Q-Score: development of a new metric for continuous glucose monitoring that enables stratification of antihyperglycaemic therapies
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous glucose monitoring (CGM) has revolutionised diabetes management. CGM enables complete visualisation of the glucose profile, and the uncovering of metabolic 'weak points'. A standardised procedure to evaluate the complex data acquired by CGM, and to create patient-tailored recommendations has not yet been developed. We aimed to develop a new patient-tailored approach for the routine clinical evaluation of CGM profiles. We developed a metric allowing screening for profiles that require therapeutic action and a method to identify the individual CGM parameters with improvement potential. METHODS: Fifteen parameters frequently used to assess CGM profiles were calculated for 1,562 historic CGM profiles from subjects with type 1 or type 2 diabetes. Factor analysis and varimax rotation was performed to identify factors that accounted for the quality of the profiles. RESULTS: We identified five primary factors that determined CGM profiles (central tendency, hyperglycaemia, hypoglycaemia, intra- and inter-daily variations). One parameter from each factor was selected for constructing the formula for the screening metric, (the 'Q-Score'). To derive Q-Score classifications, three diabetes specialists independently categorised 766 CGM profiles into groups of 'very good', 'good', 'satisfactory', 'fair', and 'poor' metabolic control. The Q-Score was then calculated for all profiles, and limits were defined based on the categorised groups (<4.0, very good; 4.0-5.9, good; 6.0-8.4, satisfactory; 8.5-11.9, fair; and ≥12.0, poor). Q-Scores increased significantly (P <0.01) with increasing antihyperglycaemic therapy complexity. Accordingly, the percentage of fair and poor profiles was higher in insulin-treated compared with diet-treated subjects (58.4% vs. 9.3%). In total, 90% of profiles categorised as fair or poor had at least three parameters that could potentially be optimised. The improvement potential of those parameters can be categorised as 'low', 'moderate' and 'high'. CONCLUSIONS: The Q-Score is a new metric suitable to screen for CGM profiles that require therapeutic action. Moreover, because single components of the Q-Score formula respond to individual weak points in glycaemic control, parameters with improvement potential can be identified and used as targets for optimising patient-tailored therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inzucchi, S. E., Bergenstal, R. M., Buse, J. B., Diamant, M., Ferrannini, E., Nauck, M., Peters, A. L., Tsapas, A., Wender, R., & Matthews, D. R. (2012) · Diabetologia · doi:10.1007/s00125-012-2534-0 · Cited by 3,919 · cited 1×
“Patient-tailored diabetes therapy represents the state-of the art in diabetes care and management [38,39].”
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307 · cited 5×
“We performed the first published factor analysis [29,30] of CGM-variables [4-7,9,10].”
Influential
Cited by
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
The relationship of hemoglobin A1C to time-in-range in patients with diabetes
Vigersky, R. A., & McMahon, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0310 · Cited by 464
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Glucose Variability: A Review of Clinical Applications and Research Developments
Rodbard, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0092 · Cited by 154
Metadata
- Authors
- Augstein, P., Heinke, P., Vogt, L., Vogt, R., Rackow, C., Kohnert, K.-D., & Salzsieder, E.
- Venue
- BMC Endocrine Disorders
- Published
- 2015-05-01
- Volume
- 15
- Issue
- 1
- Pages
- 22-22
- ISSN
- 1472-6823 (ISSN-L)
- OpenAlex
- W2076483288
- Cited by
- 51
- References
- 3
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Q-Score: development of a new metric for continuous glucose monitoring that enables stratification of antihyperglycaemic therapies. https://app.cochat.ai/papers/10.1186/s12902-015-0019-0
- The paper
- Augstein, P., Heinke, P., Vogt, L., Vogt, R., Rackow, C., Kohnert, K.-D., & Salzsieder, E. (2015). Q-Score: development of a new metric for continuous glucose monitoring that enables stratification of antihyperglycaemic therapies. BMC Endocrine Disorders. https://doi.org/10.1186/s12902-015-0019-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.