CoChat

Monoclonal antibody exposure in rat and cynomolgus monkey cerebrospinal fluid following systemic administration

Open access
Wang, Qin, Delva, Luisette, Weinreb, Paul H., Pepinsky, Robert B., Graham, Danielle, Veizaj, Elvana, Cheung, Anne E., Chen, Weiping, Nestorov, Ivan, Rohde, Ellen, Caputo, Robin, Kuesters, Geoffrey M., Bohnert, Tonika, Gan, Liang-Shang · 2018 · Fluids and Barriers of the CNS
Cited by 72

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Many studies have focused on the challenges of small molecule uptake across the blood–brain barrier, whereas few in-depth studies have assessed the challenges with the uptake of antibodies into the central nervous system (CNS). In drug development, cerebrospinal fluid (CSF) sampling is routinely used as a surrogate for assessing CNS drug exposure and biomarker levels. In this report, we have studied the kinetic correlation between CSF and serum drug concentration–time profiles for five humanized monoclonal antibodies in rats and cynomolgus monkeys and analyzed factors that affect their CSF exposure. Upon intravenous (IV) bolus injection, antibodies entered the CNS slowly and reached maximum CSF concentration ( CSF T max ) in one to several days in both rats and monkeys. Antibody serum and CSF concentration–time curves converged until they became parallel after CSF T max was reached. Antibody half-lives in CSF ( CSF t ½ ) approximated their serum half-lives ( serum t ½ ). Although the intended targets of these antibodies were different, the steady-state CSF to serum concentration ratios were similar at 0.1–0.2% in both species. Independent of antibody target and serum concentration, CSF-to-serum concentration ratios for individual monkeys ranged by up to tenfold from 0.03 to 0.3%. Upon systemic administration, average antibodies CSF-to-serum concentration ratios in rats and monkeys were 0.1–0.2%. The CSF t ½ of the antibodies was largely determined by their long systemic t ½ ( systemic t ½ ).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12987-018-0093-6

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 72

Metadata

Authors
Wang, Q., Delva, L., Weinreb, P. H., Pepinsky, R. B., Graham, D., Veizaj, E., Cheung, A. E., Chen, W., Nestorov, I., Rohde, E., Caputo, R., Kuesters, G. M., Bohnert, T., & Gan, L.-S.
Venue
Fluids and Barriers of the CNS
Published
2018-03-20
Volume
15
Issue
1
Pages
10-10
ISSN
2045-8118 (ISSN-L)
OpenAlex
W2803416469
Cited by
72
References
5
FWCI
2.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.