CoChat

Improving peripheral venous cannula insertion in children: a mixed methods study to develop the DIVA key

Open access
Schults, Jessica A., Kleidon, Tricia M., Gibson, Victoria, Ware, Robert S., Monteagle, Emily, Paterson, Rebecca, Charles, Karina, Keys, Adam, McBride, Craig A., McTaggart, Steven, Lawton, Benjamin, Macfarlane, Fiona, Sells, Chloe, Rickard, Claire M., Ullman, Amanda J. · 2022 · BMC Health Services Research
Cited by 49

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Objective: To develop and validate a difficult intravenous access risk assessment and escalation pathway, to increase first time intravenous insertion success in paediatrics. Methods: Mixed methods underpinned by literature and co-production principles. Iterative development of the instrument was informed through semi-structured interviews and stakeholder workshops. The instrument includes a risk assessment, inserter skill self-assessment, and escalation pathways. Reproducibility, reliability, and acceptability were evaluated in a prospective cohort study at a quaternary paediatric hospital in Australia. Results: Interview data (three parents, nine clinicians) uncovered two themes: i) Recognition of children with DIVA and subsequent escalation is ad hoc and problematic; and ii) Resources and training impact inserter confidence and ability. Three workshops were delivered at monthly intervals (February–April 2020) involving 21 stakeholders culminating in the co-production of the “DIVA Key”. The DIVA Key was evaluated between May–December 2020 in 78 children; 156 clinicians. Seventy-eight paired assessments were undertaken with substantial agreement (concordance range = 81.5 to 83.0%) between the assessors. Interrater reliability of the DIVA risk assessment was moderate (kappa = 0.71, 95% CI 0.63–0.80). The DIVA Key predicted multiple insertion attempts for red (high risk) DIVA classification (relative risk ratio 5.7, 95% CI 1.2–27.1; reference low risk). Consumer and clinician satisfaction with DIVA Key was high (median (IQR) = 10 [8–10]; 8 [8–10 respectively). Conclusion: The DIVA Key is a straightforward, reliable instrument with inbuilt escalation pathway to support the identification of children with difficult intravenous access.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12913-022-07605-2

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 49

Metadata

Authors
Schults, J. A., Kleidon, T. M., Gibson, V., Ware, R. S., Monteagle, E., Paterson, R., Charles, K., Keys, A., McBride, C. A., McTaggart, S., Lawton, B., Macfarlane, F., Sells, C., Rickard, C. M., & Ullman, A. J.
Venue
BMC Health Services Research
Published
2022-02-17
Volume
22
Issue
1
Pages
220-220
ISSN
1472-6963 (ISSN-L)
OpenAlex
W4212849499
Cited by
49
References
16
FWCI
11.92
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving peripheral venous cannula insertion in children: a mixed methods study to develop the DIVA key. https://app.cochat.ai/papers/10.1186/s12913-022-07605-2
The paper
Schults, J. A., Kleidon, T. M., Gibson, V., Ware, R. S., Monteagle, E., Paterson, R., Charles, K., Keys, A., McBride, C. A., McTaggart, S., Lawton, B., Macfarlane, F., Sells, C., Rickard, C. M., & Ullman, A. J. (2022). Improving peripheral venous cannula insertion in children: a mixed methods study to develop the DIVA key. BMC Health Services Research. https://doi.org/10.1186/s12913-022-07605-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.