CoChat

Preparation of antibacterial and osteoconductive 3D-printed PLGA/Cu(I)@ZIF-8 nanocomposite scaffolds for infected bone repair

Open access
Zou, Fei, Jiang, Jianyuan, Lv, Feizhou, Xia, Xinlei, Ma, Xiaosheng · 2020 · Journal of Nanobiotechnology
Cited by 115

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The repair of large bone defects is a great challenge in clinical practice. In this study, copper-loaded-ZIF-8 nanoparticles and poly (lactide-co-glycolide) (PLGA) were combined to fabricate porous PLGA/Cu(I)@ZIF-8 scaffolds using three-dimensional printing technology for infected bone repair. Methods: The surface morphology of PLGA/Cu(I)@ZIF-8 scaffolds was investigated by transmission electron microscopy and scanning electron microscopy. The PLGA/Cu(I)@ZIF-8 scaffolds were co-cultured with bacteria to determine their antibacterial properties, and with murine mesenchymal stem cells (MSCs) to explore their biocompatibility and osteoconductive properties. The bioactivity of the PLGA/Cu(I)@ZIF-8 scaffolds was evaluated by incubating in simulated body fluid. Results: The results revealed that the PLGA/Cu(I)@ZIF-8 scaffolds had porosities of 80.04 ± 5.6% and exhibited good mechanical properties. When incubated with H 2 O 2, Cu(I)@ZIF-8 nanoparticles resulted generated reactive oxygen species, which contributed to their antibacterial properties. The mMSCs cultured on the surface of PLGA/Cu(I)@ZIF-8 scaffolds were well-spread and adherent with a high proliferation rate, and staining with alkaline phosphatase and alizarin red was increased compared with the pure PLGA scaffolds. The mineralization assay showed an apatite-rich layer was formed on the surface of PLGA/Cu(I)@ZIF-8 scaffolds, while there was hardly any apatite on the surface of the PLGA scaffolds. Additionally, in vitro, Staphylococcus aureus cultured on the PLGA/Cu(I)@ZIF-8 scaffolds were almost all dead, while in vivo inflammatory cell infiltration and bacteria numbers were dramatically reduced in infected rats implanted with PLGA/Cu@ZIF-8 scaffolds. Conclusion: All these findings demonstrate that PLGA/Cu(I)@ZIF-8 scaffolds possess excellent antibacterial and osteoconductive properties, as well as good biocompatibility and high bioactivity. This study suggests that the PLGA/Cu(I)@ZIF-8 scaffolds could be used as a promising biomaterial for bone tissue engineering, especially for infected bone repair.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12951-020-00594-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 115

Metadata

Authors
Zou, F., Jiang, J., Lv, F., Xia, X., & Ma, X.
Venue
Journal of Nanobiotechnology
Published
2020-02-27
Volume
18
Issue
1
Pages
39-39
ISSN
1477-3155 (ISSN-L)
OpenAlex
W3011499104
Cited by
115
References
2
FWCI
4.87
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preparation of antibacterial and osteoconductive 3D-printed PLGA/Cu(I)@ZIF-8 nanocomposite scaffolds for infected bone repair. https://app.cochat.ai/papers/10.1186/s12951-020-00594-6
The paper
Zou, F., Jiang, J., Lv, F., Xia, X., & Ma, X. (2020). Preparation of antibacterial and osteoconductive 3D-printed PLGA/Cu(I)@ZIF-8 nanocomposite scaffolds for infected bone repair. Journal of Nanobiotechnology. https://doi.org/10.1186/s12951-020-00594-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.