CoChat

The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*

Myatra, Sheila Nainan, Prabu, Natesh R, Divatia, Jigeeshu Vasishtha, Monnet, Xavier, Kulkarni, Atul Prabhakar, Teboul, Jean-Louis · 2017 · Critical Care Medicine
Cited by 236

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Objectives: Stroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, “tidal volume challenge,” the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness. Design: Prospective, single-arm study. Setting: Medical-surgical ICU in a university hospital. Patients: Adult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation. Interventions: The pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/kg predicted body weight and 1 minute after the “tidal volume challenge.” The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight. Results: Thirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98–1.00) and 0.97 (0.92–1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mL/kg predicted body weight did not predict fluid responsiveness. Conclusions: The changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000002183

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 236

Metadata

Authors
Myatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L.
Venue
Critical Care Medicine
Published
2017-03
Volume
45
Issue
3
Pages
415-421
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2560370488
Cited by
236
References
26
FWCI
15.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*. https://app.cochat.ai/papers/10.1097/ccm.0000000000002183
The paper
Myatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L. (2017). The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000002183

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.