Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 292

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Hemoadsorption by CytoSorb in septic patients: a case series

Open access
Kogelmann, Klaus, Jarczak, Dominik, Scheller, Morten, Drüner, Matthias·2017·Critical Care

Abstract

BACKGROUND: Septic shock, defined as life-threatening organ dysfunction caused by a dysregulated host response to infection, is a highly lethal condition that causes substantial morbidity and mortality among critically ill patients. One of the hallmarks of sepsis is the excessive release of cytokines and other inflammatory mediators causing refractory hypotension, tissue damage, metabolic acidosis and ultimately multiple organ failure. In this context, cytokine reduction by hemoadsorption represents a new concept for blood purification, developed to attenuate the overwhelming systemic levels of pro-inflammatory and anti-inflammatory mediators released in the early phase of sepsis. METHODS: In the present case series, we evaluated the impact of a new hemoadsorption device (CytoSorb) used as adjunctive therapy, on hemodynamics and clinically relevant outcome parameters in 26 critically ill patients with septic shock and in need of renal replacement therapy. RESULTS: We found that treatment of these patients with septic shock was associated with hemodynamic stabilization and a reduction in blood lactate levels. Actual mortality in the overall patient population was lower than mortality predicted by acute physiology and chronic health evaluation II (APACHE II). These effects seem to be more pronounced in patients in whom therapy started within 24 h of sepsis diagnosis, whereas a delay in the start of therapy was associated with a poor response to therapy in terms of reduction of catecholamine demand and survival. Moreover, from our patient population, medical patients seemed to benefit more than post-surgical patients in terms of survival. Treatment using the CytoSorb device was safe and well-tolerated with no device-related adverse events during or after the treatment sessions. CONCLUSION: Hemoadsorption using CytoSorb resulted in rapid hemodynamic stabilization and increased survival, particularly in patients in whom therapy was started early. Given the positive clinical experience of this case series, randomized controlled trials are urgently needed to define the potential benefits of this new treatment option.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13054-017-1662-9

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 292

Metadata

Authors
Kogelmann, K., Jarczak, D., Scheller, M., & Drüner, M.
Venue
Critical Care
Published
2017-03-27
Volume
21
Issue
1
Pages
74-74
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2601331348
Cited by
292
References
27
FWCI
20.59
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemoadsorption by CytoSorb in septic patients: a case series. https://app.cochat.ai/papers/10.1186/s13054-017-1662-9
The paper
Kogelmann, K., Jarczak, D., Scheller, M., & Drüner, M. (2017). Hemoadsorption by CytoSorb in septic patients: a case series. Critical Care. https://doi.org/10.1186/s13054-017-1662-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.