Quantification of left atrial strain and strain rate using Cardiovascular Magnetic Resonance myocardial feature tracking: a feasibility study
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cardiovascular Magnetic Resonance myocardial feature tracking (CMR-FT) is a quantitative technique tracking tissue voxel motion on standard steady-state free precession (SSFP) cine images to assess ventricular myocardial deformation. The importance of left atrial (LA) deformation assessment is increasingly recognized and can be assessed with echocardiographic speckle tracking. However atrial deformation quantification has never previously been demonstrated with CMR. We sought to determine the feasibility and reproducibility of CMR-FT for quantitative derivation of LA strain and strain rate (SR) myocardial mechanics. METHODS: 10 healthy volunteers, 10 patients with hypertrophic cardiomyopathy (HCM) and 10 patients with heart failure and preserved ejection fraction (HFpEF) were studied at 1.5 Tesla. LA longitudinal strain and SR parameters were derived from SSFP cine images using dedicated CMR-FT software (2D CPA MR, TomTec, Germany). LA performance was analyzed using 4- and 2-chamber views including LA reservoir function (total strain [εs], peak positive SR [SRs]), LA conduit function (passive strain [εe], peak early negative SR [SRe]) and LA booster pump function (active strain [εa], late peak negative SR [SRa]). RESULTS: In all subjects LA strain and SR parameters could be derived from SSFP images. There was impaired LA reservoir function in HCM and HFpEF (εs [%]: HCM 22.1 ± 5.5, HFpEF 16.3 ± 5.8, Controls 29.1 ± 5.3, p < 0.01; SRs [s⁻¹]: HCM 0.9 ± 0.2, HFpEF 0.8 ± 0.3, Controls 1.1 ± 0.2, p < 0.05) and impaired LA conduit function as compared to healthy controls (εe [%]: HCM 10.4 ± 3.9, HFpEF 11.9 ± 4.0, Controls 21.3 ± 5.1, p < 0.001; SRe [s]⁻¹: HCM -0.5 ± 0.2, HFpEF -0.6 ± 0.1, Controls -1.0 ± 0.3, p < 0.01). LA booster pump function was increased in HCM while decreased in HFpEF (εa [%]: HCM 11.7 ± 4.0, HFpEF 4.5 ± 2.9, Controls 7.8 ± 2.5, p < 0.01; SRa [s⁻¹]: HCM -1.2 ± 0.4, HFpEF -0.5 ± 0.2, Controls -0.9 ± 0.3, p < 0.01). Observer variability was excellent for all strain and SR parameters on an intra- and inter-observer level as determined by Bland-Altman, coefficient of variation and intraclass correlation coefficient analyses. CONCLUSIONS: CMR-FT based atrial performance analysis reliably quantifies LA longitudinal strain and SR from standard SSFP cine images and discriminates between patients with impaired left ventricular relaxation and healthy controls. CMR-FT derived atrial deformation quantification seems a promising novel approach for the study of atrial performance and physiology in health and disease states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Antlanger, M., Aschauer, S., Kopecky, C., Hecking, M., Kovarik, J. J., Werzowa, J., Mascherbauer, J., Genser, B., Säemann, M. D., & Bonderman, D. (2017) · Kidney and Blood Pressure Research · doi:10.1159/000473868 · Cited by 2,808
Paulus, W. J., Tschöpe, C., Sanderson, J. E., Rusconi, C., Flachskampf, F. A., Rademakers, F. E., Marino, P., Smiseth, O. A., De Keulenaer, G., Leite-Moreira, A. F., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm037 · Cited by 2,679
Grothues, F., Smith, G. C., Moon, J. C. C., Bellenger, N. G., Collins, P., Klein, H. U., & Pennell, D. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02381-0 · Cited by 1,267
Mor-Avi, V., Lang, R. M., Badano, L. P., Belohlavek, M., Cardim, N. M., Derumeaux, G., Galderisi, M., Marwick, T., Nagueh, S. F., Sengupta, P. P., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.01.015 · Cited by 1,254
Hoit, B. D. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.055 · Cited by 980
Left Atrial Function in Diastolic Heart Failure
Kurt, M., Wang, J., Torre-Amione, G., & Nagueh, S. F. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.813071 · Cited by 502
Cameli, M., Caputo, M., Mondillo, S., Ballo, P., Palmerini, E., Lisi, M., Marino, E., & Galderisi, M. (2009) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-7-6 · Cited by 389
Hor, K. N., Gottliebson, W. M., Carson, C., Wash, E., Cnota, J., Fleck, R., Wansapura, J., Klimeczek, P., Al-Khalidi, H. R., Chung, E. S., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.006 · Cited by 379
Vianna-Pinton, R., Moreno, C. A., Baxter, C. M., Lee, K. S., Tsang, T. S. M., & Appleton, C. P. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.12.017 · Cited by 338
Clinical Utility of Multimodality LA Imaging
To, A. C. Y., Flamm, S. D., Marwick, T. H., & Klein, A. L. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.02.018 · Cited by 236
Schuster, A., Kutty, S., Padiyath, A., Parish, V., Gribben, P., Danford, D. A., Makowski, M. R., Bigalke, B., Beerbaum, P., & Nagel, E. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-58 · Cited by 158
Self-citationMorris, D. A., Gailani, M., Pérez, A. V., Blaschke, F., Dietz, R., Haverkamp, W., & Özcelik, C. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.02.004 · Cited by 156
Järvinen, V. M., Kupari, M. M., Hekali, P. E., & Poutanen, V.-P. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90298-4 · Cited by 130
Sievers, B., Kirchberg, S., Addo, M., Bakan, A., Brandts, B., & TRAPPE, H. J. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200036170 · Cited by 129
Schuster, A., Paul, M., Bettencourt, N., Morton, G., Chiribiri, A., Ishida, M., Hussain, S. T., Jogiya, R., Kutty, S., Bigalke, B., et al. (2011) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.10.137 · Cited by 125
Self-citationD’Andrea, A., Corato, G. D., Scarafile, R., Romano, S., Reigler, L., Mita, C., Allocca, F., Limongelli, G., Gigantino, G., Liccardo, B., et al. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.041210 · Cited by 89
Padiyath, A., Gribben, P., Abraham, J. R., Li, L., Rangamani, S., Schuster, A., Danford, D. A., Pedrizzetti, G., & Kutty, S. (2012) · Echocardiography · doi:10.1111/echo.12016 · Cited by 82
Self-citationSingh, A., Steadman, C. D., Khan, J. N., Horsfield, M. A., Bekele, S., Nazir, S. A., Kanagala, P., Masca, N. G. D., Clarysse, P., & McCann, G. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24625 · Cited by 76
Kaminski, M. A., Steel, K. E., Jerosch‐Herold, M., Khin, M. M., Tsang, S. W., Hauser, T. H., & Kwong, R. Y. K. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-42 · Cited by 76
Murata, M., Iwanaga, S., Tamura, Y., Kondo, M., Kouyama, K., Murata, M., & Ogawa, S. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.05.067 · Cited by 73
Onishi, T., Saha, S. K., Ludwig, D. R., Onishi, T., Marek, J. J., Cavalcante, J. L., Schelbert, E. B., SCHWARTZMAN, D. S., & Gorcsan, J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-95 · Cited by 72
Kutty, S., Padiyath, A., Li, L., Peng, Q., Rangamani, S., Schuster, A., & Danford, D. A. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.12.016 · Cited by 70
Self-citationRing, L. S., Rana, B. S., Wells, F. C., Kydd, A. C., & Dutka, D. P. (2014) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2013.12.009 · Cited by 49
Anwar, A. M., Soliman, O. I. I., Geleijnse, M. L., Michels, M., Vletter, W. B., Nemes, A., & ten Cate, F. J. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.11.017 · Cited by 40
Cited by
Tissue Tracking Technology for Assessing Cardiac Mechanics
Claus, P., Omar, A. M. S., Pedrizzetti, G., Sengupta, P. P., & Nagel, E. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.11.001 · Cited by 439
Strain imaging using cardiac magnetic resonance
Scatteia, A., Baritussio, A., & Bucciarelli-Ducci, C. (2017) · Heart Failure Reviews · doi:10.1007/s10741-017-9621-8 · Cited by 366
Smiseth, O. A., Rider, O., Cvijic, M., Valkovič, L., Remme, E. W., & Voigt, J.-U. (2025) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2024.07.011 · Cited by 231
Patient selection in heart failure with preserved ejection fraction clinical trials
Kelly, J. P., Mentz, R. J., Mebazaa, A., Voors, A. A., Butler, J., Roessig, L., Fiuzat, M., Zannad, F., Pitt, B., O’Connor, C. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.043 · Cited by 139
Metadata
- Authors
- Kowallick, J. T., Kutty, S., Edelmann, F., Chiribiri, A., Villa, A., Steinmetz, M., Sohns, J. M., Staab, W., Bettencourt, N., Unterberg-Buchwald, C., Hasenfuß, G., Lotz, J., & Schuster, A.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 16
- Issue
- 1
- Pages
- 60
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2134517026
- Cited by
- 264
- References
- 26
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.