Quantification of LV function and mass by cardiovascular magnetic resonance: multi-center variability and consensus contours
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: High reproducibility of LV mass and volume measurement from cine cardiovascular magnetic resonance (CMR) has been shown within single centers. However, the extent to which contours may vary from center to center, due to different training protocols, is unknown. We aimed to quantify sources of variation between many centers, and provide a multi-center consensus ground truth dataset for benchmarking automated processing tools and facilitating training for new readers in CMR analysis. METHODS: Seven independent expert readers, representing seven experienced CMR core laboratories, analyzed fifteen cine CMR data sets in accordance with their standard operating protocols and SCMR guidelines. Consensus contours were generated for each image according to a statistical optimization scheme that maximized contour placement agreement between readers. RESULTS: Reader-consensus agreement was better than inter-reader agreement (end-diastolic volume 14.7 ml vs 15.2-28.4 ml; end-systolic volume 13.2 ml vs 14.0-21.5 ml; LV mass 17.5 g vs 20.2-34.5 g; ejection fraction 4.2 % vs 4.6-7.5 %). Compared with consensus contours, readers were very consistent (small variability across cases within each reader), but bias varied between readers due to differences in contouring protocols at each center. Although larger contour differences were found at the apex and base, the main effect on volume was due to small but consistent differences in the position of the contours in all regions of the LV. CONCLUSIONS: A multi-center consensus dataset was established for the purposes of benchmarking and training. Achieving consensus on contour drawing protocol between centers before analysis, or bias correction after analysis, is required when collating multi-center results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 1×
“Consensus contour estimation Consensus contours were estimated using the Simultaneous Truth and Performance Level Estimation (STAPLE) method [12].”
MethodMedrano-Gracia, P., Cowan, B. R., Ambale-Venkatesh, B., Bluemke, D. A., Eng, J., Finn, J. P., Fonseca, C. G., Lima, J. A., Suinesiaputra, A., & Young, A. A. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0056-2 · Cited by 98 · cited 1×
“Although there are several recourses that offer large breadth [5, 9, 10], no resource offers depth of expert analysis from multiple centers.”
BackgroundSelf-citation
Cited by
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Self-citationTao, Q., Yan, W., Wang, Y., Paiman, E. H. M., Shamonin, D. P., Garg, P., Plein, S., Huang, L., Xia, L., Sramko, M., et al. (2019) · Radiology · doi:10.1148/radiol.2018180513 · Cited by 209
“he inal average perpendicular distance of approximately 1 mm was comparable to the intra- and interobserver variability (7,18,19) and largely surpassed previous machine learning methods (approximately 2 mm) (8–10).”
BackgroundSelf-citationLeft-Ventricle Quantification Using Residual U-Net
Kerfoot, E., Clough, J., Oksuz, I., Lee, J., King, A. P., & Schnabel, J. A. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-12029-0_40 · Cited by 205
3-D Consistent and Robust Segmentation of Cardiac Images by Deep Learning With Spatial Propagation
Zheng, Q., Delingette, H., Duchateau, N., & Ayache, N. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2820742 · Cited by 202
Assessment of mitral valve regurgitation by cardiovascular magnetic resonance imaging
Garg, P., Swift, A. J., Zhong, L., Carlhäll, C.-J., Ebbers, T., Westenberg, J., Hope, M. D., Bucciarelli-Ducci, C., Bax, J. J., & Myerson, S. G. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0305-z · Cited by 183
Self-citation
Metadata
- Authors
- Suinesiaputra, A., Bluemke, D. A., Cowan, B. R., Friedrich, M. G., Kramer, C. M., Kwong, R., Plein, S., Schulz-Menger, J., Westenberg, J. J. M., Young, A. A., & Nagel, E.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 17
- Issue
- 1
- Pages
- 63
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W1820889844
- Cited by
- 186
- References
- 3
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of LV function and mass by cardiovascular magnetic resonance: multi-center variability and consensus contours. https://app.cochat.ai/papers/10.1186/s12968-015-0170-9
- The paper
- Suinesiaputra, A., Bluemke, D. A., Cowan, B. R., Friedrich, M. G., Kramer, C. M., Kwong, R., Plein, S., Schulz-Menger, J., Westenberg, J. J. M., Young, A. A., & Nagel, E. (2015). Quantification of LV function and mass by cardiovascular magnetic resonance: multi-center variability and consensus contours. Journal of Cardiovascular Magnetic Resonance. https://doi.org/10.1186/s12968-015-0170-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.