A systematic review on the use of topical hemostats in trauma and emergency surgery
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A wide variety of hemostats are available as adjunctive measures to improve hemostasis during surgical procedures if residual bleeding persists despite correct application of conventional methods for hemorrhage control. Some are considered active agents, since they contain fibrinogen and thrombin and actively participate at the end of the coagulation cascade to form a fibrin clot, whereas others to be effective require an intact coagulation system. The aim of this study is to provide an evidence-based approach to correctly select the available agents to help physicians to use the most appropriate hemostat according to the clinical setting, surgical problem and patient's coagulation status. METHODS: The literature from 2000 to 2016 was systematically screened according to PRISMA [Preferred Reporting Items for Systematic Reviews and Meta-Analyses] protocol. Sixty-six articles were reviewed by a panel of experts to assign grade of recommendation (GoR) and level of evidence (LoE) using the GRADE [Grading of Recommendations Assessment, Development and Evaluation] system, and a national meeting was held. RESULTS: Fibrin adhesives, in liquid form (fibrin glues) or with stiff collagen fleece (fibrin patch) are effective in the presence of spontaneous or drug-induced coagulation disorders. Mechanical hemostats should be preferred in patients who have an intact coagulation system. Sealants are effective, irrespective of patient's coagulation status, to improve control of residual oozing. Hemostatic dressings represent a valuable option in case of external hemorrhage at junctional sites or when tourniquets are impractical or ineffective. CONCLUSIONS: Local hemostatic agents are dissimilar products with different indications. A knowledge of the properties of each single agent should be in the armamentarium of acute care surgeons in order to select the appropriate product in different clinical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
The cochrane database of systematic reviews
Geddes, J. (1996) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(96)90063-x · Cited by 5,989
Cochrane Database of Systematic Reviews
(2011) · Progress in Neurology and Psychiatry · doi:10.1002/pnp.208 · Cited by 4,667
Grading Strength of Recommendations and Quality of Evidence in Clinical Guidelines
Guyatt, G., Gutterman, D., Baumann, M. H., Addrizzo-Harris, D., Hylek, E. M., Phillips, B., Raskob, G., Lewis, S. Z., & Schünemann, H. (2006) · Chest · doi:10.1378/chest.129.1.174 · Cited by 1,220
A Special Report on the Chitosan-based Hemostatic Dressing: Experience in Current Combat Operations
Wedmore, I., McManus, J. G., Pusateri, A. E., & Holcomb, J. B. (2006) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000199392.91772.44 · Cited by 598
Spotnitz, W. D. (2014) · ISRN Surgery · doi:10.1155/2014/203943 · Cited by 355 · cited 6×
“The spray tip is particularly useful when the surgical setting requires a large and uniform deposition of the product [1, 7].”
BackgroundInfluentialBulger, E. M., Snyder, D., Schoelles, K., Gotschall, C., Dawson, D., Lang, E., Sanddal, N. D., Butler, F. K., Fallat, M., Taillac, P., et al. (2014) · Prehospital Emergency Care · doi:10.3109/10903127.2014.896962 · Cited by 260
Tissue adhesives for closure of surgical incisions
Dumville, J. C., Coulthard, P., Worthington, H. V., Riley, P., Patel, N., Darcey, J., Esposito, M., van der Elst, M., & van Waes, O. J. F. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004287.pub4 · Cited by 257
QuikClot Use in Trauma for Hemorrhage Control: Case Series of 103 Documented Uses
Rhee, P., Brown, C., Martin, M., Salim, A., Plurad, D., Green, D., Chambers, L., Demetriades, D., Velmahos, G., & Alam, H. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31812f6dbc · Cited by 224 · cited 3×
“The first series of clinical experience with QC has been described by Rhee and coworkers [58], who reported the results of a survey on 103 patients, both in military and civilian settings.”
Kheirabadi, B. S., Edens, J. W., Terrazas, I. B., Estep, J. S., Klemcke, H. G., Dubick, M. A., & Holcomb, J. B. (2009) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31819634a1 · Cited by 198
Chapman, W. C., Singla, N., Genyk, Y., McNeil, J. W., Renkens, K. L., Reynolds, T. C., Murphy, A., & Weaver, F. A. (2007) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2007.03.020 · Cited by 175 · cited 1×
“[4] 2007 Phase 3, randomized, double-blind Recombinant thrombin has comparable efficacy, a similar safety profile, and is considerably less immunogenic than bovine thrombin when used for surgical hemostasis 1C”
BackgroundSurgical sealant for preventing air leaks after pulmonary resections in patients with lung cancer
Belda-Sanchís, J., Serra-Mitjans, M., Iglesias Sentis, M., & Rami, R. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003051.pub3 · Cited by 163 · cited 3×
“[32] 2010 Cochrane review Surgical sealants have some beneficial effects in reducing postoperative air leaks, but their systematic use cannot be recommended at the moment 1A”
InfluentialComparison of a New Fibrin Sealant With Standard Topical Hemostatic Agents
Schwartz, M. (2004) · Archives of Surgery · doi:10.1001/archsurg.139.11.1148 · Cited by 160 · cited 3×
“[6] compared the effectiveness of Crosseal® with that of different products, including various collagens, cellulose, gelatin and thrombin for the control of bile loss.”
BackgroundMethodResultFigueras, J., Lladó, L., Miró, M., Ramos, E., Torras, J., Fabregat, J., & Serrano, T. (2007) · Annals of Surgery · doi:10.1097/01.sla.0000245846.37046.57 · Cited by 148 · cited 5×
“While some studies [16, 19] indicate that fibrin sealants may have a potential role in sealing bile ducts, thereby decreasing the total fluid drainage and its bilirubin concentration, others did not [17, 18].”
InfluentialTissue adhesives in gastrointestinal anastomosis: a systematic review
Vakalopoulos, K. A., Daams, F. D., Wu, Z., Timmermans, L., Jeekel, J. J., Kleinrensink, G., van der Ham, A. C., & Lange, J. F. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2012.12.043 · Cited by 140
Efficacy of an Absorbable Fibrin Sealant Patch (TachoSil) After Distal Pancreatectomy
Montorsi, M., Zerbi, A., Bassi, C., Capussotti, L., Coppola, R., & Sacchi, M. M. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e318272dec0 · Cited by 136 · cited 3×
“Montorsi and coll [27] in a prospective, open, randomized study on 275 patients requiring distal pancreatectomy (DP) compared the fistula rate between patients in whom TachoSil® was applied on the pancreatic stump and those who did not received the fibrin patch.”
InfluentialComparison of regenerated and non-regenerated oxidized cellulose hemostatic agents
Lewis, K. M., Spazierer, D., Urban, M. D., Lin, L., Redl, H. R., & Goppelt, A. (2013) · European surgery. Supplement/European surgery · doi:10.1007/s10353-013-0222-z · Cited by 134
Coselli, J. S., Bavaria, J. E., Fehrenbacher, J. W., Stowe, C. L., Macheers, S., & Gundry, S. R. (2003) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(03)00376-4 · Cited by 128 · cited 5×
“[52] 2003 Prospective randomized The bovine serum albumin and glutaraldehyde sealant is a safe and effective adjunct to reduce the occurrence of anastomotic site bleeding in cardiovascular surgery 2A”
InfluentialNew hemostatic agents in the combat setting
Cox, E. D., Schreiber, M. A., McManus, J. G., Wade, C. E., & Holcomb, J. B. (2009) · Transfusion · doi:10.1111/j.1537-2995.2008.01988.x · Cited by 126
Safety of Chitosan Bandages in Shellfish Allergic Patients
Waibel, K. H., Haney, B., Moore, M., Whisman, B. A., & Gomez, R. A. (2011) · Military Medicine · doi:10.7205/milmed-d-11-00150 · Cited by 122
Kim, K. D., & Wright, N. M. (2011) · Spine · doi:10.1097/brs.0b013e3181fdb4db · Cited by 117
Allen, M. S., Wood, D. E., Hawkinson, R. W., Harpole, D. H., McKenna, R. J., Walsh, G. L., Vallières, E., Miller, D. L., Nichols, F. C., Smythe, W. R., et al. (2004) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2003.10.049 · Cited by 113
Medical Devices: Evidence and Research
(2020) · Medical Devices Evidence and Research · doi:10.2147/mder · Cited by 105
Fibrin Sealants in Dura Sealing: A Systematic Literature Review
Esposito, F., Angileri, F. F., Kruse, P., Cavallo, L. M., Solari, D., Esposito, V., Tomasello, F., & Cappabianca, P. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151533 · Cited by 101
Dhillon, S. (2011) · Drugs · doi:10.2165/11207700-000000000-00000 · Cited by 95
Briceño, J., Naranjo, Á., Ciria, R., Díaz-Nieto, R., Sánchez-Hidalgo, J.-M., Luque, A., Rufián, S., & López‐Cillero, P. (2010) · Archives of Surgery · doi:10.1001/archsurg.2010.62 · Cited by 83
Multiple uses of fibrin sealant for nervous system treatment following injury and disease
Biscola, N. P., Cartarozzi, L. P., Ulian-Benitez, S., Barbizan, R., de Castro, M. V., Spejo, A. B., Ferreira, R. S., Barraviera, B., & de Oliveira, A. L. R. (2017) · The Journal of venomous animals and toxins including tropical diseases · doi:10.1186/s40409-017-0103-1 · Cited by 79
Öllinger, R., Mihaljevic, A., Schuhmacher, C., Bektas, H., Vondran, F., Kleine, M., Sainz-Barriga, M., Weiss, S., Knebel, P., Pratschke, J., et al. (2013) · HPB · doi:10.1111/hpb.12009 · Cited by 71 · cited 2×
“[48] demonstrated the effectiveness of the oxidized cellulose-PEG-based sealant VerisetTM in achieving hemostasis after open hepatic surgery faster than the control device (median time to hemostasis:1.”
Fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery
Cheng, Y., Ye, M., Xiong, X., Peng, S., Wu, H. M., Cheng, N., & Gong, J. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009621.pub2 · Cited by 68
Menovsky, T., Plazier, M., Rasschaert, R., Maas, A. I. R., Parizel, P. M., & Verbeke, S. (2011) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-0031-1284394 · Cited by 58 · cited 4×
“[69] 2011 Case reports Removal of Surgicel® FibrillarTM is advised after hemostasis has been achieved to avoid the development of complications due to a mass effect 2C”
InfluentialSaha, S. P., Muluk, S. C., Schenk, W. G., Dennis, J. W., Ploder, B., Grigorian, A., Presch, I., & Goppelt, A. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2012.01.009 · Cited by 58
Oxidized (non)-regenerated cellulose affects fundamental cellular processes of wound healing
Wagenhäuser, M. U., Mulorz, J. U., Ibing, W., Simon, F., Spin, J. M., Schelzig, H., & Oberhuber, A. (2016) · Scientific Reports · doi:10.1038/srep32238 · Cited by 51
Economic and outcomes consequences of TachoSil®: a systematic review
Colombo, G. L., Bettoni, D., Matteo, S. D., Grumi, C., Molon, C., Spinelli, D., Tarozzo, A., Bruno, G., & Mauro, G. (2014) · Vascular Health and Risk Management · doi:10.2147/vhrm.s63199 · Cited by 45
Simo, K. A., Hanna, E. M., Imagawa, D. K., & Iannitti, D. A. (2012) · ISRN Surgery · doi:10.5402/2012/729086 · Cited by 42 · cited 3×
“TachoSil® has also been employed as reinforcement for the sutured anastomosis of the portal vein and has been shown to be useful in the repair of hepatic artery pseudoaneurism [15].”
BackgroundInfluentialEffect of TachoSil Patch in Prevention of Postoperative Pancreatic Fistula
Marangos, I. P., Røsok, B. I., Kazaryan, A. М., Rosseland, A. R., & Edwin, B. (2011) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-011-1584-9 · Cited by 40
External coating of colonic anastomoses: a systematic review
Pommergaard, H., Achiam, M. P., & Rosenberg, J. (2012) · International Journal of Colorectal Disease · doi:10.1007/s00384-012-1547-y · Cited by 35
Menovsky, T., Ridder, D. J. M. K. D., & Grotenhuis, J. A. (2011) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-0030-1270517 · Cited by 18
Cited by
Polymeric hydrogel systems as emerging biomaterial platforms to enable hemostasis and wound healing
Pourshahrestani, S., Zeimaran, E., Kadri, N. A., Mutlu, N., & Boccaccini, A. R. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000905 · Cited by 448
2021 ELSO Adult and Pediatric Anticoagulation Guidelines
McMichael, A. B. V., Ryerson, L. M., Ratano, D., Fan, E., Faraoni, D., & Annich, G. M. (2022) · ASAIO Journal · doi:10.1097/mat.0000000000001652 · Cited by 437
Chitosan Hemostatic Dressings: Properties and Surgical Applications
Cassano, R., Perri, P., Scarcello, E., Piro, P., Sole, R., Curcio, F., & Trombino, S. (2024) · Polymers · doi:10.3390/polym16131770 · Cited by 77
Metadata
- Authors
- Chiara, O., Cimbanassi, S., Bellanova, G., Chiarugi, M., Mingoli, A., Olivero, G., Ribaldi, S., Tugnoli, G., Basilicò, S., Bindi, F., Briani, L., Renzi, F., Chirletti, P., Di Grezia, G., Martino, A., Marzaioli, R., Noschese, G., Portolani, N., Ruscelli, P., Zago, M., Sgardello, S., Stagnitti, F., & Miniello, S.
- Venue
- BMC Surgery
- Published
- 2018-08-29
- Volume
- 18
- Issue
- 1
- Pages
- 68-68
- ISSN
- 1471-2482 (ISSN-L)
- OpenAlex
- W2889122693
- Cited by
- 158
- References
- 41
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.