CoChat

Bioprocess automation on a Mini Pilot Plant enables fast quantitative microbial phenotyping

Open access
Unthan, Simon, Radek, Andreas, Wiechert, Wolfgang, Oldiges, Marco, Noack, Stephan · 2015 · Microbial Cell Factories
Cited by 82

The DOI matches its Crossref record.

Abstract

BACKGROUND: The throughput of cultivation experiments in bioprocess development has drastically increased in recent years due to the availability of sophisticated microliter scale cultivation devices. However, as these devices still require time-consuming manual work, the bottleneck was merely shifted to media preparation, inoculation and finally the analyses of cultivation samples. A first step towards solving these issues was undertaken in our former study by embedding a BioLector in a robotic workstation. This workstation already allowed for the optimization of heterologous protein production processes, but remained limited when aiming for the characterization of small molecule producer strains. In this work, we extended our workstation to a versatile Mini Pilot Plant (MPP) by integrating further robotic workflows and microtiter plate assays that now enable a fast and accurate phenotyping of a broad range of microbial production hosts. RESULTS: A fully automated harvest procedure was established, which repeatedly samples up to 48 wells from BioLector cultivations in response to individually defined trigger conditions. The samples are automatically clarified by centrifugation and finally frozen for subsequent analyses. Sensitive metabolite assays in 384-well plate scale were integrated on the MPP for the direct determination of substrate uptake (specifically D-glucose and D-xylose) and product formation (specifically amino acids). In a first application, we characterized a set of Corynebacterium glutamicum L-lysine producer strains and could rapidly identify a unique strain showing increased L-lysine titers, which was subsequently confirmed in lab-scale bioreactor experiments. In a second study, we analyzed the substrate uptake kinetics of a previously constructed D-xylose-converting C. glutamicum strain during cultivation on mixed carbon sources in a fully automated experiment. CONCLUSIONS: The presented MPP is designed to face the challenges typically encountered during early-stage bioprocess development. Especially the bottleneck of sample analyses from fast and parallelized microtiter plate cultivations can be solved using cutting-edge robotic automation. As robotic workstations become increasingly attractive for biotechnological research, we expect our setup to become a template for future bioprocess development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12934-015-0216-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 82

Metadata

Authors
Unthan, S., Radek, A., Wiechert, W., Oldiges, M., & Noack, S.
Venue
Microbial Cell Factories
Published
2015-03-11
Volume
14
Issue
1
Pages
32-32
ISSN
1475-2859 (ISSN-L)
OpenAlex
W2172237924
Cited by
82
References
0
FWCI
4.50
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioprocess automation on a Mini Pilot Plant enables fast quantitative microbial phenotyping. https://app.cochat.ai/papers/10.1186/s12934-015-0216-6
The paper
Unthan, S., Radek, A., Wiechert, W., Oldiges, M., & Noack, S. (2015). Bioprocess automation on a Mini Pilot Plant enables fast quantitative microbial phenotyping. Microbial Cell Factories. https://doi.org/10.1186/s12934-015-0216-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.