 1 Acute pancreatitis (n = 1).”
InfluentialOptimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis
LeBlanc, J. K., Ciaccia, D., Al-Assi, M. T., McGrath, K., Imperiale, T., Tao, L.-C., Vallery, S., DeWitt, J., Sherman, S., & Collins, E. (2004) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(03)02863-3 · Cited by 282 · cited 1×
“specimens [35], and a recent report recommended that seven needle passes would be necessary to ensure a highly accurate diagnosis of solid pancreatic lesions by EUS-FNA [36].”
Background
Cited by
Polkowski, M., Jenssen, C., Kaye, P., Carrara, S., Deprez, P., Gines, A., Fernández-Esparrach, G., Eisendrath, P., Aithal, G., Arcidiacono, P., et al. (2017) · Endoscopy · doi:10.1055/s-0043-119219 · Cited by 370
Impact of endoscopic ultrasonography on diagnosis of pancreatic cancer
Kitano, M., Yoshida, T., Itonaga, M., Tamura, T., Hatamaru, K., & Yamashita, Y. (2019) · Journal of Gastroenterology · doi:10.1007/s00535-018-1519-2 · Cited by 316
Cost-effectiveness of Pancreatic Cancer Surveillance in High-Risk Individuals: An Economic Analysis
Corral, J. E., Das, A., Bruno, M. J., & Wallace, M. B. (2019) · Pancreas · doi:10.1097/mpa.0000000000001268 · Cited by 66
Yamao, K., Takenaka, M., Ishikawa, R., Okamoto, A., Yamazaki, T., Nakai, A., Omoto, S., Kamata, K., Minaga, K., Matsumoto, I., et al. (2020) · Diagnostics · doi:10.3390/diagnostics10070445 · Cited by 58
Applications of gene pair methods in clinical research: advancing precision medicine
Wu, C., Xie, X., Yang, X., Du, M., Lin, H., & Huang, J. (2025) · Molecular Biomedicine · doi:10.1186/s43556-025-00263-w · Cited by 10
Metadata
- Authors
- Banafea, O., Mghanga, F. P., Zhao, J., Zhao, R., & Zhu, L.
- Venue
- BMC Gastroenterology
- Published
- 2016-08-31
- Volume
- 16
- Issue
- 1
- Pages
- 108-108
- ISSN
- 1471-230X (ISSN-L)
- OpenAlex
- W2507733246
- Cited by
- 170
- References
- 28
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.