Airway driving pressure and lung stress in ARDS patients
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Lung-protective ventilation strategy suggests the use of low tidal volume, depending on ideal body weight, and adequate levels of PEEP. However, reducing tidal volume according to ideal body weight does not always prevent overstress and overstrain. On the contrary, titrating mechanical ventilation on airway driving pressure, computed as airway pressure changes from PEEP to end-inspiratory plateau pressure, equivalent to the ratio between the tidal volume and compliance of respiratory system, should better reflect lung injury. However, possible changes in chest wall elastance could affect the reliability of airway driving pressure. The aim of this study was to evaluate if airway driving pressure could accurately predict lung stress (the pressure generated into the lung due to PEEP and tidal volume). METHODS: One hundred and fifty ARDS patients were enrolled. At 5 and 15 cmH2O of PEEP, lung stress, driving pressure, lung and chest wall elastance were measured. RESULTS: The applied tidal volume (mL/kg of ideal body weight) was not related to lung gas volume (r (2) = 0.0005 p = 0.772). Patients were divided according to an airway driving pressure lower and equal/higher than 15 cmH2O (the lower and higher airway driving pressure groups). At both PEEP levels, the higher airway driving pressure group had a significantly higher lung stress, respiratory system and lung elastance compared to the lower airway driving pressure group. Airway driving pressure was significantly related to lung stress (r (2) = 0.581 p < 0.0001 and r (2) = 0.353 p < 0.0001 at 5 and 15 cmH2O of PEEP). For a lung stress of 24 and 26 cmH2O, the optimal cutoff value for the airway driving pressure were 15.0 cmH2O (ROC AUC 0.85, 95 % CI = 0.782-0.922); and 16.7 (ROC AUC 0.84, 95 % CI = 0.742-0.936). CONCLUSIONS: Airway driving pressure can detect lung overstress with an acceptable accuracy. However, further studies are needed to establish if these limits could be used for ventilator settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 1×
“A receiver operating characteristics (ROC) curve was used to assess airway and transpulmonary driving pressure ability to predict a lung stress greater than 24 or 26 cmH2O [32].”
Method(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Acute Respiratory Distress Syndrome: The Berlin Definition
(2012) · JAMA · doi:10.1001/jama.2012.5669 · Cited by 8,731
Driving pressure and survival in the acute respiratory distress syndrome.
Amato, M. B. P., Meade, M. O., Slutsky, A. S., Brochard, L., Costa, E. L. V., Schoenfeld, D. A., Stewart, T. E., Briel, M., Talmor, D., Mercat, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmsa1410639 · Cited by 2,801 · cited 5×
“The whole population was divided in two groups according to the airway driving pressure lower and equal/higher than 15 cmH2O [3].”
BackgroundInfluential(2004) · New England Journal of Medicine · doi:10.1056/nejmoa032193 · Cited by 2,565 · cited 1×
“In addition, the selection of optimal PEEP level is still questionable [7, 18–23].”
BackgroundLung recruitment in patients with the acute respiratory distress syndrome.
Gattinoni, L., Caironi, P., Cressoni, M., Chiumello, D., Ranieri, V. M., Quintel, M., Russo, S., Patroniti, N., Cornejo, R., & Bugedo, G. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052052 · Cited by 1,548 · cited 3×
“Unlike healthy subjects, in ARDS patients the amount of lung gas volume in which the tidal volume is distributed is highly variable, and depends on the severity of the disease [25, 28].”
BackgroundMethodSelf-citationBriel, M., Meade, M., Mercat, A., Brower, R. G., Talmor, D., Walter, S. D., Slutsky, A. S., Pullenayegum, E., Zhou, Q., Cook, D., et al. (2010) · JAMA · doi:10.1001/jama.2010.218 · Cited by 1,467
Meade, M. O., Cook, D. J., Guyatt, G. H., Slutsky, A. S., Arabi, Y. M., Cooper, D. J., Davies, A. R., Hand, L. E., Zhou, Q., Thabane, L., et al. (2008) · JAMA · doi:10.1001/jama.299.6.637 · Cited by 1,370
Mercat, A., Richard, J.-C. M., Vielle, B., Jaber, S., Osman, D., Diehl, J.-L., Lefrant, J.-Y., Prat, G., Richecoeur, J., Nieszkowska, A., et al. (2008) · JAMA · doi:10.1001/jama.299.6.646 · Cited by 1,344
Mechanical ventilation guided by esophageal pressure in acute lung injury.
Talmor, D., Sarge, T., Malhotra, A., O'Donnell, C. R., Ritz, R., Lisbon, A., Novack, V., & Loring, S. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708638 · Cited by 1,149 · cited 1×
“Regarding the possibility that airway driving pressure could discriminate patients with lung overstress, although several studies titrated adjusted mechanical ventilation on the basis of lung stress, there is not a clear threshold at the present time; thus, in this study, two different cutoffs, 24 and 26 cmH2O of tran…”
BackgroundTidal Volume Reduction in Patients with Acute Lung Injury When Plateau Pressures Are Not High
Hager, D. N., Krishnan, J. A., Hayden, D. L., & Brower, R. G. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200501-048cp · Cited by 509
Cited by
Gorman, E. A., O’Kane, C. M., & McAuley, D. F. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01439-8 · Cited by 423
Pereira, S. M., Tucci, M. R., Morais, C. C. A., Simões, C. M., Tonelotto, B. F. F., Pompeo, M. S., Kay, F. U., Pelosi, P., Vieira, J. E., & Amato, M. B. P. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002435 · Cited by 307
on behalf of the investigators of the Acurasys and Proseva trials, Guérin, C., Papazian, L., Reignier, J., Ayzac, L., Loundou, A., & Forel, J.-M. (2016) · Critical Care · doi:10.1186/s13054-016-1556-2 · Cited by 266
Urner, M., Jüni, P., Hansen, B., Wettstein, M. S., Ferguson, N. D., & Fan, E. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30325-8 · Cited by 223
F ifty Y ears of R esearch in ARDS.Respiratory Mechanics in Acute Respiratory Distress Syndrome
Henderson, W. R., Chen, L., Amato, M. B. P., & Brochard, L. J. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201612-2495ci · Cited by 196
“Another study showed that ΔP and lung stress were closely related (79): a ΔP of 15 predicted a lung stress of 24 cm H2O, a level that has been associated with VILI (80–83).”
Background
Metadata
- Authors
- Chiumello, D., Carlesso, E., Brioni, M., & Cressoni, M.
- Venue
- Critical Care
- Published
- 2016-08-22
- Volume
- 20
- Issue
- 1
- Pages
- 276-276
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2509061560
- Cited by
- 213
- References
- 12
- FWCI
- 17.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.