Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Introduction: Fluid resuscitation is crucial in managing hemodynamically unstable patients. The last decade witnessed the use of pulse pressure variation (PPV) to predict fluid responsiveness. However, as far as we know, no systematic review and meta-analysis has been carried out to evaluate the value of PPV in predicting fluid responsiveness specifically upon patients admitted into intensive care units. Methods: We searched MEDLINE and EMBASE and included clinical trials that evaluated the association between PPV and fluid responsiveness after fluid challenge in mechanically ventilated patients in intensive care units. Data were synthesized using an exact binomial rendition of the bivariate mixed-effects regression model modified for synthesis of diagnostic test data. Result: Twenty-two studies with 807 mechanically ventilated patients with tidal volume more than 8 ml/kg and without spontaneous breathing and cardiac arrhythmia were included, and 465 were responders (58%). The pooled sensitivity was 0.88 (95% confidence interval (CI) 0.81 to 0.92) and pooled specificity was 0.89 (95% CI 0.84 to 0.92). A summary receiver operating characteristic curve yielded an area under the curve of 0.94 (95% CI 0.91 to 0.95). A significant threshold effect was identified. Conclusions: PPV predicts fluid responsiveness accurately in mechanically ventilated patients with relative large tidal volume and without spontaneous breathing and cardiac arrhythmia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · cited 1×
“Moreover, conflicting results have been reported with regards to studies investigating goaldirected hemodynamic therapy in critically ill patients, such as Rivers and colleagues’ study and the OPTIMISE study [5,6].”
ResultWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 1×
“Publication bias was investigated using Deeks’ funnel plot asymmetry test and the P value for the slope coefficient was reported [22].”
MethodMICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Conducting systematic reviews of diagnostic studies: didactic guidelines
Devillé, W. L., Buntinx, F., Bouter, L. M., Montori, V. M., de Vet, H. C., van der Windt, D. A., & Bezemer, P. D. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-9 · Cited by 960
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Pearse, R. M., Harrison, D. A., MacDonald, N., Gillies, M. A., Blunt, M., Ackland, G., Grocott, M. P. W., Ahern, A., Griggs, K., Scott, R., et al. (2014) · JAMA · doi:10.1001/jama.2014.5305 · Cited by 862
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Antonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
The Importance of Fluid Management in Acute Lung Injury Secondary to Septic Shock
Murphy, C. V., Schramm, G. E., Doherty, J. A., Reichley, R. M., Gajic, O., Afessa, B., Micek, S. T., & Kollef, M. H. (2009) · Chest · doi:10.1378/chest.08-2706 · Cited by 441
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424
High Tidal Volume and Positive Fluid Balance Are Associated With Worse Outcome in Acute Lung Injury
Sakr, Y., Vincent, J.-L., Reinhart, K., Groeneveld, J., Michalopoulos, A., Sprung, C. L., Artigas, A., & Ranieri, V. M. (2005) · Chest · doi:10.1378/chest.128.5.3098 · Cited by 405
MICHARD, F., CHEMLA, D., RICHARD, C., WYSOCKI, M., PINSKY, M. R., LECARPENTIER, Y., & TEBOUL, J.-L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805077 · Cited by 371
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
No role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients
Feissel, M., Teboul, J., Merlani, P. G., Badie, J. C., Faller, J.-P., & Bendjelid, K. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0602-6 · Cited by 300
Monnet, X., Bleibtreu, A., Ferré, A., Dres, M., Gharbi, R., Richard, C., & Teboul, J.-L. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31822f08d7 · Cited by 246
Bivariate random-effects meta-analysis and the estimation of between-study correlation
Riley, R. D., Abrams, K. R., Sutton, A. J., Lambert, P. C., & Thompson, J. R. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-3 · Cited by 244
Riley, R. D., Abrams, K. R., Lambert, P. C., Sutton, A. J., & Thompson, J. R. (2007) · Statistics in Medicine · doi:10.1002/sim.2524 · Cited by 199
Pulse Pressure Variation Predicts Fluid Responsiveness Following Coronary Artery Bypass Surgery
Kramer, A., Zygun, D., Hawes, H., Easton, P., & Ferland, A. (2004) · Chest · doi:10.1378/chest.126.5.1563 · Cited by 192
Riley, R. D., Thompson, J. R., & Abrams, K. R. (2008) · Biostatistics · doi:10.1093/biostatistics/kxm023 · Cited by 167
Mahjoub, Y., Lejeune, V., Müller, L., Perbet, S., Zieleskiewicz, L., Bart, F., Veber, B., Paugam‐Burtz, C., Jaber, S., Ayham, A., et al. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet442 · Cited by 163
Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
Wiesenack, C., Fiegl, C., Keyser, A., Prasser, C., & Keyl, C. (2005) · European Journal of Anaesthesiology · doi:10.1017/s0265021505001092 · Cited by 146
Huang, C.-C., Fu, J., Hu, H., Kao, K., Chen, N., Hsieh, M., & Tsai, Y. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186b74e · Cited by 143
Müller, L., Louart, G., Bousquet, P., Candela, D., Zoric, L., Coussaye, J.-E. D. L., Jaber, S., & Lefrant, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1686-y · Cited by 141
Dynamic indices do not predict volume responsiveness in routine clinical practice
Lansdorp, B., Lemson, J., van Putten, M. J. A. M., de Keijzer, A., van der Hoeven, J. G., & Pickkers, P. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer411 · Cited by 141
Monnet, X., Dres, M., Ferré, A., Teuff, G. L., Jozwiak, M., Bleibtreu, A., Deley, M. L., Chemla, D., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes182 · Cited by 132
Online Monitoring of Pulse Pressure Variation to Guide Fluid Therapy After Cardiac Surgery
Júnior, J. O. C. A., Galas, F. R. B. G., Hajjar, L. A., dos Santos, L. O., Carvalho, T. F. G. D. L., & Michard, F. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000287664.03547.c6 · Cited by 127
Lakhal, K., Ehrmann, S., Benzékri-Lefèvre, D., Runge, I., Legras, A., Dequin, P., Mercier, E., Wolff, M., Regnier, B., & Boulain, T. (2011) · Critical Care · doi:10.1186/cc10083 · Cited by 122
Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients
Feissel, M., Badie, J. C., Merlani, P. G., Faller, J.-P., & Bendjelid, K. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000186415.43713.2f · Cited by 108
Monnet, X., Guérin, L., Jozwiak, M., Bataille, A., Fournier, J., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes373 · Cited by 105
Pleth variability index predicts fluid responsiveness in critically ill patients*
Loupec, T., Nanadoumgar, H., Frasca, D., Petitpas, F., Laksiri, L., Baudouin, D., Debaene, B., Dahyot‐Fizelier, C., & Mimoz, O. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181ffde1c · Cited by 104
Techniques for Assessment of Intravascular Volume in Critically Ill Patients
Marik, P. E. (2009) · Journal of Intensive Care Medicine · doi:10.1177/0885066609340640 · Cited by 100
Wyffels, P., Durnez, P., Helderweirt, J., Stockman, W., & Kegel, D. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000267520.16003.17 · Cited by 80
Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness
Vallée, F., Richard, J.-C., Mari, A., Gallas, T., Arsac, E., Sanchez-Verlaan, P., Chousterman, B. G., Samii, K., Genestal, M., & Fourcade, O. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1478-4 · Cited by 73
García, M. I. M., Cano, A. G., & Monrové, J. C. D. (2009) · Critical Care · doi:10.1186/cc8027 · Cited by 73
Prediction of fluid responsiveness in septic shock patients
Khwannimit, B., & Bhurayanontachai, R. (2011) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32834b7d82 · Cited by 66
Fischer, M., Coucoravas, J., TRUONG, J., Zhu, L., Gérard, J., Hanouz, J., & Fellahi, J. L. (2013) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12108 · Cited by 56
Guinot, P., Zogheib, E. H., Detave, M., Moubarak, M., Hubert, V., Badoux, L., Bernard, E., Besserve, P., Caus, T., & Dupont, H. (2011) · Critical Care · doi:10.1186/cc10451 · Cited by 54
Nordström, J., Hällsjö-Sander, C., Shore, R., & Björne, H. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes399 · Cited by 48
Evaluation of stroke volume variations obtained with the pressure recording analytic method*
Biais, M., Cottenceau, V., Stecken, L., Jean, M., Ottolenghi, L., Roullet, S., Quinart, A., & Sztark, F. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31823bc632 · Cited by 38
de Oliveira-Costa, C. D. A., Friedman, G., Vieira, S. R. R., & Fialkow, L. (2012) · Clinics · doi:10.6061/clinics/2012(07)12 · Cited by 33
Vistisen, S. T., Struijk, J. J., & LARSSON, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2008.01893.x · Cited by 32
Yazigi, A. G., Chouery, É., Hlais, S., Madi‐Jebara, S., Haddad, F., Hayek, G., & Jabbour, K. (2011) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2011.09.014 · Cited by 27
Cited by
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Vieillard-Baron, A., Matthay, M., Teboul, J. L., Bein, T., Schultz, M., Magder, S., & Marini, J. J. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4326-3 · Cited by 338
Less invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Shang, Y., Pan, C., Yang, X., Zhong, M., Shang, X., Wu, Z., Yu, Z., Zhang, W., Zhong, Q., Zheng, X., et al. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00689-1 · Cited by 247
Self-citationMyatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002183 · Cited by 236
Metadata
- Authors
- Yang, X., & Du, B.
- Venue
- Critical Care
- Published
- 2014-11-27
- Volume
- 18
- Issue
- 6
- Pages
- 650-650
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2084328514
- Cited by
- 258
- References
- 52
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.