EXpert consensus On Diaphragm UltraSonography in the critically ill (EXODUS): a Delphi consensus statement on the measurement of diaphragm ultrasound-derived parameters in a critical care setting
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Background: Diaphragm ultrasonography is rapidly evolving in both critical care and research. Nevertheless, methodologically robust guidelines on its methodology and acquiring expertise do not, or only partially, exist. Therefore, we set out to provide consensus-based statements towards a universal measurement protocol for diaphragm ultrasonography and establish key areas for research. Methods: To formulate a robust expert consensus statement, between November 2020 and May 2021, a two-round, anonymous and online survey-based Delphi study among experts in the field was performed. Based on the literature review, the following domains were chosen: “Anatomy and physiology”, “Transducer Settings”, “Ventilator Impact”, “Learning and expertise”, “Daily practice” and “Future directions”. Agreement of ≥ 68% (≥ 10 panelists) was needed to reach consensus on a question. Results: Of 18 panelists invited, 14 agreed to participate in the survey. After two rounds, the survey included 117 questions of which 42 questions were designed to collect arguments and opinions and 75 questions aimed at reaching consensus. Of these, 46 (61%) consensus was reached. In both rounds, the response rate was 100%. Among others, there was agreement on measuring thickness between the pleura and peritoneum, using > 10% decrease in thickness as cut-off for atrophy and using 40 examinations as minimum training to use diaphragm ultrasonography in clinical practice. In addition, key areas for research were established. Conclusion: This expert consensus statement presents the first set of consensus-based statements on diaphragm ultrasonography methodology. They serve to ensure high-quality and homogenous measurements in daily clinical practice and in research. In addition, important gaps in current knowledge and thereby key areas for research are established. Trial registration The study was pre-registered on the Open Science Framework with registration digital object identifier https://doi.org/10.17605/OSF.IO/HM8UG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diamond, I. R., Grant, R. C., Feldman, B. M., Pencharz, P. B., Ling, S. C., Moore, A. M., & Wales, P. W. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.12.002 · Cited by 3,740
Consensus development methods, and their use in clinical guideline development.
Murphy, Black, Lamping, McKee, Sanderson, Askham, & Marteau (1998) · Health Technology Assessment · doi:10.3310/hta2030 · Cited by 2,051 · cited 1×
“This method was chosen as it serves to establish consensus on topics with unclear and/or conflicting evidence, while at the same time allowing exploration of fields beyond existing knowledge [19].”
MethodStability of response characteristics of a Delphi panel: application of bootstrap data expansion
Akins, R. B., Tolson, H., & Cole, B. R. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-37 · Cited by 994
Mechanical Ventilation–induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes
Goligher, E. C., Dres, M., Fan, E., Rubenfeld, G. D., Scales, D. C., Herridge, M. S., Vorona, S., Sklar, M. C., Rittayamai, N., Lanys, A., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0536oc · Cited by 813
Self-citationDiaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
Demoule, A., Jung, B., Prodanovic, H., Molinari, N., Chanques, G., Coirault, C., Matecki, S., Duguet, A., Similowski, T., & Jaber, S. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1668oc · Cited by 459
Self-citationGoligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448 · cited 1×
“In addition, we emphasize that this statement does not address the minimum number of examinations needed to obtain high reproducibility, which was demonstrated in a previous study, but the minimum training necessary for using diaphragm ultrasonography in clinical practice and guide decision-making [4].”
BackgroundSelf-citationLung- and Diaphragm-Protective Ventilation
Goligher, E. C., Dres, M., Patel, B. K., Sahetya, S. K., Beitler, J. R., Telias, I., Yoshida, T., Vaporidi, K., Grieco, D. L., Schepens, T., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202003-0655cp · Cited by 411
Self-citationDiaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
Self-citationZambon, M., Greco, M., Bocchino, S., Cabrini, L., Beccaria, P. F., & Zangrillo, A. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4524-z · Cited by 386 · cited 1×
“thickening fraction) and excursion during active breathing [1, 7, 8].”
BackgroundSelf-citationTwo‐dimensional ultrasound imaging of the diaphragm: Quantitative values in normal subjects
Boon, A. J., Harper, C. J., Shahgholi, L., Strommen, J. A., Watson, J. C., & Sorenson, E. J. (2013) · Muscle & Nerve · doi:10.1002/mus.23702 · Cited by 376 · cited 2×
“Even in healthy individuals, normal values have been shown to be highly variable and body position dependent [27, 32, 33].”
BackgroundUmbrello, M., Formenti, P., Longhi, D., Galimberti, A., Piva, I., Pezzi, A., Mistraletti, G., Marini, J. J., & Iapichino, G. (2015) · Critical Care · doi:10.1186/s13054-015-0894-9 · Cited by 343
Self-citationGoligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Self-citationDiaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306 · cited 1×
“While various cut-offs for thickening fraction as parameter for failing spontaneous breathing trials or extubation exist, the conducted studies vary strongly in terms of outcome definition and patient population [14, 18, 30, 31].”
BackgroundSelf-citationTuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z.-H., Goligher, E. C., Goffi, A., de Korte, C., Demoule, A., & Heunks, L. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 292
Self-citationHigher number of items associated with significantly lower response rates in COS Delphi surveys
Gargon, E., Crew, R., Burnside, G., & Williamson, P. R. (2019) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2018.12.010 · Cited by 224 · cited 2×
“A two-round survey was selected as appropriate method to form consensus, providing sufficient rounds to reach consensus without risking dropouts due to the extent of the survey [20].”
BackgroundMethodDubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209459 · Cited by 216
Self-citationPreregistering Qualitative Research: A Delphi Study
Haven, T. L., Errington, T. M., Gleditsch, K. S., van Grootel, L., Jacobs, A. M., Kern, F. G., Piñeiro, R., Rosenblatt, F., & Mokkink, L. B. (2020) · International Journal of Qualitative Methods · doi:10.1177/1609406920976417 · Cited by 211
Self-citationInability of Diaphragm Ultrasound to Predict Extubation Failure
Vivier, E., Muller, M., Putegnat, J.-B., Steyer, J., Barrau, S., Boissier, F., Bourdin, G., Mekontso-Dessap, A., Levrat, A., Pommier, C., et al. (2019) · Chest · doi:10.1016/j.chest.2019.03.004 · Cited by 179 · cited 1×
“While various cut-offs for thickening fraction as parameter for failing spontaneous breathing trials or extubation exist, the conducted studies vary strongly in terms of outcome definition and patient population [14, 18, 30, 31].”
BackgroundSelf-citationFarghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Standardization of Sonographic Diaphragm Thickness Evaluations in Healthy Volunteers
Carrillo-Esper, R., Pérez-Calatayud, Á. A., Arch-Tirado, E., Díaz-Carrillo, M. A., Aguirre, E. G., Velasco, R. T., Peña-Pérez, C. A., Monteros-Estrada, I. E. D. L., Meza-Márquez, J. M., Rivera, O. I. F., et al. (2016) · Respiratory Care · doi:10.4187/respcare.03999 · Cited by 147 · cited 1×
“Available evidence is scarce and only reflects local and not global thickness [27, 28].”
BackgroundUltrasound Imaging for Diaphragm Dysfunction: A Narrative Literature Review
Vetrugno, L., Guadagnin, G. M., Barbariol, F., Langiano, N., Zangrillo, A., & Bove, T. (2019) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.01.003 · Cited by 134 · cited 1×
“thickening fraction) and excursion during active breathing [1, 7, 8].”
BackgroundSelf-citationDres, M., Goligher, E. C., Dubé, B., Morawiec, É., Dangers, L., Reuter, D., Mayaux, J., Similowski, T., & Demoule, A. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0401-y · Cited by 120
Self-citationBoussuges, A., Rives, S., Finance, J., Chaumet, G., Vallée, N., Risso, J., & Brégeon, F. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.742703 · Cited by 96 · cited 1×
“Even in healthy individuals, normal values have been shown to be highly variable and body position dependent [27, 32, 33].”
BackgroundSelf-citationPositive end-expiratory pressure affects geometry and function of the human diaphragm
Jansen, D., Jonkman, A. H., de Vries, H. J., Wennen, M., Elshof, J., Hoofs, M. A., van den Berg, M., de Man, A., Keijzer, C., Scheffer, G., et al. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00184.2021 · Cited by 95 · cited 1×
“In this regard, clinicians are recommended to appreciate the measurements in the light of the impact of positive end expiratory pressure on measurements, through diminished excursion and higher resting thickness due to the lower resting position [36].”
BackgroundSelf-citationComparison of Diaphragm Thickness Measurements Among Postures Via Ultrasound Imaging
Hellyer, N. J., Andreas, N. M., Bernstetter, A., Cieslak, K. R., Donahue, G. F., Steiner, E. A., Hollman, J. H., & Boon, A. J. (2016) · PM&R · doi:10.1016/j.pmrj.2016.06.001 · Cited by 76 · cited 1×
“Even in healthy individuals, normal values have been shown to be highly variable and body position dependent [27, 32, 33].”
BackgroundGrant, S., Booth, M., & Khodyakov, D. (2018) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2018.03.007 · Cited by 73
Garofalo, E., Bruni, A., Pelaia, C., Landoni, G., Zangrillo, A., Antonelli, M. M., Conti, G., Biasucci, D. G., Mercurio, G., Cortegiani, A., et al. (2019) · The Ultrasound Journal · doi:10.1186/s13089-019-0137-4 · Cited by 50 · cited 1×
“However, the consensus reached poses a general statement that does not take prior ultrasound experience into account [37].”
BackgroundSelf-citationCappellini, I., Picciafuochi, F., Bartolucci, M., Matteini, S., Virgili, G., & Adembri, C. (2020) · Journal of Ultrasound · doi:10.1007/s40477-020-00462-x · Cited by 44 · cited 1×
“For now, there is no evidence favouring either method and no clear advantages are directly apparent [34, 35].”
BackgroundDiaphragm echodensity in mechanically ventilated patients: a description of technique and outcomes
Coiffard, B., Riegler, S., Sklar, M. C., Dres, M., Vorona, S., Reid, W. D., Brochard, L. J., Ferguson, N. D., & Goligher, E. C. (2021) · Critical Care · doi:10.1186/s13054-021-03494-9 · Cited by 40 · cited 1×
“In this regard, evaluating the echogenicity of the diaphragm, and thereby potentially quality of the diaphragm, was agreed to be an area of special interest for future research [26].”
BackgroundSelf-citationWeaning the patient: between protocols and physiology
Haaksma, M. E., Tuinman, P. R., & Heunks, L. M. A. (2020) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000790 · Cited by 30 · cited 1×
“thickening fraction) and excursion during active breathing [1, 7, 8].”
BackgroundSelf-citationHolistic Ultrasound to Predict Extubation Failure in Clinical Practice
Haaksma, M. E., Smit, J. M., Heldeweg, M. L. A., Nooitgedacht, J. S., Atmowihardjo, L. N., Jonkman, A. H., de Vries, H. J., Lim, E. H. T., Steenvoorden, T. S., Lust, E. J., et al. (2021) · Respiratory Care · doi:10.4187/respcare.08679 · Cited by 28
Self-citationDoes it make difference to measure diaphragm function with M mode (MM) or B mode (BM)?
Kalın, B. S., & Gürsel, G. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00432-7 · Cited by 19 · cited 1×
“For now, there is no evidence favouring either method and no clear advantages are directly apparent [34, 35].”
Background
Metadata
- Authors
- Haaksma, M. E., Smit, J. M., Boussuges, A., Demoule, A., Dres, M., Ferrari, G., Formenti, P., Goligher, E. C., Heunks, L., Lim, E. H. T., Mokkink, L. B., Soilemezi, E., Shi, Z., Umbrello, M., Vetrugno, L., Vivier, E., Xu, L., Zambon, M., & Tuinman, P. R.
- Venue
- Critical Care
- Published
- 2022-04-08
- Volume
- 26
- Issue
- 1
- Pages
- 99-99
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W4223486196
- Cited by
- 205
- References
- 33
- FWCI
- 30.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.