Quantification of LV function and mass by cardiovascular magnetic resonance: multi-center variability and consensus contours
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: High reproducibility of LV mass and volume measurement from cine cardiovascular magnetic resonance (CMR) has been shown within single centers. However, the extent to which contours may vary from center to center, due to different training protocols, is unknown. We aimed to quantify sources of variation between many centers, and provide a multi-center consensus ground truth dataset for benchmarking automated processing tools and facilitating training for new readers in CMR analysis. METHODS: Seven independent expert readers, representing seven experienced CMR core laboratories, analyzed fifteen cine CMR data sets in accordance with their standard operating protocols and SCMR guidelines. Consensus contours were generated for each image according to a statistical optimization scheme that maximized contour placement agreement between readers. RESULTS: Reader-consensus agreement was better than inter-reader agreement (end-diastolic volume 14.7 ml vs 15.2-28.4 ml; end-systolic volume 13.2 ml vs 14.0-21.5 ml; LV mass 17.5 g vs 20.2-34.5 g; ejection fraction 4.2 % vs 4.6-7.5 %). Compared with consensus contours, readers were very consistent (small variability across cases within each reader), but bias varied between readers due to differences in contouring protocols at each center. Although larger contour differences were found at the apex and base, the main effect on volume was due to small but consistent differences in the position of the contours in all regions of the LV. CONCLUSIONS: A multi-center consensus dataset was established for the purposes of benchmarking and training. Achieving consensus on contour drawing protocol between centers before analysis, or bias correction after analysis, is required when collating multi-center results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444 · cited 1×
“The STAPLE method uses Expectation-Maximization [13] to calculate the optimal consensus contour, as well as the reader sensitivity and specificity.”
MethodMulti-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942 · cited 1×
“Because of these advantages, CMR is becoming widely used for the measurement of ventricular volumes, function and mass in many clinical centers, as well as in large research studies including the Multi-Ethnic Study of Atherosclerosis (MESA) [4] and the UK Biobank [5].”
BackgroundWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 1×
“Consensus contour estimation Consensus contours were estimated using the Simultaneous Truth and Performance Level Estimation (STAPLE) method [12].”
MethodSchulz-Menger, J., Bluemke, D. A., Bremerich, J., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Kim, R. J., von Knobelsdorff-Brenkenhoff, F., Kramer, C. M., Pennell, D. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-35 · Cited by 2,097 · cited 4×
“that the outflow tract was contoured as part of the LV cavity as recommended in the SCMR guidelines [11].”
MethodSelf-citationGrothues, F., Smith, G. C., Moon, J. C. C., Bellenger, N. G., Collins, P., Klein, H. U., & Pennell, D. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02381-0 · Cited by 1,267
The Relationship of Left Ventricular Mass and Geometry to Incident Cardiovascular Events
Bluemke, D. A., Kronmal, R. A., Lima, J. A. C., Liu, K., Olson, J., Burke, G. L., & Folsom, A. R. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.09.014 · Cited by 808 · cited 1×
“In particular, LV mass (LVM) is an independent predictor of cardiovascular events [1], and end-diastolic volume (EDV) and end-systolic volume (ESV) are associated with adverse remodeling [2].”
BackgroundSelf-citationBOTTINI, P., CARR, A., PRISANT, L., FLICKINGER, F., ALLISON, J., & GOTTDIENER, J. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00178-e · Cited by 363 · cited 1×
“High reproducibility of LV mass and volume measurement based on cine CMR has been shown within single centers [7, 8], but differences in training and standard operating procedures may occur between centers [6].”
BackgroundFonseca, C. G., Backhaus, M., Bluemke, D. A., Britten, R. D., Chung, J. D., Cowan, B. R., Dinov, I. D., Finn, J. P., Hunter, P. J., Kadish, A. H., et al. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr360 · Cited by 280 · cited 1×
“Although resources are becoming available with many hundreds and even thousands of studies [5, 17], these provide manual contours from a small number (typically one or two) of centers.”
BackgroundSelf-citationPetersen, S. E., Matthews, P. M., Bamberg, F., Bluemke, D. A., Francis, J. M., Friedrich, M. G., Leeson, P., Nagel, E., Plein, S., Rademakers, F. E., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-46 · Cited by 266 · cited 3×
“Because of these advantages, CMR is becoming widely used for the measurement of ventricular volumes, function and mass in many clinical centers, as well as in large research studies including the Multi-Ethnic Study of Atherosclerosis (MESA) [4] and the UK Biobank [5].”
BackgroundSelf-citationPapavassiliu, T., Kühl, H. P., Schröder, M., Süselbeck, T., Bondarenko, O., Böhm, C. K., Beek, A., Hofman, M. M. B., & van Rossum, A. C. (2005) · Radiology · doi:10.1148/radiol.2353040601 · Cited by 215 · cited 1×
“The formation of a manual ground truth from many expert readers would be very time consuming, but very valuable for validating automated methods [18, 19].”
Method
Cited by
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Self-citationTao, Q., Yan, W., Wang, Y., Paiman, E. H. M., Shamonin, D. P., Garg, P., Plein, S., Huang, L., Xia, L., Sramko, M., et al. (2019) · Radiology · doi:10.1148/radiol.2018180513 · Cited by 209
“he inal average perpendicular distance of approximately 1 mm was comparable to the intra- and interobserver variability (7,18,19) and largely surpassed previous machine learning methods (approximately 2 mm) (8–10).”
BackgroundSelf-citationLeft-Ventricle Quantification Using Residual U-Net
Kerfoot, E., Clough, J., Oksuz, I., Lee, J., King, A. P., & Schnabel, J. A. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-12029-0_40 · Cited by 205
3-D Consistent and Robust Segmentation of Cardiac Images by Deep Learning With Spatial Propagation
Zheng, Q., Delingette, H., Duchateau, N., & Ayache, N. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2820742 · Cited by 202
Assessment of mitral valve regurgitation by cardiovascular magnetic resonance imaging
Garg, P., Swift, A. J., Zhong, L., Carlhäll, C.-J., Ebbers, T., Westenberg, J., Hope, M. D., Bucciarelli-Ducci, C., Bax, J. J., & Myerson, S. G. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0305-z · Cited by 183
Self-citationJabbar, A., Ingoe, L., Junejo, S., Carey, P., Addison, C., Thomas, H., Parikh, J. D., Austin, D., Hollingsworth, K. G., Stocken, D. D., et al. (2020) · JAMA · doi:10.1001/jama.2020.9389 · Cited by 64
Metadata
- Authors
- Suinesiaputra, A., Bluemke, D. A., Cowan, B. R., Friedrich, M. G., Kramer, C. M., Kwong, R., Plein, S., Schulz-Menger, J., Westenberg, J. J. M., Young, A. A., & Nagel, E.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 17
- Issue
- 1
- Pages
- 63
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W1820889844
- Cited by
- 186
- References
- 18
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.