A new two-tier strength assessment approach to the diagnosis of weakness in intensive care: an observational study
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Introduction: Intensive care unit-acquired weakness (ICU-AW) is a significant problem. There is currently widespread variability in the methods used for manual muscle testing and handgrip dynamometry (HGD) to diagnose ICU-AW. This study was conducted in two parts. The aims of this study were: to determine the inter-rater reliability and agreement of manual muscle strength testing using both isometric and through-range techniques using the Medical Research Council sum score and a new four-point scale, and to examine the validity of HGD and determine a cutoff score for the diagnosis of ICU-AW for the new four-point scale. Methods: Part one involved evaluation of muscle strength by two physical therapists in 29 patients ventilated >48 hours. Manual strength testing was performed by both physical therapists using two techniques: isometric and through range; and two scoring systems: traditional six-point Medical Research Council scale and a new collapsed four-point scale. Part two involved assessment of handgrip strength conducted on 60 patients. A cutoff score for ICU-AW was identified for the new four-point scoring system. Results: The incidence of ICU-AW was 42% (n = 25/60) in this study (based on HGD). In part one the highest reliability and agreement was observed for the isometric technique using the four-point scale (intraclass correlation coefficient = 0.90: kappa = 0.72 respectively). Differences existed between isometric and through-range scores (mean difference = 1.76 points, P = 0.005). In part two, HGD had a sensitivity of 0.88 and specificity of 0.80 for diagnosing ICU-AW. A cutoff score of 24 out of 36 points was identified for the four-point scale. Conclusions: The isometric technique is recommended with reporting on a collapsed four-point scale. Because HGD is easy to perform and sensitive, we recommend a new two-tier approach to diagnosing ICU-AW that first tests handgrip strength with follow-up strength assessment using the isometric technique for muscle strength testing if handgrip strength falls below cutoff scores. Whilst our results for the four-point scale are encouraging, further research is required to confirm the findings of this study and determine the validity of the four-point scoring system and cutoff score developed of less than 24 out of 36 before recommending adoption into clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Quality of Life Research · doi:10.1007/s11136-010-9606-8 · Cited by 4,260 · cited 2×
“The CONsensus-based Standards for the selection of health Measurement INstruments (COSMIN) guidelines [17] were followed in the reporting of the evaluation of the reliability and validity of measures.”
MethodBohannon, R. W., Peolsson, A., Massy-Westropp, N., Desrosiers, J., & Bear-Lehman, J. (2006) · Physiotherapy · doi:10.1016/j.physio.2005.05.003 · Cited by 598 · cited 2×
“Normative data on handgrip dynamometry are often stratified by gender and also age [23,32].”
MethodInter-rater reliability of manual muscle strength testing in ICU survivors and simulated patients
Fan, E., Ciesla, N. D., Truong, A. D., Bhoopathi, V., Zeger, S. L., & Needham, D. M. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1796-6 · Cited by 162
Cited by
Vanhorebeek, I., Latronico, N., & Van den Berghe, G. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-05944-4 · Cited by 717
The impact of extended bed rest on the musculoskeletal system in the critical care environment
Parry, S. M., & Puthucheary, Z. A. (2015) · Extreme Physiology & Medicine · doi:10.1186/s13728-015-0036-7 · Cited by 383
“A two-tier approach to screening for the presence of ICU-AW has been recommended involving (1) evaluation of handgrip strength and (2) manual muscle strength testing using an isometric approach with the Medical Research Council sum score [52].”
MethodSelf-citationESPEN guideline on clinical nutrition in hospitalized patients with acute or chronic kidney disease
Fiaccadori, E., Sabatino, A., Barazzoni, R., Carrero, J. J., Cupisti, A., De Waele, E., Jonckheer, J., Singer, P., & Cuerda, C. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2021.01.028 · Cited by 277
Muscular weakness and muscle wasting in the critically ill
Schefold, J. C., Wollersheim, T., Grunow, J. J., Luedi, M. M., Z'Graggen, W. J., & Weber‐Carstens, S. (2020) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12620 · Cited by 193
“This may (partly) allow for avoidance of risk factors and may support the prevention of worsening ICUAW.”
MethodInfluentialMayer, K. P., Thompson Bastin, M. L., Montgomery-Yates, A. A., Pastva, A. M., Dupont-Versteegden, E. E., Parry, S. M., & Morris, P. E. (2020) · Critical Care · doi:10.1186/s13054-020-03355-x · Cited by 176
“3 Handgrip strength of dominant hand was assessed at ICU discharge and hospital discharge using the Jamar hydraulic dynamometer (Sammons Preston Rolyan, Bolingbrook, IL, USA) with technique, position and cues previously described [37, 40].”
MethodSelf-citation
Metadata
- Authors
- Parry, S. M., Berney, S., Granger, C. L., Dunlop, D. L., Murphy, L., El-Ansary, D., Koopman, R., & Denehy, L.
- Venue
- Critical Care
- Published
- 2015-12
- Volume
- 19
- Issue
- 1
- Pages
- 52-52
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2015718765
- Cited by
- 123
- References
- 3
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.