Automated prostate cancer detection via comprehensive multi-parametric magnetic resonance imaging texture feature models
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Prostate cancer is the most common form of cancer and the second leading cause of cancer death in North America. Auto-detection of prostate cancer can play a major role in early detection of prostate cancer, which has a significant impact on patient survival rates. While multi-parametric magnetic resonance imaging (MP-MRI) has shown promise in diagnosis of prostate cancer, the existing auto-detection algorithms do not take advantage of abundance of data available in MP-MRI to improve detection accuracy. The goal of this research was to design a radiomics-based auto-detection method for prostate cancer via utilizing MP-MRI data. METHODS: In this work, we present new MP-MRI texture feature models for radiomics-driven detection of prostate cancer. In addition to commonly used non-invasive imaging sequences in conventional MP-MRI, namely T2-weighted MRI (T2w) and diffusion-weighted imaging (DWI), our proposed MP-MRI texture feature models incorporate computed high-b DWI (CHB-DWI) and a new diffusion imaging modality called correlated diffusion imaging (CDI). Moreover, the proposed texture feature models incorporate features from individual b-value images. A comprehensive set of texture features was calculated for both the conventional MP-MRI and new MP-MRI texture feature models. We performed feature selection analysis for each individual modality and then combined best features from each modality to construct the optimized texture feature models. RESULTS: The performance of the proposed MP-MRI texture feature models was evaluated via leave-one-patient-out cross-validation using a support vector machine (SVM) classifier trained on 40,975 cancerous and healthy tissue samples obtained from real clinical MP-MRI datasets. The proposed MP-MRI texture feature models outperformed the conventional model (i.e., T2w+DWI) with regard to cancer detection accuracy. CONCLUSIONS: Comprehensive texture feature models were developed for improved radiomics-driven detection of prostate cancer using MP-MRI. Using a comprehensive set of texture features and a feature selection method, optimal texture feature models were constructed that improved the prostate cancer auto-detection significantly compared to conventional MP-MRI texture feature models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · cited 1×
“For the classifier, we used the SVM implemented in [52].”
MethodTextural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886 · cited 4×
“These features include first- and second-order statistical features (Haralick [32, 33]), steerable Gabor filter features [34], and Kirsch filter features [35].”
MethodInfluentialPeng, H., Long, F., & Ding, C. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.159 · Cited by 10,544 · cited 2×
“For feature extraction function, we used the maximum relevance, minimum redundancy (mRMR) technique [40], which is based on maximum relevance and minimum”
Method(1968) · American Association of Industrial Nurses Journal · doi:10.1177/216507996801601208 · Cited by 8,798
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084 · cited 1×
“The proposed MP-MRI texture feature models are the first attempt in designing comprehensive quantitative feature sequences or radiomics as a high dimensional mineable feature space that can be used as both detection and prognostic tools for prostate cancer [43].”
BackgroundDecoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Габор, Д. (1946) · Journal of the IEE · Cited by 5,036
Screening and Prostate-Cancer Mortality in a Randomized European Study
Schröder, F. H., Hugosson, J., Roobol, M. J., Tammela, T. L. J., Ciatto, S., Nelen, V., Kwiatkowski, M., Lujan, M., Lilja, H., Zappa, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810084 · Cited by 4,014
Mortality Results from a Randomized Prostate-Cancer Screening Trial
Andriole, G. L., Crawford, E. D., Grubb, R. L., Buys, S. S., Chia, D., Church, T. R., Fouad, M. N., Gelmann, E. P., Kvale, P. A., Reding, D. J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810696 · Cited by 2,906
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Texture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141 · cited 1×
“, Kirsch [35]), fractal based features [36], run length matrices [37], and discrete cosine transform (DCT) [38].”
BackgroundProstate-Cancer Mortality at 11 Years of Follow-up
Schröder, F. H., Hugosson, J., Roobol, M. J., Tammela, T. L. J., Ciatto, S., Nelen, V., Kwiatkowski, M., Lujan, M., Lilja, H., Zappa, M., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113135 · Cited by 1,245
Texture analysis of SAR sea ice imagery using gray level co-occurrence matrices
Soh, L.-K., & Tsatsoulis, C. (1999) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.752194 · Cited by 1,223 · cited 4×
“These features include first- and second-order statistical features (Haralick [32, 33]), steerable Gabor filter features [34], and Kirsch filter features [35].”
MethodInfluentialSystematic Review of Complications of Prostate Biopsy
Loeb, S., Vellekoop, A., Ahmed, H. U., Catto, J., Emberton, M., Nam, R., Rosario, D. J., Scattoni, V., & Lotan, Y. (2013) · European Urology · doi:10.1016/j.eururo.2013.05.049 · Cited by 1,073
Computer determination of the constituent structure of biological images
Kirsch, R. A. (1971) · Computers and Biomedical Research · doi:10.1016/0010-4809(71)90034-6 · Cited by 606 · cited 6×
“Most of the reviewed methods utilized texture features that are based on one or more of the following methods: First-Order statistical method, second-order statistical methods or Co-Occurrence Matrices [32, 33], steerable Gabor filter [34], Gradient based features (e.g., Kirsch [35]), fractal based features [36], run…”
BackgroundMethodInfluentialNam, R. K., Saskin, R., Lee, Y., Liu, Y., Law, C., Klotz, L. H., Loblaw, D. A., Trachtenberg, J., Stanimirovic, A., Simor, A. E., et al. (2013) · Journal of Urology · doi:10.1016/j.juro.2012.11.015 · Cited by 592
Prostate Specific Antigen Best Practice Statement: 2009 Update
Greene, K. L., Albertsen, P. C., Babaian, R. J., Carter, H. B., Gann, P. H., Han, M., Kuban, D. A., Sartor, A. O., Stanford, J. L., Zietman, A., et al. (2009) · Journal of Urology · doi:10.1016/j.juro.2009.07.093 · Cited by 517
Türkbey, B., Mani, H., Shah, V. P., Rastinehad, A. R., Bernardo, M., Pohida, T. J., Pang, Y., Daar, D., Benjamin, C. J., McKinney, Y. L., et al. (2011) · The Journal of Urology · doi:10.1016/j.juro.2011.07.013 · Cited by 497 · cited 1×
“Moreover, studies have demonstrated the ability ofMP-MRI to direct biopsy with MRI/Ultrasound fusion techniques [19] and to predict Gleason score [16] and tumour volume [20].”
BackgroundNam, R. K., Saskin, R., Lee, Y., Liu, Y., Law, C., Klotz, L. H., Loblaw, D. A., Trachtenberg, J., Stanimirovic, A., Simor, A. E., et al. (2010) · Journal of Urology · doi:10.1016/j.juro.2009.11.043 · Cited by 402
Gevaert, O., Xu, J., Hoang, C. D., Leung, A. N., Xu, Y., Quon, A., Rubin, D. L., Napel, S., & Plevritis, S. K. (2012) · Radiology · doi:10.1148/radiol.12111607 · Cited by 398
Fractal feature analysis and classification in medical imaging
Chen, C.-C., DaPonte, J. S., & Fox, M. D. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24861 · Cited by 390 · cited 1×
“, Kirsch [35]), fractal based features [36], run length matrices [37], and discrete cosine transform (DCT) [38].”
BackgroundVourganti, S., Rastinehad, A., Yerram, N. K., Nix, J., Volkin, D., Hoang, A., Turkbey, B., Gupta, G. N., Kruecker, J., Linehan, W. M., et al. (2012) · Journal of Urology · doi:10.1016/j.juro.2012.08.025 · Cited by 247 · cited 1×
“Moreover, studies have demonstrated the ability ofMP-MRI to direct biopsy with MRI/Ultrasound fusion techniques [19] and to predict Gleason score [16] and tumour volume [20].”
BackgroundAutomated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI
Madabhushi, A., Feldman, M. D., Metaxas, D. N., Tomaszeweski, J., & Chute, D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.859208 · Cited by 184 · cited 4×
“Similar set of features used in [29] was used with a random forest classifier for detection where the evaluation was performed on 29 patient studies; accuracy of 86% was achieved.”
BackgroundMethodInfluentialArumainayagam, N., Ahmed, H. U., Moore, C. M., Freeman, A., Allen, C., Sohaib, S. A., Kirkham, A. P. S., van der Meulen, J., & Emberton, M. (2013) · Radiology · doi:10.1148/radiol.13120641 · Cited by 174
Empirical estimates of prostate cancer overdiagnosis by age and prostate-specific antigen
Vickers, A. J., Sjoberg, D. D., Ulmert, D., Vertosick, E., Roobol, M. J., Thompson, I. M., Heijnsdijk, E. A. M., de Koning, H. J., Atoria-Swartz, C., Scardino, P. T., et al. (2014) · BMC Medicine · doi:10.1186/1741-7015-12-26 · Cited by 142
Vos, P., Barentsz, J. O., Karssemeijer, N., & Huisman, H. J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/6/1527 · Cited by 137 · cited 1×
“Different features were extracted from different MR images; second-order statistical and Gabor features from T2w, multi-scale blobness filter from ADC images, and curve fitting and pharmacokinetic features from DCE images [31].”
MethodHambrock, T., Vos, P. C., Hulsbergen–van de Kaa, C. A., Barentsz, J. O., & Huisman, H. J. (2013) · Radiology · doi:10.1148/radiol.12111634 · Cited by 123 · cited 1×
“Similar to the work reported in [55], clinical assessment of the proposed autodetection model will be performed to evaluate its effect on the clinicians’ performance.”
ResultBittencourt, L. K., Barentsz, J. O., de Miranda, L. C. D., & Gasparetto, E. L. (2011) · European Radiology · doi:10.1007/s00330-011-2269-1 · Cited by 115
Multi-kernel graph embedding for detection, Gleason grading of prostate cancer via MRI/MRS
Tiwari, P., Kurhanewicz, J. V., & Madabhushi, A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.10.004 · Cited by 112 · cited 1×
“[13] proposed a method that combines structural and metabolic imaging data for separating benign versus cancerous and high Gleason score versus low Gleason grade regions in MP-MRI that includes T2w and magnetic resonance spectroscopy (MRS).”
MethodBae, H., Yoshida, S., Matsuoka, Y., Nakajima, H., Ito, E., Tanaka, H., Oya, M., Nakayama, T., Takeshita, H., Kijima, T., et al. (2013) · International Urology and Nephrology · doi:10.1007/s11255-013-0557-1 · Cited by 47
Wong, A. M., Glaister, J., Cameron, A., & Haider, M. A. (2013) · BMC Medical Imaging · doi:10.1186/1471-2342-13-26 · Cited by 29 · cited 4×
“The CDI signal is obtained via signal mixing as follows [42]:”
BackgroundMethodInfluentialSelf-citationWang, C., Goatman, K. A., MacGillivray, T., Beveridge, E., Koutraki, Y. G., Boardman, J. P., Stirrat, C., Sparrow, S. A., Moore, E. J., Paraky, R., et al. (2015) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2015.7164061 · Cited by 28
Shafiee, M. J., Haider, S. A., Wong, A. M., Lui, D., Cameron, A., Modhafar, A., Fieguth, P., & Haider, M. A. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2376781 · Cited by 28 · cited 1×
“CHB-DWI is an alternative approach to obtain high-b DWI in which a computational model is used to reconstruct DWI at high b-values using low b-value DWI acquisitions [14, 51].”
MethodSelf-citationGlaister, J., Cameron, A., Wong, A., & Haider, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6345957 · Cited by 19 · cited 5×
“In this paper, we propose new MP-MRI texture feature models that in addition to T2w and conventional DWI images, incorporate computed high-b diffusionweighted imaging (CHB-DWI) [14] and the recently proposed correlated diffusion imaging (CDI) [42].”
BackgroundMethodInfluentialSelf-citationMulti-Image Texture Analysis in Classification of Prostatic Tissues from MRI. Preliminary Results
Duda, D., Krętowski, M., Mathiéu, R., de Crevoisier, R., & Bézy‐Wendling, J. (2014) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-06593-9_13 · Cited by 16
Rezaeilouyeh, H., Mahoor, M. H., Zhang, J. J., Rosa, F. G. L., Chang, S., & Werahera, P. N. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945103 · Cited by 7 · cited 1×
“ROIbased approach [29, 39, 54] is similar to pixel-based with the difference that it uses larger neighborhoods of pixels (e.”
Method
Cited by
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Radiomics-based Prognosis Analysis for Non-Small Cell Lung Cancer
Zhang, Y., Oikonomou, A., Wong, A., Haider, M. A., & Khalvati, F. (2017) · Scientific Reports · doi:10.1038/srep46349 · Cited by 269
Self-citationProstate cancer detection using deep convolutional neural networks
Yoo, S., Gujrathi, I., Haider, M. A., & Khalvati, F. (2019) · Scientific Reports · doi:10.1038/s41598-019-55972-4 · Cited by 230
Self-citation
Metadata
- Authors
- Khalvati, F., Wong, A., & Haider, M. A.
- Venue
- BMC Medical Imaging
- Published
- 2015-08-05
- Volume
- 15
- Issue
- 1
- Pages
- 27-27
- ISSN
- 1471-2342 (ISSN-L)
- OpenAlex
- W1771067798
- Cited by
- 159
- References
- 37
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.