The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Objectives: Stroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, “tidal volume challenge,” the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness. Design: Prospective, single-arm study. Setting: Medical-surgical ICU in a university hospital. Patients: Adult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation. Interventions: The pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/kg predicted body weight and 1 minute after the “tidal volume challenge.” The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight. Results: Thirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98–1.00) and 0.97 (0.92–1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mL/kg predicted body weight did not predict fluid responsiveness. Conclusions: The changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationA trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationMarik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Cited by
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Self-citationPrediction of fluid responsiveness. What’s new?
Monnet, X., Shi, R., & Teboul, J.-L. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01022-8 · Cited by 249
“Moreover, the diagnostic thresholds differ slightly between the few available studies (Table 2), which in addition expressed the change in PPV either as an absolute value [30, 52, 65]} or as a percent change [56, 66, 67], or both [29].”
BackgroundMethodSelf-citationArterial Pulse Pressure Variation with Mechanical Ventilation
Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201801-0088ci · Cited by 200
“As mentioned above, this is a good indication of performing a VT challenge consisting of transiently increasing VT (from 6 to 8 mL/kg) and measuring the absolute changes in PPV (45, 46).”
BackgroundSelf-citationHow can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“Unavoidable measurement errors outweigh the benefit of direct estimation of stroke volume, so that PPV is preferred in adults.”
BackgroundSelf-citation
Metadata
- Authors
- Myatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2017-03
- Volume
- 45
- Issue
- 3
- Pages
- 415-421
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2560370488
- Cited by
- 236
- References
- 26
- FWCI
- 15.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*. https://app.cochat.ai/papers/10.1097/ccm.0000000000002183
- The paper
- Myatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L. (2017). The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000002183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.