CoChat

Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium

Open access
Micó-Amigo, M. Encarna, Bonci, Tecla, Paraschiv-Ionescu, Anisoara, Ullrich, Martin, Kirk, Cameron, Soltani, Abolfazl, Küderle, Arne, Gazit, Eran, Salis, Francesca, Alcock, Lisa, Aminian, Kamiar, Becker, Clemens, Bertuletti, Stefano, Brown, Philip, Buckley, Ellen, Cantu, Alma, Carsin, Anne-Elie, Caruso, Marco, Caulfield, Brian, Cereatti, Andrea, Chiari, Lorenzo, D’Ascanio, Ilaria, Eskofier, Bjoern, Fernstad, Sara, Froehlich, Marcel, Garcia-Aymerich, Judith, Hansen, Clint, Hausdorff, Jeffrey M., Hiden, Hugo, Hume, Emily, Keogh, Alison, Kluge, Felix, Koch, Sarah, Maetzler, Walter, Megaritis, Dimitrios, Mueller, Arne, Niessen, Martijn, Palmerini, Luca, Schwickert, Lars, Scott, Kirsty, Sharrack, Basil, Sillén, Henrik, Singleton, David, Vereijken, Beatrix, Vogiatzis, Ioannis, Yarnall, Alison J., Rochester, Lynn, Mazzà, Claudia, Del Din, Silvia, for the Mobilise-D consortium · 2023 · Journal of NeuroEngineering and Rehabilitation
Cited by 144

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. Methods: Twenty healthy older adults, 20 people with Parkinson’s disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. Results: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms’ performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. Conclusions: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms’ performances. Trial registration ISRCTN – 12246987.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12984-023-01198-5

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 144

Metadata

Authors
Micó-Amigo, M. E., Bonci, T., Paraschiv-Ionescu, A., Ullrich, M., Kirk, C., Soltani, A., Küderle, A., Gazit, E., Salis, F., Alcock, L., Aminian, K., Becker, C., Bertuletti, S., Brown, P., Buckley, E., Cantu, A., Carsin, A.-E., Caruso, M., Caulfield, B., Cereatti, A., Chiari, L., D’Ascanio, I., Eskofier, B., Fernstad, S., Froehlich, M., Garcia-Aymerich, J., Hansen, C., Hausdorff, J. M., Hiden, H., Hume, E., Keogh, A., Kluge, F., Koch, S., Maetzler, W., Megaritis, D., Mueller, A., Niessen, M., Palmerini, L., Schwickert, L., Scott, K., Sharrack, B., Sillén, H., Singleton, D., Vereijken, B., Vogiatzis, I., Yarnall, A. J., Rochester, L., Mazzà, C., Del Din, S., & for the Mobilise-D consortium
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2023-06-14
Volume
20
Issue
1
Pages
78-78
ISSN
1743-0003 (ISSN-L)
OpenAlex
W4380684948
Cited by
144
References
6
FWCI
13.09
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium. https://app.cochat.ai/papers/10.1186/s12984-023-01198-5
The paper
Micó-Amigo, M. E., Bonci, T., Paraschiv-Ionescu, A., Ullrich, M., Kirk, C., Soltani, A., Küderle, A., Gazit, E., Salis, F., Alcock, L., Aminian, K., Becker, C., Bertuletti, S., Brown, P., Buckley, E., Cantu, A., Carsin, A.-E., Caruso, M., Caulfield, B., . . . for the Mobilise-D consortium. (2023). Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/s12984-023-01198-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.