The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The efficacy and safety of plasma exchange in patients with sepsis and septic shock: a systematic review and meta-analysis
Open accessAbstract
Introduction: Sepsis and septic shock are leading causes of intensive care unit (ICU) mortality. They are characterized by excessive inflammation, upregulation of procoagulant proteins and depletion of natural anticoagulants. Plasma exchange has the potential to improve survival in sepsis by removing inflammatory cytokines and restoring deficient plasma proteins. The objective of this study is to evaluate the efficacy and safety of plasma exchange in patients with sepsis. Methods: We searched MEDLINE, EMBASE, CENTRAL, Scopus, reference lists of relevant articles, and grey literature for relevant citations. We included randomized controlled trials comparing plasma exchange or plasma filtration with usual care in critically ill patients with sepsis or septic shock. Two reviewers independently identified trials, extracted trial-level data and performed risk of bias assessments using the Cochrane Risk of Bias tool. The primary outcome was all-cause mortality reported at longest follow-up. Meta-analysis was performed using a random-effects model. Results: Of 1,957 records identified, we included four unique trials enrolling a total of 194 patients (one enrolling adults only, two enrolling children only, one enrolling adults and children). The mean age of adult patients ranged from 38 to 53 years (n = 128) and the mean age of children ranged from 0.9 to 18 years (n = 66). All trials were at unclear to high risk of bias. The use of plasma exchange was not associated with a significant reduction in all-cause mortality (risk ratio (RR) 0.83, 95% confidence interval (CI) 0.45 to 1.52, I 2 60%). In adults, plasma exchange was associated with reduced mortality (RR 0.63, 95% CI 0.42 to 0.96; I 2 0%), but was not in children (RR 0.96, 95% CI 0.28 to 3.38; I 2 60%). None of the trials reported ICU or hospital lengths of stay. Only one trial reported adverse events associated with plasma exchange including six episodes of hypotension and one allergic reaction to fresh frozen plasma. Conclusions: Insufficient evidence exists to recommend plasma exchange as an adjunctive therapy for patients with sepsis or septic shock. Rigorous randomized controlled trials evaluating clinically relevant patient-centered outcomes are required to evaluate the impact of plasma exchange in this condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The epidemiology of sepsis in the United States from 1979 through 2000
Martin, G. S., Mannino, D. M., Eaton, S., & Moss, M. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022139 · Cited by 5,841
Blood Purification and Mortality in Sepsis: A Meta-Analysis of Randomized Trials*
Zhou, F., Peng, Z., Murugan, R., & Kellum, J. A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828cf412 · Cited by 189
Cited by
Weiss, S. L., Peters, M. J., Alhazzani, W., Agus, M. S. D., Flori, H. R., Inwald, D. P., Nadel, S., Schlapbach, L. J., Tasker, R. C., Argent, A. C., et al. (2020) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002198 · Cited by 1,228
Connelly‐Smith, L., Alquist, C. R., Aqui, N. A., Hofmann, J. C., Klingel, R., Onwuemene, O. A., Patriquin, C. J., Pham, H. P., Sanchez, A. P., Schneiderman, J., et al. (2023) · Journal of Clinical Apheresis · doi:10.1002/jca.22043 · Cited by 684
Weiss, S. L., Peters, M. J., Alhazzani, W., Agus, M. S. D., Flori, H. R., Inwald, D. P., Nadel, S., Schlapbach, L. J., Tasker, R. C., Argent, A. C., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05878-6 · Cited by 606
Sepsis-Associated Acute Kidney Injury
Alobaidi, R., Basu, R. K., Goldstein, S. L., & Bagshaw, S. M. (2015) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2015.01.002 · Cited by 374
Cytokine removal in human septic shock: Where are we and where are we going?
Honore, P. M., Hoste, E., Molnár, Z., Jacobs, R., Joannes-Boyau, O., Malbrain, M. L. N. G., & Forni, L. G. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0530-y · Cited by 192
Metadata
- Authors
- Rimmer, E., Houston, B. L., Kumar, A., Abou-Setta, A. M., Friesen, C., Marshall, J. C., Rock, G., Turgeon, A. F., Cook, D. J., Houston, D. S., & Zarychanski, R.
- Venue
- Critical Care
- Published
- 2014-12-20
- Volume
- 18
- Issue
- 6
- Pages
- 699-699
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W1977873442
- Cited by
- 181
- References
- 3
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The efficacy and safety of plasma exchange in patients with sepsis and septic shock: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s13054-014-0699-2
- The paper
- Rimmer, E., Houston, B. L., Kumar, A., Abou-Setta, A. M., Friesen, C., Marshall, J. C., Rock, G., Turgeon, A. F., Cook, D. J., Houston, D. S., & Zarychanski, R. (2014). The efficacy and safety of plasma exchange in patients with sepsis and septic shock: a systematic review and meta-analysis. Critical Care. https://doi.org/10.1186/s13054-014-0699-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.