Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A systematic review on the use of topical hemostats in trauma and emergency surgery

Open access
Chiara, Osvaldo, Cimbanassi, Stefania, Bellanova, Giovanni, Chiarugi, Massimo, Mingoli, Andrea, Olivero, Giorgio, Ribaldi, Sergio, Tugnoli, Gregorio, Basilicò, Silvia, Bindi, Francesca, Briani, Laura, Renzi, Federica, Chirletti, Piero, Di Grezia, Giuseppe, Martino, Antonio, Marzaioli, Rinaldo, Noschese, Giuseppe, Portolani, Nazario, Ruscelli, Paolo, Zago, Mauro, Sgardello, Sebastian, Stagnitti, Franco, Miniello, Stefano · 2018 · BMC Surgery

Abstract

BACKGROUND: A wide variety of hemostats are available as adjunctive measures to improve hemostasis during surgical procedures if residual bleeding persists despite correct application of conventional methods for hemorrhage control. Some are considered active agents, since they contain fibrinogen and thrombin and actively participate at the end of the coagulation cascade to form a fibrin clot, whereas others to be effective require an intact coagulation system. The aim of this study is to provide an evidence-based approach to correctly select the available agents to help physicians to use the most appropriate hemostat according to the clinical setting, surgical problem and patient's coagulation status. METHODS: The literature from 2000 to 2016 was systematically screened according to PRISMA [Preferred Reporting Items for Systematic Reviews and Meta-Analyses] protocol. Sixty-six articles were reviewed by a panel of experts to assign grade of recommendation (GoR) and level of evidence (LoE) using the GRADE [Grading of Recommendations Assessment, Development and Evaluation] system, and a national meeting was held. RESULTS: Fibrin adhesives, in liquid form (fibrin glues) or with stiff collagen fleece (fibrin patch) are effective in the presence of spontaneous or drug-induced coagulation disorders. Mechanical hemostats should be preferred in patients who have an intact coagulation system. Sealants are effective, irrespective of patient's coagulation status, to improve control of residual oozing. Hemostatic dressings represent a valuable option in case of external hemorrhage at junctional sites or when tourniquets are impractical or ineffective. CONCLUSIONS: Local hemostatic agents are dissimilar products with different indications. A knowledge of the properties of each single agent should be in the armamentarium of acute care surgeons in order to select the appropriate product in different clinical conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12893-018-0398-z

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 158

Metadata

Authors
Chiara, O., Cimbanassi, S., Bellanova, G., Chiarugi, M., Mingoli, A., Olivero, G., Ribaldi, S., Tugnoli, G., Basilicò, S., Bindi, F., Briani, L., Renzi, F., Chirletti, P., Di Grezia, G., Martino, A., Marzaioli, R., Noschese, G., Portolani, N., Ruscelli, P., Zago, M., Sgardello, S., Stagnitti, F., & Miniello, S.
Venue
BMC Surgery
Published
2018-08-29
Volume
18
Issue
1
Pages
68-68
ISSN
1471-2482 (ISSN-L)
OpenAlex
W2889122693
Cited by
158
References
1
FWCI
2.91
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A systematic review on the use of topical hemostats in trauma and emergency surgery. https://app.cochat.ai/papers/10.1186/s12893-018-0398-z
The paper
Chiara, O., Cimbanassi, S., Bellanova, G., Chiarugi, M., Mingoli, A., Olivero, G., Ribaldi, S., Tugnoli, G., Basilicò, S., Bindi, F., Briani, L., Renzi, F., Chirletti, P., Di Grezia, G., Martino, A., Marzaioli, R., Noschese, G., Portolani, N., Ruscelli, P., . . . Miniello, S. (2018). A systematic review on the use of topical hemostats in trauma and emergency surgery. BMC Surgery. https://doi.org/10.1186/s12893-018-0398-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.