Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress syndrome

Open access
Fanelli, Vito, Ranieri, Marco V., Mancebo, Jordi, Moerer, Onnen, Quintel, Michael, Morley, Scott, Moran, Indalecio, Parrilla, Francisco, Costamagna, Andrea, Gaudiosi, Marco, Combes, Alain · 2016 · Critical Care

Abstract

Background: Mechanical ventilation with a tidal volume (V T) of 6 mL/kg/predicted body weight (PBW), to maintain plateau pressure (P plat) lower than 30 cmH 2 O, does not completely avoid the risk of ventilator induced lung injury (VILI). The aim of this study was to evaluate safety and feasibility of a ventilation strategy consisting of very low V T combined with extracorporeal carbon dioxide removal (ECCO 2 R). Methods: In fifteen patients with moderate ARDS, V T was reduced from baseline to 4 mL/kg PBW while PEEP was increased to target a plateau pressure – (P plat) between 23 and 25 cmH 2 O. Low-flow ECCO 2 R was initiated when respiratory acidosis developed (pH < 7.25, PaCO 2 > 60 mmHg). Ventilation parameters (V T, respiratory rate, PEEP), respiratory compliance (C RS), driving pressure (DeltaP = V T/C RS), arterial blood gases, and ECCO 2 R system operational characteristics were collected during the period of ultra-protective ventilation. Patients were weaned from ECCO 2 R when PaO 2/FiO 2 was higher than 200 and could tolerate conventional ventilation settings. Complications, mortality at day 28, need for prone positioning and extracorporeal membrane oxygenation, and data on weaning from both MV and ECCO 2 R were also collected. Results: During the 2 h run in phase, V T reduction from baseline (6.2 mL/kg PBW) to approximately 4 mL/kg PBW caused respiratory acidosis (pH < 7.25) in all fifteen patients. At steady state, ECCO 2 R with an average blood flow of 435 mL/min and sweep gas flow of 10 L/min was effective at correcting pH and PaCO 2 to within 10 % of baseline values. PEEP values tended to increase at V T of 4 mL/kg from 12.2 to 14.5 cmH 2 O, but this change was not statistically significant. Driving pressure was significantly reduced during the first two days compared to baseline (from 13.9 to 11.6 cmH 2 O; p < 0.05) and there were no significant differences in the values of respiratory system compliance. Rescue therapies for life threatening hypoxemia such as prone position and ECMO were necessary in four and two patients, respectively. Only two study-related adverse events were observed (intravascular hemolysis and femoral catheter kinking). Conclusions: The low-flow ECCO 2 R system safely facilitates a low volume, low pressure ultra-protective mechanical ventilation strategy in patients with moderate ARDS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13054-016-1211-y

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 174

Metadata

Authors
Fanelli, V., Ranieri, M. V., Mancebo, J., Moerer, O., Quintel, M., Morley, S., Moran, I., Parrilla, F., Costamagna, A., Gaudiosi, M., & Combes, A.
Venue
Critical Care
Published
2016-02-10
Volume
20
Issue
1
Pages
36-36
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2255272767
Cited by
174
References
5
FWCI
20.92
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress syndrome. https://app.cochat.ai/papers/10.1186/s13054-016-1211-y
The paper
Fanelli, V., Ranieri, M. V., Mancebo, J., Moerer, O., Quintel, M., Morley, S., Moran, I., Parrilla, F., Costamagna, A., Gaudiosi, M., & Combes, A. (2016). Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress syndrome. Critical Care. https://doi.org/10.1186/s13054-016-1211-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.