The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study
Open accessAbstract
BACKGROUND: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. METHODS: Body composition, included appendicular lean mass divided by height squared (ALM/ht(2)) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. RESULTS: A total of 219 subjects were enrolled in this study (mean age: 43.7 ± 19.1 years old, 51.6% of women). For the ALM/ht(2), reliability of the test-retest of the BIA was high with an ICC of 0.89 (95%CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95%CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht(2) assessed by DXA and BIA was low (ICC = 0.37 (95%CI: 0.25-0.48)). Mean ALM/ht(2) was 9.19 ± 1.39 kg/m(2) with BIA and 7.34 ± 1.34 kg/m(2) with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht(2) assessed by DXA. CONCLUSIONS: Although our results show that the measure of ALM/ht(2) by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht(2) compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarcopenia: European consensus on definition and diagnosis
Cruz-Jentoft, A. J., Baeyens, J. P., Bauer, J. M., Boirie, Y., Cederholm, T., Landi, F., Martin, F. C., Michel, J.-P., Rolland, Y., Schneider, S. M., et al. (2010) · Age and Ageing · doi:10.1093/ageing/afq034 · Cited by 11,601 · cited 2×
“The formula used for this calculation is as follows: n ¼ 2σ2½QG 1−α2 þ QG 1−βð Þ 2 Δ2 where, σ 2 is the variance difference between the result of appendicular lean mass obtained by BIA and the result obtained by DXA in a pilot study (=3.252 kg); α is the type I error = 0.05; β is the type II error = 0.1; Δ 2 is the ma…”
BackgroundInfluentialRoberts, H. C., Denison, H. J., Martin, H. J., Patel, H. P., Syddall, H., Cooper, C., & Sayer, A. A. (2011) · Age and Ageing · doi:10.1093/ageing/afr051 · Cited by 3,001
A questionnaire for the assessment of leisure time physical activities
Taylor, H. L., Jacobs, D. R., Schucker, B., Knudsen, J., Leon, A. S., & Debacker, G. (1978) · Journal of Chronic Diseases · doi:10.1016/0021-9681(78)90058-9 · Cited by 1,848
The evaluation of body composition: A useful tool for clinical practice
Thibault, R., & Pichard, C. (2012) · Annals of Nutrition and Metabolism · doi:10.1159/000334879 · Cited by 193
Haapala, I., Hirvonen, A., Niskanen, L., Uusitupa, M., Kröger, H., Alhava, E., & Nissinen, A. (2002) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1475-097x.2002.00447.x · Cited by 46 · cited 1×
“Indeed, bioelectrical impedance analysis offers an inexpensive and easy to perform alternative to assess body composition [9].”
Background
Cited by
Sarcopenia in daily practice: assessment and management
Beaudart, C., McCloskey, E., Bruyère, O., Cesari, M., Rolland, Y., Rizzoli, R., Araujo de Carvalho, I., Amuthavalli Thiyagarajan, J., Bautmans, I., Bertière, M.-C., et al. (2016) · BMC Geriatrics · doi:10.1186/s12877-016-0349-4 · Cited by 850
Self-citationPitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
Self-citationSergi, G., De Rui, M., Stubbs, B., Veronese, N., & Manzato, E. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0622-6 · Cited by 291
“For muscle mass estimation also the use of MF-BIA has been proposed, but it has shown a low concordance with reference DXA method [29].”
New Frontiers of Body Composition in Sport
Lukaski, H., & Raymond-Pope, C. J. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1373-5881 · Cited by 149
Beaudart, C., Bruyère, O., Geerinck, A., Hajaoui, M., Scafoglieri, A., Perkisas, S., Bautmans, I., Gielen, E., Reginster, J.-Y., & Buckinx, F. (2020) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2019.09.012 · Cited by 113
Self-citation
Metadata
- Authors
- Buckinx, F., Reginster, J.-Y., Dardenne, N., Croisiser, J.-L., Kaux, J.-F., Beaudart, C., Slomian, J., & Bruyère, O.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2015-03-18
- Volume
- 16
- Issue
- 1
- Pages
- 60-60
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W2034363245
- Cited by
- 207
- References
- 5
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study. https://app.cochat.ai/papers/10.1186/s12891-015-0510-9
- The paper
- Buckinx, F., Reginster, J.-Y., Dardenne, N., Croisiser, J.-L., Kaux, J.-F., Beaudart, C., Slomian, J., & Bruyère, O. (2015). Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-015-0510-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.